scholarly journals BepiColombo MIXS focal plane assembly: from concept design to proto-flight model

Author(s):  
Jose L. San Juan ◽  
Javier Serrano ◽  
Stéphane Gallet
Author(s):  
C. Williges ◽  
R. Hohn ◽  
H. Rossmann ◽  
S. Hilbert ◽  
M. Uhlig ◽  
...  

The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR) in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS) on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs), one for the UV-VIS spectral range (305 nm … 500 nm), the second for NIR (750 nm … 775 nm). In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM) which will also be used for the upcoming Flight Model (FM) verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source.<br><br> The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.


Author(s):  
Alan Boyde ◽  
Milan Hadravský ◽  
Mojmír Petran ◽  
Timothy F. Watson ◽  
Sheila J. Jones ◽  
...  

The principles of tandem scanning reflected light microscopy and the design of recent instruments are fully described elsewhere and here only briefly. The illuminating light is intercepted by a rotating aperture disc which lies in the intermediate focal plane of a standard LM objective. This device provides an array of separate scanning beams which light up corresponding patches in the plane of focus more intensely than out of focus layers. Reflected light from these patches is imaged on to a matching array of apertures on the opposite side of the same aperture disc and which are scanning in the focal plane of the eyepiece. An arrangement of mirrors converts the central symmetry of the disc into congruency, so that the array of apertures which chop the illuminating beam is identical with the array on the observation side. Thus both illumination and “detection” are scanned in tandem, giving rise to the name Tandem Scanning Microscope (TSM). The apertures are arranged on Archimedean spirals: each opposed pair scans a single line in the image.


Author(s):  
Malcolm Brown ◽  
Reynolds M. Delgado ◽  
Michael J. Fink

While light microscopy has been used to image sub-micron objects, numerous problems with diffraction-limitations often preclude extraction of useful information. Using conventional dark-field and phase contrast light microscopy coupled with image processing, we have studied the following objects: (a) polystyrene beads (88nm, 264nm, and 557mn); (b) frustules of the diatom, Pleurosigma angulatum, and the T-4 bacteriophage attached to its host, E. coli or free in the medium. Equivalent images of the same areas of polystyrene beads and T-4 bacteriophages were produced using transmission electron microscopy.For light microscopy, we used a Zeiss universal microscope. For phase contrast observations a 100X Neofluar objective (N.A.=1.3) was applied. With dark-field, a 100X planachromat objective (N.A.=1.25) in combination with an ultra-condenser (N.A.=1.25) was employed. An intermediate magnifier (Optivar) was available to conveniently give magnification settings of 1.25, 1.6, and 2.0. The image was projected onto the back focal plane of a film or television camera with a Carl Zeiss Jena 18X Compens ocular.


2001 ◽  
Vol 7 (S2) ◽  
pp. 148-149
Author(s):  
C.D. Poweleit ◽  
J Menéndez

Oil immersion lenses have been used in optical microscopy for a long time. The light’s wavelength is decreased by the oil’s index of refraction n and this reduces the minimum spot size. Additionally, the oil medium allows a larger collection angle, thereby increasing the numerical aperture. The SIL is based on the same principle, but offers more flexibility because the higher index material is solid. in particular, SILs can be deployed in cryogenic environments. Using a hemispherical glass the spatial resolution is improved by a factor n with respect to the resolution obtained with the microscope’s objective lens alone. The improvement factor is equal to n2 for truncated spheres.As shown in Fig. 1, the hemisphere SIL is in contact with the sample and does not affect the position of the focal plane. The focused rays from the objective strike the lens at normal incidence, so that no refraction takes place.


Author(s):  
A.N. Shishkin ◽  
◽  
E.O. Timashev ◽  
V.I. Solovykh ◽  
M.G. Volkov ◽  
...  

1993 ◽  
Author(s):  
E. Boughan ◽  
J. Doty ◽  
R. Foster ◽  
N. Tyce
Keyword(s):  

2021 ◽  
Author(s):  
Joseph Gonzales ◽  
Daiki Kurihara ◽  
Hiroki Nagai ◽  
Hirotaka Sakaue ◽  
Aleksandar Jemcov

Sign in / Sign up

Export Citation Format

Share Document