Limits on imaging resolution of focused ion-beam systems

Author(s):  
Jon Orloff
2021 ◽  
Vol 40 (9) ◽  
pp. 662-666
Author(s):  
Mita Sengupta ◽  
Shannon L. Eichmann

Digital rocks are 3D image-based representations of pore-scale geometries that reside in virtual laboratories. High-resolution 3D images that capture microstructural details of the real rock are used to build a digital rock. The digital rock, which is a data-driven model, is used to simulate physical processes such as fluid flow, heat flow, electricity, and elastic deformation through basic laws of physics and numerical simulations. Unconventional reservoirs are chemically heterogeneous where the rock matrix is composed of inorganic minerals, and hydrocarbons are held in the pores of thermally matured organic matter, all of which vary spatially at the nanoscale. This nanoscale heterogeneity poses challenges in measuring the petrophysical properties of source rocks and interpreting the data with reference to the changing rock structure. Focused ion beam scanning electron microscopy is a powerful 3D imaging technique used to study source rock structure where significant micro- and nanoscale heterogeneity exists. Compared to conventional rocks, the imaging resolution required to image source rocks is much higher due to the nanoscale pores, while the field of view becomes smaller. Moreover, pore connectivity and resulting permeability are extremely low, making flow property computations much more challenging than in conventional rocks. Elastic properties of source rocks are significantly more anisotropic than those of conventional reservoirs. However, one advantage of unconventional rocks is that the soft organic matter can be captured at the same imaging resolution as the stiff inorganic matrix, making digital elasticity computations feasible. Physical measurement of kerogen elastic properties is difficult because of the tiny sample size. Digital rock physics provides a unique and powerful tool in the elastic characterization of kerogen.


2002 ◽  
Vol 733 ◽  
Author(s):  
Brock McCabe ◽  
Steven Nutt ◽  
Brent Viers ◽  
Tim Haddad

AbstractPolyhedral Oligomeric Silsequioxane molecules have been incorporated into a commercial polyurethane formulation to produce nanocomposite polyurethane foam. This tiny POSS silica molecule has been used successfully to enhance the performance of polymer systems using co-polymerization and blend strategies. In our investigation, we chose a high-temperature MDI Polyurethane resin foam currently used in military development projects. For the nanofiller, or “blend”, Cp7T7(OH)3 POSS was chosen. Structural characterization was accomplished by TEM and SEM to determine POSS dispersion and cell morphology, respectively. Thermal behavior was investigated by TGA. Two methods of TEM sample preparation were employed, Focused Ion Beam and Ultramicrotomy (room temperature).


2002 ◽  
Vol 719 ◽  
Author(s):  
Myoung-Woon Moon ◽  
Kyang-Ryel Lee ◽  
Jin-Won Chung ◽  
Kyu Hwan Oh

AbstractThe role of imperfections on the initiation and propagation of interface delaminations in compressed thin films has been analyzed using experiments with diamond-like carbon (DLC) films deposited onto glass substrates. The surface topologies and interface separations have been characterized by using the Atomic Force Microscope (AFM) and the Focused Ion Beam (FIB) imaging system. The lengths and amplitudes of numerous imperfections have been measured by AFM and the interface separations characterized on cross sections made with the FIB. Chemical analysis of several sites, performed using Auger Electron Spectroscopy (AES), has revealed the origin of the imperfections. The incidence of buckles has been correlated with the imperfection length.


2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


2018 ◽  
Author(s):  
Sang Hoon Lee ◽  
Jeff Blackwood ◽  
Stacey Stone ◽  
Michael Schmidt ◽  
Mark Williamson ◽  
...  

Abstract The cross-sectional and planar analysis of current generation 3D device structures can be analyzed using a single Focused Ion Beam (FIB) mill. This is achieved using a diagonal milling technique that exposes a multilayer planar surface as well as the cross-section. this provides image data allowing for an efficient method to monitor the fabrication process and find device design errors. This process saves tremendous sample-to-data time, decreasing it from days to hours while still providing precise defect and structure data.


2018 ◽  
Author(s):  
Steve Wang ◽  
Jim McGinn ◽  
Peter Tvarozek ◽  
Amir Weiss

Abstract Secondary electron detector (SED) plays a vital role in a focused ion beam (FIB) system. A successful circuit edit requires a good effective detector. Novel approach is presented in this paper to improve the performance of such a detector, making circuit altering for the most advanced integrated circuit (IC) possible.


Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


Author(s):  
Valery Ray

Abstract Gas Assisted Etching (GAE) is the enabling technology for High Aspect Ratio (HAR) circuit access via milling in Focused Ion Beam (FIB) circuit modification. Metal interconnect layers of microelectronic Integrated Circuits (ICs) are separated by Inter-Layer Dielectric (ILD) materials, therefore HAR vias are typically milled in dielectrics. Most of the etching precursor gases presently available for GAE of dielectrics on commercial FIB systems, such as XeF2, Cl2, etc., are also effective etch enhancers for either Si, or/and some of the metals used in ICs. Therefore use of these precursors for via milling in dielectrics may lead to unwanted side effects, especially in a backside circuit edit approach. Making contacts to the polysilicon lines with traditional GAE precursors could also be difficult, if not impossible. Some of these precursors have a tendency to produce isotropic vias, especially in Si. It has been proposed in the past to use fluorocarbon gases as precursors for the FIB milling of dielectrics. Preliminary experimental evaluation of Trifluoroacetic (Perfluoroacetic) Acid (TFA, CF3COOH) as a possible etching precursor for the HAR via milling in the application to FIB modification of ICs demonstrated that highly enhanced anisotropic milling of SiO2 in HAR vias is possible. A via with 9:1 aspect ratio was milled with accurate endpoint on Si and without apparent damage to the underlying Si substrate.


Sign in / Sign up

Export Citation Format

Share Document