1 μm spatial resolution in silicon photon-counting CT detectors by measuring charge diffusion

Author(s):  
Christel Sundberg ◽  
Mats Persson ◽  
J. Jacob Wikner ◽  
Mats Danielsson
2021 ◽  
pp. 1-13
Author(s):  
Muhammad U. Ghani ◽  
Farid H. Omoumi ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Bin Zheng ◽  
...  

PURPOSE: To compare imaging performance of a cadmium telluride (CdTe) based photon counting detector (PCD) with a CMOS based energy integrating detector (EID) for potential phase sensitive imaging of breast cancer. METHODS: A high energy inline phase sensitive imaging prototype consisting of a microfocus X-ray source with geometric magnification of 2 was employed. The pixel pitch of the PCD was 55μm, while 50μm for EID. The spatial resolution was quantitatively and qualitatively assessed through modulation transfer function (MTF) and bar pattern images. The edge enhancement visibility was assessed by measuring edge enhancement index (EEI) using the acrylic edge acquired images. A contrast detail (CD) phantom was utilized to compare detectability of simulated tumors, while an American College of Radiology (ACR) accredited phantom for mammography was used to compare detection of simulated calcification clusters. A custom-built phantom was employed to compare detection of fibrous structures. The PCD images were acquired at equal, and 30% less mean glandular dose (MGD) levels as of EID images. Observer studies along with contrast to noise ratio (CNR) and signal to noise ratio (SNR) analyses were performed for comparison of two detection systems. RESULTS: MTF curves and bar pattern images revealed an improvement of about 40% in the cutoff resolution with the PCD. The excellent spatial resolution offered by PCD system complemented superior detection of the diffraction fringes at boundaries of the acrylic edge and resulted in an EEI value of 3.64 as compared to 1.44 produced with EID image. At MGD levels (standard dose), observer studies along with CNR and SNR analyses revealed a substantial improvement of PCD acquired images in detection of simulated tumors, calcification clusters, and fibrous structures. At 30% less MGD, PCD images preserved image quality to yield equivalent (slightly better) detection as compared to the standard dose EID images. CONCLUSION: CdTe-based PCDs are technically feasible to image breast abnormalities (low/high contrast structures) at low radiation dose levels using the high energy inline phase sensitive imaging technique.


2020 ◽  
Author(s):  
Matteo Battisti ◽  
Enrico Arnone ◽  
Mario Bertaina ◽  
Marco Casolino ◽  
Olivier Chanrion ◽  
...  

<p>The search for the physical mechanisms of lightning, transient luminous events and terrestrial gamma-ray flashes is receiving an extraordinary support by new space observations that have recently become available. Next to lightning detectors on geostationary satellites, new low orbit experiments are giving an unprecedented insight in the very source of these processes. Looking at the physics behind these new observations requires however to have a variety of different instruments covering the same event, and this is proving extremely challenging. Here, we present observations of UV emissions of elves and lightning taken for the first time simultaneously from the two instruments Mini-EUSO and ASIM operating on the international space station. Mini-EUSO was designed to perform observations of the UV-light night emission from Earth. It is a wide field of view telescope (44°x44° square FOV) installed for the first time on October 2019 inside the Zvezda Module of the ISS, looking nadir through a UV transparent window. Its optical system consists of two Fresnel lenses for light collection. The light is focused onto an array of 36 multi-anode photomultiplier tubes (MAPMT), for a total of 2304 pixels. Each pixel has a footprint on ground of ~5.5 km. The instrument is capable of single-photon counting on three different timescales: a 2.5 microsecond (D1) and a 320 microsecond (D2) timescale with a dedicated trigger system, and a 40.96ms timescale (D3) used to produce a continuous monitoring of the UV emission from the Earth. ASIM is an experiment dedicated to lightning and atmospheric processes. Its Modular Multispectral Imaging Array (MMIA) is made of an array of 3 high speed photometers probing different wavelength sampling at rates up to 100 kHz, and 2 Electron Multiplication Charge Coupled Devices (EM-CCDs) with a sub-km spatial resolution with an 80° FOV and recording up to 12 frames per second. Mini-EUSO detected several bright atmospheric events like lightning and elves, with a few km spatial resolution and different time resolutions, probing therefore different stages of the electromagnetic phenomena. Observations from Mini-EUSO were simultaneously captured by ASIM instruments, allowing for the first time to compare and complement the capabilities of the two instruments with a time inter-calibration based on unambiguous series of lightning detections.</p>


2003 ◽  
Author(s):  
Anton S. Tremsin ◽  
John V. Vallerga ◽  
Oswald H. W. Siegmund ◽  
Jeff S. Hull

Author(s):  
Octavian Maciu ◽  
Wilfried Uhring ◽  
Jean-Baptiste Kammerer ◽  
Jean-Pierre Le Normand ◽  
Norbert Dumas ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document