Thomson scattering x-ray source: a novel tool for monochromatic computed tomography

Author(s):  
Yingchao Du ◽  
Zhijun Chi ◽  
Chuanxiang Tang ◽  
Wenhui Huang ◽  
Lixin Yan ◽  
...  
2020 ◽  
Vol 27 (3) ◽  
pp. 737-745
Author(s):  
Zhijun Chi ◽  
Yingchao Du ◽  
Wenhui Huang ◽  
Chuanxiang Tang

A Thomson scattering X-ray source can provide quasi-monochromatic, continuously energy-tunable, polarization-controllable and high-brightness X-rays, which makes it an excellent tool for X-ray fluorescence computed tomography (XFCT). In this paper, we examined the suppression of Compton scattering background in XFCT using the linearly polarized X-rays and the implementation feasibility of linearly polarized XFCT based on this type of light source, concerning the influence of phantom attenuation and the sampling strategy, its advantage over K-edge subtraction computed tomography (CT), the imaging time, and the potential pulse pile-up effect by Monte Carlo simulations. A fan beam and pinhole collimator geometry were adopted in the simulation and the phantom was a polymethyl methacrylate cylinder inside which were gadolinium (Gd)-loaded water solutions with Gd concentrations ranging from 0.2 to 4.0 wt%. Compared with the case of vertical polarization, Compton scattering was suppressed by about 1.6 times using horizontal polarization. An accurate image of the Gd-containing phantom was successfully reconstructed with both spatial and quantitative identification, and good linearity between the reconstructed value and the Gd concentration was verified. When the attenuation effect cannot be neglected, one full cycle (360°) sampling and the attenuation correction became necessary. Compared with the results of K-edge subtraction CT, the contrast-to-noise ratio values of XFCT were improved by 2.03 and 1.04 times at low Gd concentrations of 0.2 and 0.5 wt%, respectively. When the flux of a Thomson scattering light source reaches 1013 photons s−1, it is possible to finish the data acquisition of XFCT at the minute or second level without introducing pulse pile-up effects.


2018 ◽  
Vol 25 (6) ◽  
pp. 1797-1802 ◽  
Author(s):  
Zhijun Chi ◽  
Yingchao Du ◽  
Lixin Yan ◽  
Dong Wang ◽  
Hongze Zhang ◽  
...  

Unlike large-scale and expensive synchrotron radiation facilities, the Thomson scattering X-ray source can provide quasi-monochromatic, energy-tunable and high-brightness X-ray pulses with a small footprint and moderate cost, making it an excellent candidate for dual-energy and multi-energy imaging at laboratories and hospitals. Here, the first feasibility study on dual-energy computed tomography (CT) based on this type of light source is reported, and the effective atomic number and electron-density distribution of a standard phantom consisting of polytetrafluoroethylene, water and aluminium is derived. The experiment was carried out at the Tsinghua Thomson scattering X-ray source with peak energies of 29 keV and 68 keV. Both the reconstructed effective atomic numbers and the retrieved electron densities of the three materials were compared with their theoretical values. It was found that these values were in agreement by 0.68% and 2.60% on average for effective atomic number and electron density, respectively. These results have verified the feasibility of dual-energy CT based on the Thomson scattering X-ray source and will further expand the scope of X-ray imaging using this type of light source.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


1999 ◽  
Vol 11 (1) ◽  
pp. 199-211
Author(s):  
J. M. Winter ◽  
R. E. Green ◽  
A. M. Waters ◽  
W. H. Green

2020 ◽  
Vol 45 (3) ◽  
pp. 478-482
Author(s):  
Steven R. Manchester

Abstract—The type material on which the fossil genus name Ampelocissites was established in 1929 has been reexamined with the aid of X-ray micro-computed tomography (μ-CT) scanning and compared with seeds of extant taxa to assess the relationships of these fossils within the grape family, Vitaceae. The specimens were collected from a sandstone of late Paleocene or early Eocene age. Although originally inferred by Berry to be intermediate in morphology between Ampelocissus and Vitis, the newly revealed details of seed morphology indicate that these seeds represent instead the Ampelopsis clade. Digital cross sections show that the seed coat maintains its thickness over the external surfaces, but diminishes quickly in the ventral infolds. This feature, along with the elliptical chalaza and lack of an apical groove, indicate that Ampelocissites lytlensis Berry probably represents Ampelopsis or Nekemias (rather than Ampelocissus or Vitis) and that the generic name Ampelocissites may be useful for fossil seeds with morphology consistent with the Ampelopsis clade that lack sufficient characters to specify placement within one of these extant genera.


2020 ◽  
Vol 3 ◽  
pp. 36-39
Author(s):  
Samson O. Paulinus ◽  
Benjamin E. Udoh ◽  
Bassey E. Archibong ◽  
Akpama E. Egong ◽  
Akwa E. Erim ◽  
...  

Objective: Physicians who often request for computed tomography (CT) scan examinations are expected to have sound knowledge of radiation exposure (risks) to patients in line with the basic radiation protection principles according to the International Commission on Radiological Protection (ICRP), the Protection of Persons Undergoing Medical Exposure or Treatment (POPUMET), and the Ionizing Radiation (Medical Exposure) Regulations (IR(ME)R). The aim is to assess the level of requesting physicians’ knowledge of ionizing radiation from CT scan examinations in two Nigerian tertiary hospitals. Materials and Methods: An 18-item-based questionnaire was distributed to 141 practicing medical doctors, excluding radiologists with work experience from 0 to >16 years in two major teaching hospitals in Nigeria with a return rate of 69%, using a voluntary sampling technique. Results: The results showed that 25% of the respondents identified CT thorax, abdomen, and pelvis examination as having the highest radiation risk, while 22% said that it was a conventional chest X-ray. Furthermore, 14% concluded that CT head had the highest risk while 9% gave their answer to be conventional abdominal X-ray. In addition, 17% inferred that magnetic resonance imaging had the highest radiation risk while 11% had no idea. Furthermore, 25.5% of the respondents have had training on ionizing radiation from CT scan examinations while 74.5% had no training. Majority (90%) of the respondents were not aware of the ICRP guidelines for requesting investigations with very little (<3%) or no knowledge (0%) on the POPUMET and the IR(ME)R respectively. Conclusion: There is low level of knowledge of ionizing radiation from CT scan examinations among requesting physicians in the study locations.


Sign in / Sign up

Export Citation Format

Share Document