Fiber-optics: a new route towards ultra-low detection limit label-free biosensing

Author(s):  
Pablo Zubiate ◽  
Desiree Santano ◽  
Aitor Urrutia ◽  
Carlos R. Zamarreño ◽  
Silvia Díaz ◽  
...  
2021 ◽  
Vol 13 (15) ◽  
pp. 1832-1838
Author(s):  
Jiaxi Cheng ◽  
Fenghua Jiang ◽  
Siqi Zhang

We develop a label-free, sensitive and selective nanochannel sensing platform for detection of TC. The nanosensor provided a low detection limit, a wide detection range and excellent recovery rate in different water samples.


The Analyst ◽  
2014 ◽  
Vol 139 (13) ◽  
pp. 3347-3351 ◽  
Author(s):  
Chia-Chen Chang ◽  
Chen-Yu Chen ◽  
Xihong Zhao ◽  
Tzu-Heng Wu ◽  
Shih-Chung Wei ◽  
...  

A simple design of a label-free colorimetric assay for IgE was demonstrated based on a structure-switching aptamer with a low detection limit of 0.2 nM and high selectivity.


Author(s):  
J. J. Domanski ◽  
P. L. Haire ◽  
T.J. Sheets

AbstractAverage residue Ievels of DDT + TDE in flue-cured tobacco decreased from 6.1 ppm in 1970 to 0.85 ppm in 1972. DDT + TDE residues in Burley also dropped sharply from previous levels. In 1972 one sample from Kentucky contained 8.17 ppm; all other Burley samples were less than 0.25 ppm. DDT + TDE residues also declined in fire-cured and air-cured types; of these samples Tennessee dark air-cured tobacco contained the highest average residue (3.5 ppm of DDT + TDE). In 1972 over 90 % of the flue-cured samples were positive for toxaphene. Since each of our samples was a composite of tobacco from 10 farmers, we cannot conclude from this result that 90 % of the individual piles contained toxaphene. Significant amounts of toxaphene were found in other types also; for example, 50 % of the 1972 Burley samples had toxaphene concentrations greater than 0.5 ppm. Average endosulfan levels decreased between 1970 and 1972 in flue-cured and Burley tobaccos. However, in all of the dark air and dark fire-cured samples from Tennessee endosulfan residues exceeded 5 ppm. Average endrin residues were at or near the low detection limit in alI samples except fire-cured and dark air-cured tobacco from Tennessee; these averaged 0.26 and 0.17 ppm, respectively.


2019 ◽  
Vol 15 (4) ◽  
pp. 502-510 ◽  
Author(s):  
Hakan Karadeniz ◽  
Arzum Erdem

Background: Anthrax Lethal Factor (ANT) is the dominant virulence factor produced by B. anthracis and is the major cause of death of infected animals. In this paper, pencil graphite electrodes GE were modified with single-walled and multi-walled carbon nanotubes (CNTs) for the detection of hybridization related to the ANT DNA for the first time in the literature. Methods: The electrochemical monitoring of label-free DNA hybridization related to ANT DNA was explored using both SCNT and MCNT modified PGEs with differential pulse voltammetry (DPV). The performance characteristics of ANT-DNA hybridization on disposable GEs were explored by measuring the guanine signal in terms of optimum analytical conditions; the concentration of SCNT and MCNT, the concentrations of probe and target, and also the hybridization time. Under the optimum conditions, the selectivity of probe modified electrodes was tested and the detection limit was calculated. Results: The selectivity of ANT probes immobilized onto MCNT-GEs was tested in the presence of hybridization of probe with NC no response was observed and with MM, smaller responses were observed in comparison to full-match DNA hybridization case. Even though there are unwanted substituents in the mixture samples containing both the target and NC in the ratio 1:1 and both the target and MM in the ratio 1:1, it has been found that ANT probe immobilized CNT modified graphite sensor can also select its target by resulting with 20.9% decreased response in comparison to the one measured in the case of full-match DNA hybridization case Therefore, it was concluded that the detection of direct DNA hybridization was performed by using MCNT-GEs with an acceptable selectivity. Conclusion: Disposable SCNT/MCNT modified GEs bring some important advantages to our assay including easy use, cost-effectiveness and giving a response in a shorter time compared to unmodified PGE, carbon paste electrode and glassy carbon electrode developed for electrochemical monitoring of DNA hybridization. Consequently, the detection of DNA hybridization related to the ANT DNA by MCNT modified sensors was performed by using lower CNT, probe and target concentrations, in a shorter hybridization time and resulting in a lower detection limit according to the SCNT modified sensors. In conclusion, MCNT modified sensors can yield the possibilities leading to the development of nucleic acid sensors platforms for the improvement of fast and cost-effective detection systems with respect to DNA chip technology.


2021 ◽  
Author(s):  
Bo Liu ◽  
Luanying Yang ◽  
Gang Wang ◽  
Sha He ◽  
Xiaobo Wang ◽  
...  

A simple and low-cost electrochemical CEA immunosensor was investigated via the self-polymerization of dopamine and a dithiol compound spacer for the covalent immobilization of antibodies. The designed CEA immunosensor exhibited a linear response and a low detection limit.


Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2016 ◽  
Vol 18 (34) ◽  
pp. 23795-23802 ◽  
Author(s):  
Xiaolong Wang ◽  
Lu Zhou ◽  
Wei Lai ◽  
Tao Jiang ◽  
Jun Zhou

We present a recyclable SERS-based immunoassay for CA19-9 with a low detection limit of 5 U mL−1. The linking between TiO2-NTs and 4MBA was destroyed by catalyzing 4MBA into 4-sulfobenzoate upon UV irradiation, which was clarified by UPLC/ESI-tqMS and density functional theory.


RSC Advances ◽  
2016 ◽  
Vol 6 (3) ◽  
pp. 1722-1728 ◽  
Author(s):  
Pankaj Gupta ◽  
Munetaka Oyama ◽  
Rajendra N. Goyal

Electrochemical oxidation of 8-hydroxydeoxyguanosine (8-OHdG) and its detection with low detection limit is reported at pyrolytic graphite electrode.


The Analyst ◽  
2015 ◽  
Vol 140 (10) ◽  
pp. 3557-3564 ◽  
Author(s):  
Yaoguang Wang ◽  
Yueyun Li ◽  
Hongmin Ma ◽  
Aiping Guo ◽  
Bin Du ◽  
...  

An ultrasensitive electrochemical immunosensor was developed for detecting CD146. rGO-TEPA enhanced the loading capacity of Ab1 and facilitated the electron transfer. Au and Pd nanoparticles on the TiO2 colloidal sphere facilitated the decomposition of H2O2. The immunosensor exhibited an extremely low detection limit of 1.6 pg mL−1 for CD146.


Sign in / Sign up

Export Citation Format

Share Document