Sensitivity analysis for high-contrast imaging with segmented space telescopes

Author(s):  
Lucie Leboulleux ◽  
Laurent Pueyo ◽  
Jean-François Sauvage ◽  
Rémi Soummer ◽  
Thierry Fusco ◽  
...  
2020 ◽  
Vol 639 ◽  
pp. A70
Author(s):  
Lucie Leboulleux ◽  
Jean-François Sauvage ◽  
Rémi Soummer ◽  
Thierry Fusco ◽  
Laurent Pueyo ◽  
...  

Context. Direct imaging of Earth-like planets from space requires dedicated observatories, combining large segmented apertures with instruments and techniques such as coronagraphs, wavefront sensors, and wavefront control in order to reach the high contrast of 1010 that is required. The complexity of these systems would be increased by the segmentation of the primary mirror, which allows for the larger diameters necessary to image Earth-like planets but also introduces specific patterns in the image due to the pupil shape and segmentation and making high-contrast imaging more challenging. Among these defects, the phasing errors of the primary mirror are a strong limitation to the performance. Aims. In this paper, we focus on the wavefront sensing of segment phasing errors for a high-contrast system, using the COronagraphic Focal plane wave-Front Estimation for Exoplanet detection (COFFEE) technique. Methods. We implemented and tested COFFEE on the High-contrast imaging for Complex Aperture Telescopes (HiCAT) testbed, in a configuration without any coronagraph and with a classical Lyot coronagraph, to reconstruct errors applied on a 37 segment mirror. We analysed the quality and limitations of the reconstructions. Results. We demonstrate that COFFEE is able to estimate correctly the phasing errors of a segmented telescope for piston, tip, and tilt aberrations of typically 100 nm RMS. We also identified the limitations of COFFEE for the reconstruction of low-order wavefront modes, which are highly filtered by the coronagraph. This is illustrated using two focal plane mask sizes on HiCAT. We discuss possible solutions, both in the hardware system and in the COFFEE optimizer, to mitigate these issues.


Author(s):  
Uwe Lücken ◽  
Michael Felsmann ◽  
Wim M. Busing ◽  
Frank de Jong

A new microscope for the study of life science specimen has been developed. Special attention has been given to the problems of unstained samples, cryo-specimens and x-ray analysis at low concentrations.A new objective lens with a Cs of 6.2 mm and a focal length of 5.9 mm for high-contrast imaging has been developed. The contrast of a TWIN lens (f = 2.8 mm, Cs = 2 mm) and the BioTWTN are compared at the level of mean and SD of slow scan CCD images. Figure 1a shows 500 +/- 150 and Fig. 1b only 500 +/- 40 counts/pixel. The contrast-forming mechanism for amplitude contrast is dependent on the wavelength, the objective aperture and the focal length. For similar image conditions (same voltage, same objective aperture) the BioTWIN shows more than double the contrast of the TWIN lens. For phasecontrast specimens (like thin frozen-hydrated films) the contrast at Scherzer focus is approximately proportional to the √ Cs.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Shangfeng Wang ◽  
Yong Fan ◽  
Dandan Li ◽  
Caixia Sun ◽  
Zuhai Lei ◽  
...  

2004 ◽  
Author(s):  
Alessandro Berton ◽  
Raffaele G. Gratton ◽  
Markus Feldt ◽  
Silvano Desidera ◽  
Elena Masciadri ◽  
...  

2012 ◽  
Author(s):  
Jiangpei Dou ◽  
Deqing Ren ◽  
Yongtian Zhu ◽  
Xi Zhang ◽  
Rong Li

2015 ◽  
Author(s):  
Aaron J. Lemmer ◽  
Tyler D. Groff ◽  
N. Jeremy Kasdin ◽  
Daniel Echeverri ◽  
Isabel R. Cleff

Author(s):  
Eduardo Bendek ◽  
Ruslan Belikov ◽  
Dan Sirbu ◽  
Garreth Ruane ◽  
A. J. Eldorado Riggs ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document