In vivo demonstration of real-time oxygen saturation imaging using a portable and affordable LED-based multispectral photoacoustic and ultrasound imaging system

Author(s):  
Mithun Kuniyil Ajith Singh ◽  
Naoto Sato ◽  
Yoshiyuki Sankai ◽  
Fumiyuki Ichihashi
2018 ◽  
Vol 39 (1) ◽  
pp. 11-16
Author(s):  
Toshitaka Agano ◽  
Naoto Sato ◽  
Yusuke Shigeta ◽  
Tetsuji Uemura ◽  
Kunio Awazu

2021 ◽  
Vol 187 (1) ◽  
pp. 145-153
Author(s):  
Conor R. Lanahan ◽  
Bridget N. Kelly ◽  
Michele A. Gadd ◽  
Michelle C. Specht ◽  
Carson L. Brown ◽  
...  

Abstract Purpose Safe breast cancer lumpectomies require microscopically clear margins. Real-time margin assessment options are limited, and 20–40% of lumpectomies have positive margins requiring re-excision. The LUM Imaging System previously showed excellent sensitivity and specificity for tumor detection during lumpectomy surgery. We explored its impact on surgical workflow and performance across patient and tumor types. Methods We performed IRB-approved, prospective, non-randomized studies in breast cancer lumpectomy procedures. The LUM Imaging System uses LUM015, a protease-activated fluorescent imaging agent that identifies residual tumor in the surgical cavity walls. Fluorescent cavity images were collected in real-time and analyzed using system software. Results Cavity and specimen images were obtained in 55 patients injected with LUM015 at 0.5 or 1.0 mg/kg and in 5 patients who did not receive LUM015. All tumor types were distinguished from normal tissue, with mean tumor:normal (T:N) signal ratios of 3.81–5.69. T:N ratios were 4.45 in non-dense and 4.00 in dense breasts (p = 0.59) and 3.52 in premenopausal and 4.59 in postmenopausal women (p = 0.19). Histopathology and tumor receptor testing were not affected by LUM015. Falsely positive readings were more likely when tumor was present < 2 mm from the adjacent specimen margin. LUM015 signal was stable in vivo at least 6.5 h post injection, and ex vivo at least 4 h post excision. Conclusions Intraoperative use of the LUM Imaging System detected all breast cancer subtypes with robust performance independent of menopausal status and breast density. There was no significant impact on histopathology or receptor evaluation.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 861
Author(s):  
Elizabeth E. Niedert ◽  
Chenghao Bi ◽  
Georges Adam ◽  
Elly Lambert ◽  
Luis Solorio ◽  
...  

A microrobot system comprising an untethered tumbling magnetic microrobot, a two-degree-of-freedom rotating permanent magnet, and an ultrasound imaging system has been developed for in vitro and in vivo biomedical applications. The microrobot tumbles end-over-end in a net forward motion due to applied magnetic torque from the rotating magnet. By turning the rotational axis of the magnet, two-dimensional directional control is possible and the microrobot was steered along various trajectories, including a circular path and P-shaped path. The microrobot is capable of moving over the unstructured terrain within a murine colon in in vitro, in situ, and in vivo conditions, as well as a porcine colon in ex vivo conditions. High-frequency ultrasound imaging allows for real-time determination of the microrobot’s position while it is optically occluded by animal tissue. When coated with a fluorescein payload, the microrobot was shown to release the majority of the payload over a 1-h time period in phosphate-buffered saline. Cytotoxicity tests demonstrated that the microrobot’s constituent materials, SU-8 and polydimethylsiloxane (PDMS), did not show a statistically significant difference in toxicity to murine fibroblasts from the negative control, even when the materials were doped with magnetic neodymium microparticles. The microrobot system’s capabilities make it promising for targeted drug delivery and other in vivo biomedical applications.


2005 ◽  
Vol 49 (1) ◽  
pp. 380-387 ◽  
Author(s):  
Yan Q. Xiong ◽  
Julie Willard ◽  
Jagath L. Kadurugamuwa ◽  
Jun Yu ◽  
Kevin P. Francis ◽  
...  

