Power distribution from insertion device x-ray sources

Author(s):  
P. J. Viccaro
2021 ◽  
Vol 5 (3) ◽  
pp. 80
Author(s):  
George Youssef ◽  
Scott Newacheck ◽  
Nha Uyen Huynh ◽  
Carlos Gamez

Fiber-reinforced polymer matrix composites continue to attract scientific and industrial interest since they offer superior strength-, stiffness-, and toughness-to-weight ratios. The research herein characterizes two sets of E-Glass/Epoxy composite skins: stressed and unstressed. The stressed samples were previously installed in an underground power distribution vault and were exposed to fire while the unstressed composite skins were newly fabricated and never-deployed samples. The mechanical, morphological, and elemental composition of the samples were methodically studied using a dynamic mechanical analyzer, a scanning electron microscope (SEM), and an x-ray diffractometer, respectively. Sandwich composite panels consisting of E-glass/Epoxy skin and balsa wood core were originally received, and the balsa wood was removed before any further investigations. Skin-only specimens with dimensions of ~12.5 mm wide, ~70 mm long, and ~6 mm thick were tested in a Dynamic Mechanical Analyzer in a dual-cantilever beam configuration at 5 Hz and 10 Hz from room temperature to 210 °C. Micrographic analysis using the SEM indicated a slight change in morphology due to the fire event but confirmed the effectiveness of the fire-retardant agents in quickly suppressing the fire. Accompanying Fourier transform infrared and energy dispersive X-ray spectroscopy studies corroborated the mechanical and morphological results. Finally, X-ray diffraction showed that the fire event consumed the surface level fire-retardant and the structural attributes of the E-Glass/Epoxy remained mainly intact. The results suggest the panels can continue field deployment, even after short fire incident.


2014 ◽  
Vol 21 (4) ◽  
pp. 815-818 ◽  
Author(s):  
A. Rack ◽  
M. Scheel ◽  
L. Hardy ◽  
C. Curfs ◽  
A. Bonnin ◽  
...  

First real-time studies of ultra-fast processes by single-bunch imaging at the European Synchrotron Radiation Facility are reported. By operating the storage ring of the ESRF in single-bunch mode with its correspondingly increased electron bunch charge density per singlet, the polychromatic photon flux density at insertion-device beamlines is sufficient to capture hard X-ray images exploiting the light from a single bunch (the corresponding bunch length is 140 ps FWHM). Hard X-ray imaging with absorption contrast as well as phase contrast in combination with large propagation distances is demonstrated using spatial samplings of 11 µm and 35 µm pixel size. The images acquired allow one to track crack propagation in a bursting piece of glass, breaking of an electrical fuse as well as cell wall rupture in an aqueous foam. Future developments and their potential in the frame of the proposed Phase II of the ESRF Upgrade Program are discussed.


2016 ◽  
Vol 23 (5) ◽  
pp. 1082-1086 ◽  
Author(s):  
Eric M. Dufresne ◽  
Robert W. Dunford ◽  
Elliot P. Kanter ◽  
Yuan Gao ◽  
Seoksu Moon ◽  
...  

The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm−2was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. A method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.


2019 ◽  
Vol 4 (1) ◽  
pp. 7 ◽  
Author(s):  
Antonella Balerna

X-ray Absorption Fine Structure Spectroscopy (XAFS) is a powerful technique to investigate the local atomic geometry and the chemical state of atoms in different types of materials, especially if lacking a long-range order, such as nanomaterials, liquids, amorphous and highly disordered systems, and polymers containing metallic atoms. The INFN-LNF DAΦNE-Light DXR1 beam line is mainly dedicated to soft X-ray absorption spectroscopy; it collects the radiation of a wiggler insertion device and covers the energy range from 0.9 to 3.0 keV or the range going from the K-edge of Na through to the K-edge of Cl. The characteristics of the beamline are reported here together with the XAFS spectra of reference compounds, in order to show some of the information achievable with this X-ray spectroscopy. Additionally, some examples of XAFS spectroscopy applications are also reported.


2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Julianne Nichols ◽  
Natalie Berger ◽  
Praveen Joseph ◽  
Debapriya Datta

Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT) of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.


2004 ◽  
Vol 37 (5) ◽  
pp. 836-840 ◽  
Author(s):  
R. W. Alkire ◽  
R. Schuessler ◽  
F. J. Rotella ◽  
J. D. Gonczy ◽  
G. Rosenbaum

A 1 mm vertical-profile X-ray beamstop has been designed to operate in the energy range 6–20 keV. The relationship between the beamstop-to-sample distance and air scatter is discussed with the intent of establishing criteria for optimal beamstop positioning during an experiment. Different choices for beamstop materials are described with respect to stopping power, fluorescence and scattering from the surface. Suggestions for improvements in beamstop design are presented which are applicable for future automation and equipment safety. All work was performed on the Structural Biology Center insertion-device beamline, 19ID, at the Advanced Photon Source.


Sign in / Sign up

Export Citation Format

Share Document