Heart segmentation from chest x-ray images based on improved active shape model

Author(s):  
RUI JIANG ◽  
XiaoLin Tian
MATICS ◽  
2015 ◽  
Vol 7 (1) ◽  
pp. 1
Author(s):  
Linda Salma

<p class="Text"><em>Abstrak</em> -Secara umum penentuan kontur maupun diameter jantung masih dilakukan secara manual, diamati dan di tentukan oleh radiolog. Hasilnya sangat di pengaruhi oleh kemampuan maupun pengalaman dari ahli radiologi, karena faktor subyektifitas dalam pemeriksaan jantung pada citra x-ray rongga dada oleh radiolog, maka diperlukan alternatif metode yang mampu memberikan analisis yang lebih baik (obyektif) dan dapat dipergunakan dalam berbagai hal. Pada penelitian ini menggunakan metode Active Shape Model untuk segmentasi Jantung dari hasil citra x-ray rongga dada. Segmentasi  jantung  pada  citra  x-ray  thorax  menggunakan  Active  Shape  Model dengan  landmark  5,  10  dan  15  diperoleh hasil  : akurasi 85.84% (untuk landmark 15 point), sensitifitas 77.38% (untuk landmark 15 point), dan spesifitas 91.39 % (untuk landmark 10 point) dengan tingkat akurasi tersebut menunjukkan bahwa metode ini dapat digunakan untuk segmentasi bagian jantung pada citra x-ray rongga dada.</p>


Author(s):  
Vinaya B ◽  
Akila C ◽  
Dinesh Babu J ◽  
Sravan Kumar P

This study aims to inaugurate the comparison among entire hip bone mineral density (RMD) by dual-energy X-ray absorptiometry (DEXA) and a humble clavicle radiogrammetry complete from the ribcage radiograph that provides the result of extraordinary sensitivity and specificity for forecasting full hip BMD from ribcage radiograph for assessment of osteoporosis. Clavicle Radiogrammetry is a method to measure morphometric dimensions like the other and inner diameter of the clavicle at its mid-shaft. Form these measurements; the following Bone Mass Indices are to be calculated, such as the cortical thickness and the Relative thickness. The Clavicle bone is separated from the digital chest X-ray. The Clavicle bone is identified and separated using Active Shape Model algorithm. After this, the morphometric measurements are done. The outcome of the study is whether the digitized chest X-ray analyzed is helpful in the evaluation of osteoporosis or not.


2009 ◽  
Vol 29 (10) ◽  
pp. 2710-2712 ◽  
Author(s):  
Li-qiang DU ◽  
Peng JIA ◽  
Zong-tan ZHOU ◽  
De-wen HU

2021 ◽  
Vol 69 ◽  
pp. 102807
Author(s):  
Yasser Ali ◽  
Soosan Beheshti ◽  
Farrokh Janabi-Sharifi

Sign in / Sign up

Export Citation Format

Share Document