Weighted singular value decomposition (wSVD) to improve the radiation dose efficiency of grating-based x-ray phase contrast imaging with a photon counting detector

2017 ◽  
Author(s):  
Xu Ji ◽  
Yongshuai Ge ◽  
Ran Zhang ◽  
Ke Li ◽  
Guang-Hong Chen
2016 ◽  
Author(s):  
S. Sano ◽  
K. Tanabe ◽  
T. Yoshimuta ◽  
K. Kimura ◽  
T. Shirai ◽  
...  

2022 ◽  
Vol 17 (01) ◽  
pp. C01043
Author(s):  
L. Brombal ◽  
L. Rigon ◽  
F. Arfelli ◽  
R.H. Menk ◽  
F. Brun

Abstract The PEPI project is developing a new experimental facility integrating a chromatic photon-counting detector within an edge-illumination (EI) phase-contrast setup. In this context, a novel Geant4-based simulation tool has been introduced with the aim of defining the optimal design of the experimental setup. The code includes a custom X-ray refraction process and allows simulating the whole EI system, comprising a polychromatic and extended source, absorbing masks, substrates, their movement during acquisition, and X-ray detection. In this paper, a realistic spectral detector model is introduced and its energy response validated against experimental data acquired with synchrotron radiation at energies between 26 and 50 keV. Moreover, refraction and transmission images of a plastic phantom are reconstructed from simulation data and successfully compared with theoretical predictions. Finally, an optimization study aiming at finding the effect of the X-ray focal spot size (i.e. spatial coherence) on image quality is presented; the results suggest that, in the considered configuration, the system can tolerate source sizes up to 30 μm, while, for a fixed exposure time, the best signal-to-noise ratio in refraction images is found for source sizes in the order of 10 to 15 μm.


2013 ◽  
Vol 21 (22) ◽  
pp. 25677 ◽  
Author(s):  
Georg Pelzer ◽  
Thomas Weber ◽  
Gisela Anton ◽  
Rafael Ballabriga ◽  
Florian Bayer ◽  
...  

2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Sign in / Sign up

Export Citation Format

Share Document