Reduction in the amount of crosstalk with reduced number of focal spot rows in a grating array based zonal wavefront sensor

2015 ◽  
Author(s):  
Biswajit Pathak ◽  
Bosanta R. Boruah
2010 ◽  
Vol 09 (03) ◽  
pp. 123-133
Author(s):  
XIAOMING YIN ◽  
LIPING ZHAO ◽  
XIANG LI ◽  
ZHONGPING FANG

Shack–Hartmann wavefront sensor splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. The accuracy of the centroid measurement determines the accuracy of the SHWS. In this paper, we have presented an automatic centroid measurement method based on the image processing technology for practical applications of the digital SHWS in surface profile measurement. The method can detect the centroid of each focal spot accurately and robustly by eliminating the influences of various noises. Based on this centroid detection method, we have developed a digital SHWS system which can automatically detect centroids of focal spots, reconstruct the wavefront, and measure the 3D profile of the surface. The experimental results demonstrate that the system has good accuracy, repeatability and compatibility to optical misalignment. The system is suitable for online applications of surface measurement.


2005 ◽  
Author(s):  
Haiying Wang ◽  
Haifeng Duan ◽  
Changtao Wang ◽  
Yudong Zhang

Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2020 ◽  
Vol 78 (4) ◽  
pp. 479-486
Author(s):  
Marcela Tatiana Fernandes Beserra ◽  
◽  
Ricardo Tadeu Lopes ◽  
Davi Ferreira de Oliveira ◽  
Claudio Carvalho Conti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document