A calibration approach for terahertz wave measurements at frequencies from 0.11 THz to 0.17 THz

2013 ◽  
Author(s):  
Xue-feng Wang ◽  
Jian-guo Wang ◽  
Guang-qiang Wang ◽  
Chang-jiang Tong ◽  
Shuang Li
2020 ◽  
Vol 2020 (1) ◽  
pp. 100-104
Author(s):  
Hakki Can Karaimer ◽  
Rang Nguyen

Colorimetric calibration computes the necessary color space transformation to map a camera's device-specific color space to a device-independent perceptual color space. Color calibration is most commonly performed by imaging a color rendition chart with a fixed number of color patches with known colorimetric values (e. g., CIE XYZ values). The color space transformation is estimated based on the correspondences between the camera's image and the chart's colors. We present a new approach to colorimetric calibration that does not require explicit color correspondences. Our approach computes a color space transformation by aligning the color distributions of the captured image to the known distribution of a calibration chart containing thousands of colors. We show that a histogram-based colorimetric calibration approach provides results that are onpar with the traditional patch-based method without the need to establish correspondences.


1983 ◽  
Vol 18 (1) ◽  
pp. 129-150 ◽  
Author(s):  
Mark K. Watson ◽  
R.R. Hudgins ◽  
P.L. Silveston

Abstract Internal wave motion was studied in a laboratory rectangular, primary clarifier. A photo-extinction device was used as a turbidimeter to measure concentration fluctuations in a small volume within the clarifier as a function of time. The signal from this device was fed to a HP21MX minicomputer and the power spectrum plotted from data records lasting approximately 30 min. Results show large changes of wave amplitude as frequency increases. Two distinct regions occur: one with high amplitudes at frequencies below 0.03 Hz, the second with very small amplitudes appears for frequencies greater than 0.1 Hz. The former is associated with internal waves, the latter with flow-generated turbulence. Depth, velocity in the clarifier and inlet suspended solids influence wave amplitudes and the spectra. A variation with position or orientation of the probe was not detected. Contradictory results were found for the influence of flow contraction baffles on internal wave amplitude.


2013 ◽  
pp. 857-860
Author(s):  
F.L. Scarf ◽  
F.V. Coroniti ◽  
C.F. Kennel ◽  
T.R. Sanderson ◽  
K-P Wenzel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document