ABSTRACT Therapeutic options for invasive Staphylococcus aureus infections have become limited due to rising antimicrobial resistance, making relevant animal model testing of new candidate agents more crucial than ever. In the present studies, a rat model of aortic infective endocarditis (IE) caused by a bioluminescently engineered, biofilm-positive S. aureus strain was used to evaluate real-time antibiotic efficacy directly. This strain was vancomycin and cefazolin susceptible but gentamicin resistant. Bioluminescence was detected and quantified daily in antibiotic-treated and control animals with IE, using a highly sensitive in vivo imaging system (IVIS). Persistent and increasing cardiac bioluminescent signals (BLS) were observed in untreated animals. Three days of vancomycin therapy caused significant reductions in both cardiac BLS (>10-fold versus control) and S. aureus densities in cardiac vegetations (P < 0.005 versus control). However, 3 days after discontinuation of vancomycin therapy, a greater than threefold increase in cardiac BLS was observed, indicating relapsing IE (which was confirmed by quantitative culture). Cefazolin resulted in modest decreases in cardiac BLS and bacterial densities. These microbiologic and cardiac BLS differences during therapy correlated with a longer time-above-MIC for vancomycin (>12 h) than for cefazolin (∼4 h). Gentamicin caused neither a reduction in cardiac S. aureus densities nor a reduction in BLS. There were significant correlations between cardiac BLS and S. aureus densities in vegetations in all treatment groups. These data suggest that bioluminescent imaging provides a substantial advance in the real-time monitoring of the efficacy of therapy of invasive S. aureus infections in live animals.


2014 ◽  
Vol 19 (07) ◽  
pp. 1 ◽  
Author(s):  
Umar S. Alqasemi ◽  
Hai Li ◽  
Guangqian Yuan ◽  
Patrick D. Kumavor ◽  
Saeid Zanganeh ◽  
...  

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Jeesu Kim ◽  
Sara Park ◽  
Yuhan Jung ◽  
Sunyeob Chang ◽  
Jinyong Park ◽  
...  

Hypertension ◽  
2015 ◽  
Vol 66 (suppl_1) ◽  
Author(s):  
Teresa Krieger-Burke ◽  
Bridget M Seitz ◽  
Gregory D Fink ◽  
Stephanie W Watts

The purpose of our study was to investigate serial ultrasound imaging in rats as a means to quantify the diameters of splanchnic veins in real time and the effect of drugs on venous capacitance. A 21 MHz probe ( Vevo 2100 imaging system,Visual Sonics Inc.) was used to collect images containing the portal vein (PV) and the superior mesenteric vein (SMV) in anesthetized male Sprague-Dawley rats maintained at 37°C. Stable landmarks were established and we were able to repeatedly locate specific cross-sections of PV and SMV. When controlled for respiratory and cardiac cycles during measurements, respective diameters of these vessels remained within 0.75±0.15% and 0.2±0.10% of baseline (PV: 2.02±0.15 mm; SMV: 1.67±0.05 mm) when located and measured every 5 minutes over 45 minutes (n=3 rats). PV and SMV remained within 1.0±0.6% and 0.38±0.9% from baseline, respectively, when measured on separate days over 10 weeks in a preliminary study using 2 rats. The consistency of raw vessel measurements allowed these vessels to serve as their own control during subchronic pharmacologic interventions. In a second study, the vasodilator sodium nitroprusside (2 mg/kg, i.v. bolus) was administered to anesthetized rats (n=3) following collection of baseline vessel measurements. PV and SMV diameters increased 37.23±2.4% and 29.77±8.8% from baseline by 30 minutes post drug administration while mean arterial pressure decreased 10.32±1.7 mmHg. Conversely, the administration of the venoconstrictor sarafotoxin (S6C) (5 ng/kg, i.v. bolus) to other anesthetized rats (n=3) decreased PV and SMV diameters 22.10±2.4% and 9.44±1.6% from baseline within 5 minutes, associated with an increase in mean arterial pressure of 12.85±3.2 mmHg. Together these results support serial ultrasound imaging as a reliable technique to accurately measure acute and subchronic changes in the diameter of splanchnic veins concurrent with blood pressure changes in intact rats. The ability to follow rat abdominal vein diameters in real time will assist in determining the role of the venous circulation in blood pressure regulation.


Sign in / Sign up

Export Citation Format

Share Document