scholarly journals One-micron resolution optical coherence tomography (OCT) in vivo for cellular level imaging

2015 ◽  
Author(s):  
Dongyao Cui ◽  
Xinyu Liu ◽  
Jing Zhang ◽  
Xiaojun Yu ◽  
Ding Sun ◽  
...  
Author(s):  
Chien-Chung Tsai ◽  
Chia-Kai Chang ◽  
Kuang-Yu Hsu ◽  
Tuan-Shu Ho ◽  
Yu-Ta Wang ◽  
...  

Author(s):  
Viacheslav Mazlin ◽  
Eugénie Dalimier ◽  
Kate Grieve ◽  
Kristina Irsch ◽  
José Sahel ◽  
...  

Neurosurgery ◽  
2017 ◽  
Vol 64 (CN_suppl_1) ◽  
pp. 264-264 ◽  
Author(s):  
Derek W Yecies ◽  
Orly Liba ◽  
Elliot SoRelle ◽  
Rebecca Dutta ◽  
Christy Wilson ◽  
...  

Abstract INTRODUCTION Optical coherence tomography (OCT) is an emerging technology with the potential to allow for rapid intraoperative detection of brain tumor margins by detecting differences in structure, intensity, spectral signal, and attenuation. OCT systems are capable of rapid imaging of large three-dimensional volumes with cellular level resolution. However, OCT imaging has previously been limited by speckle artifact and the lack of suitable contrast agents, limitations that are surmounted in this study. METHODS We prepared nude mice with orthotopic U87 glioblastoma xenografts and glass cranial windows. We also created large gold nanorods (LGNR) with plasmonic peaks tuned to the spectral range of the OCT scanner. LGNRs were injected intravenously into tumor-bearing mice and OCT imaging was performed in vivo utilizing a novel method for the removal of speckle artifact called Speckle-Free OCT (SFOCT). Fresh ex-vivo patient samples were also imaged. RESULTS >OCT and SFOCT readily distinguished tumor from normal brain with cellular level spatial resolution and to a depth of 1.5 mm. Additionally, SFOCT allowed for the highest resolution ever seen in vivo of mouse white matter architecture. Cortical layers were also readily visible in SFOCT in both live mice and in the ex-vivo human samples, representing a novel ability to interrogate cortical cytoarchitecture across a large field of view. Systemically administered LGNRs were tumor specific and provided excellent spectral contrast using OCT. Ex-vivo hyperspectral and IHC imaging confirmed the localization of LGNRs within the tumor and found that the LGNRs were largely localized within tumor associated macrophages. CONCLUSION SFOCT and LGNR enhanced OCT imaging are promising state of the art technologies for intraoperative tumor margin detection.


2004 ◽  
Vol 171 (4S) ◽  
pp. 68-68 ◽  
Author(s):  
Markus D. Sachs ◽  
Dmitry Daniltchenko ◽  
Eva Lankenau ◽  
Frank Koenig ◽  
Gerion Huettmann ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 808
Author(s):  
Max Philipp Brinkmann ◽  
Nikolas Xavier Kibele ◽  
Michelle Prasuhn ◽  
Vinodh Kakkassery ◽  
Mario Damiano Toro ◽  
...  

Optical coherence tomography angiography (OCTA) is a non-invasive tool for imaging and quantifying the retinal and choroidal perfusion state in vivo. This study aimed to evaluate the acute effects of isometric and dynamic exercise on retinal and choroidal sublayer perfusion using OCTA. A pilot study was conducted on young, healthy participants, each of whom performed a specific isometric exercise on the first day and a dynamic exercise the day after. At baseline and immediately after the exercise, heart rate (HR), mean arterial pressure (MAP), superficial capillary plexus perfusion (SCPP), deep capillary plexus perfusion (DCPP), choriocapillaris perfusion (CCP), Sattlers’s layer perfusion (SLP), and Haller’s layer perfusion (HLP) were recorded. A total of 34 eyes of 34 subjects with a mean age of 32.35 ± 7.87 years were included. HR as well as MAP increased significantly after both types of exercise. Both SCPP and DCPP did not show any significant alteration due to isometric or dynamic exercise. After performing dynamic exercise, CCP, SLP, as well as HLP significantly increased. Changes in MAP correlated significantly with changes in HLP after the dynamic activity. OCTA-based analysis in healthy adults following physical activity demonstrated a constant retinal perfusion, supporting the theory of autoregulatory mechanisms. Dynamic exercise, as opposed to isometric activity, significantly changed choroidal perfusion. OCTA imaging may represent a novel and sensitive tool to expand the diagnostic spectrum in the field of sports medicine.


2017 ◽  
Vol 51 (4) ◽  
pp. 410-418 ◽  
Author(s):  
Rupert S. Austin ◽  
Maisalamah Haji Taha ◽  
Frederic Festy ◽  
Richard Cook ◽  
Manoharan Andiappan ◽  
...  

Swept-source optical coherence tomography (SS-OCT) shows potential for the in vivo quantitative evaluation of micro-structural enamel surface phenomena occurring during early erosive demineralization. This randomized controlled single-blind cross-over clinical study aimed to evaluate the use of SS-OCT for detecting optical changes in the enamel of 30 healthy volunteers subjected to orange juice rinsing (erosive challenge) in comparison to mineral water rinsing (control), according to wiped and non-wiped enamel surface states. Participants were randomly allocated to 60 min of orange juice rinsing (pH 3.8) followed by 60 min of water rinsing (pH 6.7) and vice versa, with a 2-week wash-out period. In addition, the labial surfaces of the right or left maxillary incisors were wiped prior to SS-OCT imaging. An automated ImageJ algorithm was designed to analyse the back-scattered OCT signal intensity (D) after orange juice rinsing compared to after water rinsing. D was quantified as the OCT signal scattering from the 33 µm sub-surface enamel, normalised by the total OCT signal intensity entering the enamel. The back-scattered OCT signal intensity increased by 3.1% (95% CI 1.1-5.1%) in the wiped incisors and by 3.5% (95% CI 1.5-5.5%) in the unwiped incisors (p < 0.0001). Wiping reduced the back-scattered OCT signal intensity by 1.7% (95% CI -3.2 to -0.3%; p = 0.02) in comparison to the unwiped enamel surfaces for both rinsing solutions (p = 0.2). SS-OCT detected OCT signal changes in the superficial sub-surface enamel of maxillary central incisor teeth of healthy volunteers after orange juice rinsing.


1998 ◽  
Vol 4 (7) ◽  
pp. 861-865 ◽  
Author(s):  
Stephan A. Boppart ◽  
Brett E. Bouma ◽  
Costas Pitris ◽  
James F. Southern ◽  
Mark E. Brezinski ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


Sign in / Sign up

Export Citation Format

Share Document