Raman spectroscopy reveals biophysical markers in skin cancer surgical margins

Author(s):  
Xu Feng ◽  
Austin J. Moy ◽  
Hieu T. M. Nguyen ◽  
Yao Zhang ◽  
Matthew C. Fox ◽  
...  
Author(s):  
M.N. Calienni ◽  
J. Montanari ◽  
M.E. Tuttolomondo ◽  
G. Gomez ◽  
V. Alonso S. del ◽  
...  

2013 ◽  
Author(s):  
Fabrício Luiz Silveira ◽  
Marcos Tadeu T. Pacheco ◽  
Benito Bodanese ◽  
Renato Amaro Zângaro ◽  
Landulfo Silveira

2016 ◽  
Vol 21 (1) ◽  
pp. 40-41 ◽  
Author(s):  
Rob Bobotsis ◽  
Lyn Guenther

Mohs surgery is considered ideal treatment for many types of skin cancers. Developed by Dr Frederic Edward Mohs (1910-2002), Mohs surgery allows all surgical margins to be viewed microscopically, ensuring no cancer cells go unremoved, yet it failed to achieve immediate acceptance when first introduced in the 1940s. A catalyst to the widespread acceptance of Mohs surgery occurred with the work of dermatologic colleagues who reported excellent results without using the paste. It suggested the real innovation of Mohs surgery lay in its microscopic control and not the paste, the discontinuation of which removed all the problems associated with its use.


2021 ◽  
Vol 11 (20) ◽  
pp. 9498
Author(s):  
Martha Z. Vardaki ◽  
Konstantinos Seretis ◽  
Georgios Gaitanis ◽  
Ioannis D. Bassukas ◽  
Nikolaos Kourkoumelis

Skin cancer is currently the most common type of cancer with millions of cases diagnosed worldwide yearly. The current gold standard for clinical diagnosis of skin cancer is an invasive and relatively time-consuming procedure, consisting of visual examination followed by biopsy collection and histopathological analysis. Raman spectroscopy has been shown to efficiently aid the non-invasive diagnosis of skin cancer when probing the surface of the skin. In this study, we employ a recent development of Raman spectroscopy (Spatially Offset Raman Spectroscopy, SORS) which is able to look deeper in tissue and create a deep layer biochemical profile of the skin in areas where cancer lesions subtly evolve. After optimizing the measurement parameters on skin tissue phantoms, we then adopted SORS on human skin tissue from different anatomical areas to investigate the contribution of the different skin layers to the recorded Raman signal. Our results show that using a diffuse beam with zero offset to probe a sampling volume where the lesion is typically included (surface to epidermis-dermis junction), provides the optimum signal-to-noise ratio (SNR) and may be employed in future skin cancer screening applications.


Sign in / Sign up

Export Citation Format

Share Document