New generation TruMicro series 2000: Micromachining versatility by GHz-burst, higher average power, flexible pulse on demand and integrated hollow-core fiber interface

Author(s):  
Axel Fehrenbacher ◽  
Marc Sailer ◽  
Benjamin Fuehra ◽  
Florian Jansen ◽  
Chuong Tan ◽  
...  
Author(s):  
Martin Gebhardt ◽  
Christian Gaida ◽  
Fabian Stutzki ◽  
Cesar Jauregui ◽  
Jose Antonio-Lopez ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pablo Roldán-Varona ◽  
Rosa Ana Pérez-Herrera ◽  
Luis Rodríguez-Cobo ◽  
Luis Reyes-González ◽  
Manuel López-Amo ◽  
...  

AbstractIn this work, a novel optical fiber sensor capable of measuring both the liquid level and its refractive index is designed, manufactured and demonstrated through simulations and experimentally. For this, a silica capillary hollow-core fiber is used. The fiber, with a sensing length of 1.55 mm, has been processed with a femtosecond laser, so that it incorporates four holes in its structure. In this way, the liquid enters the air core, and it is possible to perform the sensing through the Fabry–Perot cavities that the liquid generates. The detection mode is in reflection. With a resolution of 4 μm (liquid level), it is in the state of the art of this type of sensor. The system is designed so that in the future it will be capable of measuring the level of immiscible liquids, that is, liquids that form stratified layers. It can be useful to determine the presence of impurities in tanks.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 478
Author(s):  
Yudai Kudo ◽  
Saiko Kino ◽  
Yuji Matsuura

Human breath is a biomarker of body fat metabolism and can be used to diagnose various diseases, such as diabetes. As such, in this paper, a vacuum ultraviolet (VUV) spectroscopy system is proposed to measure the acetone in exhaled human breath. A strong absorption acetone peak at 195 nm is detected using a simple system consisting of a deuterium lamp source, a hollow-core fiber gas cell, and a fiber-coupled compact spectrometer corresponding to the VUV region. The hollow-core fiber functions both as a long-path and an extremely small-volume gas cell; it enables us to sensitively measure the trace components of exhaled breath. For breath analysis, we apply multiple regression analysis using the absorption spectra of oxygen, water, and acetone standard gas as explanatory variables to quantitate the concentration of acetone in breath. Based on human breath, we apply the standard addition method to obtain the measurement accuracy. The results suggest that the standard deviation is 0.074 ppm for healthy human breath with an acetone concentration of around 0.8 ppm and a precision of 0.026 ppm. We also monitor body fat burn based on breath acetone and confirm that breath acetone increases after exercise because it is a volatile byproduct of lipolysis.


Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1220
Author(s):  
Chee Wei Lee ◽  
Stuart Madnick

Urban mobility is in the midst of a revolution, driven by the convergence of technologies such as artificial intelligence, on-demand ride services, and Internet-connected and self-driving vehicles. Technological advancements often lead to new hazards. Coupled with the increased levels of automation and connectivity in the new generation of autonomous vehicles, cybersecurity is emerging as a key threat affecting these vehicles. Traditional hazard analysis methods treat safety and security in isolation and are limited in their ability to account for interactions among organizational, sociotechnical, human, and technical components. In response to these challenges, the cybersafety method, based on System Theoretic Process Analysis (STPA and STPA-Sec), was developed to meet the growing need to holistically analyze complex sociotechnical systems. We applied cybersafety to coanalyze safety and security hazards, as well as identify mitigation requirements. The results were compared with another promising method known as Combined Harm Analysis of Safety and Security for Information Systems (CHASSIS). Both methods were applied to the Mobility-as-a-Service (MaaS) and Internet of Vehicles (IoV) use cases, focusing on over-the-air software updates feature. Overall, cybersafety identified additional hazards and more effective requirements compared to CHASSIS. In particular, cybersafety demonstrated the ability to identify hazards due to unsafe/unsecure interactions among sociotechnical components. This research also suggested using CHASSIS methods for information lifecycle analysis to complement and generate additional considerations for cybersafety. Finally, results from both methods were backtested against a past cyber hack on a vehicular system, and we found that recommendations from cybersafety were likely to mitigate the risks of the incident.


2020 ◽  
pp. 1-1
Author(s):  
Antonino Nespola ◽  
Stefano Straullu ◽  
Thomas D. Bradley ◽  
Kerrianne Harrington ◽  
Hesham Sakr ◽  
...  
Keyword(s):  

2021 ◽  
Vol 103 (6) ◽  
Author(s):  
Thorsten Peters ◽  
Leonid P. Yatsenko ◽  
Thomas Halfmann

2017 ◽  
Vol 402 ◽  
pp. 695-698
Author(s):  
Min-Hwan Lee ◽  
Sung-Hyun Kim ◽  
Eun-Sun Kim ◽  
In-Kag Hwang

Sign in / Sign up

Export Citation Format

Share Document