Visualisation of biological tissues with the use of LED source illumination

Author(s):  
Lukasz Gryko ◽  
Urszula Blaszczak ◽  
Jakub Lewandowski ◽  
Andrzej Zajac
2020 ◽  
Vol 12 ◽  
Author(s):  
Ritesh Kumar Singh ◽  
Adarsh Chandra Mishra ◽  
Pooja Lohia ◽  
D.K. Dwivedi

Background: Refractive index determination of biological tissues is a challenging issue. Many biological species also show vibrational signature in infrared domain. The chalcogenide-based glasses can be used to make the fiber optic evanescent wave sensors for detection of analyte. Objectives: The primary objective is to study the effect of various parameters on the sensitivity of chalcogenide glass-based evanescent wave sensor for biological tissue detection. Methods: An evanescent wave sensor has been proposed with collimated source illumination and uniform tapering. The chalcogenide materials are chosen such that the weakly guiding approximation could be followed. Complex refractive indices of liver tissue samples have been taken for the analysis of sensitivity via method of evanescent absorption coefficient. Equations for sensitivity have been solved analytically using MATLAB software. Results: The simplification of the formula for sensitivity leads to the inference that the sensitivity is a function of core radius, refractive indices of sample tissues and wavelength used. Moreover, since the refractive indices of the materials are also a function of temperature, therefore a change in temperature results into change in the profile of guiding mode. Hence the effect of temperature must also be observed. The initial simulation parameters are taken; core radius 100 µm, sensing length 4 cm and wavelength 1.0 µm. In the NIR region we have a better sensitivity of detection for all the tissues samples and the risk of photodamage of the biosamples is reduced to a good extent. It has been found that sensitivity decreases with wavelength and core radius whereas increases with temperature. It has also been shown that sensitivity is found to be better with collimated in comparison with diffused source. Conclusion: The comparative study results that one should operate at shorter NIR region of wavelength for higher sensitivity. The collimated source illumination should be preferred over diffused one for launching the light within the fiber to have high sensitivity. Further, length of sensing region should be larger but the fiber core radius should be smaller. The proposed biosensor is robust and can also be used many times if the probe (sensing region) is cleaned properly. Moreover, a small amount of analyte is enough for the detection. Thus, the proposed sensor is very useful for bio-medical applications with its high performance, accuracy and robustness.


Author(s):  
Lee D. Peachey ◽  
Clara Franzini-Armstrong

The effective study of biological tissues in thick slices of embedded material by high voltage electron microscopy (HVEM) requires highly selective staining of those structures to be visualized so that they are not hidden or obscured by other structures in the image. A tilt pair of micrographs with subsequent stereoscopic viewing can be an important aid in three-dimensional visualization of these images, once an appropriate stain has been found. The peroxidase reaction has been used for this purpose in visualizing the T-system (transverse tubular system) of frog skeletal muscle by HVEM (1). We have found infiltration with lanthanum hydroxide to be particularly useful for three-dimensional visualization of certain aspects of the structure of the T- system in skeletal muscles of the frog. Specifically, lanthanum more completely fills the lumen of the tubules and is denser than the peroxidase reaction product.


Author(s):  
William H. Massover

Stereoscopic examination of thick sections of fixed and embedded biological tissues by high voltage electron microscopy has been shown to allow direct visualization of three-dimensional fine structure. The present report will consider the occurrence of some new technical problems in specimen preparation and Image interpretation that are not common during lower voltage studies of thin sections.Thick Sectioning and Tissue Coloration - Epon sections of 0.5 μm or more that are cut with glass knives do not have a uniform thickness as Judged by their interference colors; these colors change with time during their flotation on the knife bath, and again when drying onto the specimen support. Quoted thicknesses thus must be considered only as rough estimates unless measured in specific regions by other methods. Chloroform vapors do not always result in good spreading of thick sections; however, they will spread spontaneously to large degrees after resting on the flotation bath for several minutes. Ribbons of thick sections have been almost impossible to obtain.


Author(s):  
C.A. Baechler ◽  
W. C. Pitchford ◽  
J. M. Riddle ◽  
C.B. Boyd ◽  
H. Kanagawa ◽  
...  

Preservation of the topographic ultrastructure of soft biological tissues for examination by scanning electron microscopy has been accomplished in the past by using lengthy epoxy infiltration techniques, or dehydration in ethanol or acetone followed by air drying. Since the former technique requires several days of preparation and the latter technique subjects the tissues to great stress during the phase change encountered during air-drying, an alternate rapid, economical, and reliable method of surface structure preservation was developed. Turnbill and Philpott had used a fluorocarbon for the critical point drying of soft tissues and indicated the advantages of working with fluids having both moderately low critical pressures as well as low critical temperatures. Freon-116 (duPont) which has a critical temperature of 19. 7 C and a critical pressure of 432 psi was used in this study.


Author(s):  
Bruno Schueler ◽  
Robert W. Odom

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) provides unique capabilities for elemental and molecular compositional analysis of a wide variety of surfaces. This relatively new technique is finding increasing applications in analyses concerned with determining the chemical composition of various polymer surfaces, identifying the composition of organic and inorganic residues on surfaces and the localization of molecular or structurally significant secondary ions signals from biological tissues. TOF-SIMS analyses are typically performed under low primary ion dose (static SIMS) conditions and hence the secondary ions formed often contain significant structural information.This paper will present an overview of current TOF-SIMS instrumentation with particular emphasis on the stigmatic imaging ion microscope developed in the authors’ laboratory. This discussion will be followed by a presentation of several useful applications of the technique for the characterization of polymer surfaces and biological tissues specimens. Particular attention in these applications will focus on how the analytical problem impacts the performance requirements of the mass spectrometer and vice-versa.


2014 ◽  
Vol 59 (12) ◽  
pp. 1149-1154
Author(s):  
A.D. Mamuta ◽  
◽  
V.S. Voitsekhovich ◽  
N.M. Kachalova ◽  
L.F. Golovko ◽  
...  

2015 ◽  
Vol 18 (1) ◽  
pp. 57-69 ◽  
Author(s):  
Hossein Askarizadeh ◽  
Hossein Ahmadikia

2018 ◽  
Vol 17 (2) ◽  
pp. 84-91 ◽  
Author(s):  
G. V. Papayan ◽  
A. L. Akopov ◽  
P. A. Antonyan ◽  
A. A. Ilin ◽  
N. N. Petrishchev

Introduction. Near infrared (NIR) fluorescent diagnostics is promising due to a deeper penetration into biological tissues. Material and methods. In experiments on rabbits and in clinical studies evaluation the lymphatic system with the use of the instrument complex FLUM-808 was analysed. Results. For visualization of the lymphatic vessels of the skin, the intradermal administration of ICG, dissolved in 20 % albumin in the order of 0.02 mg/ml, is optimal. Peritumoral injection of ICG allows visualizing sentinel lymph nodes in patients with lung cancer. Conclusions. The developed NIR fluorescence diagnostic system FLUM-808 allows to real time visualization of lymphatic vessels and lymph nodes.


Sign in / Sign up

Export Citation Format

Share Document