System parameters germane to relativistic klystron amplifiers: how the utility of pulse energy depends on pulse duration, the target, and the atmosphere

1994 ◽  
Author(s):  
John M. Myers
Materials ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1423 ◽  
Author(s):  
Dongkyoung Lee

An inspection process using a Spring Contact Probe (SCP) is an essential step in the semiconductor-manufacturing process. Many plungers, which are the main body of the SCP, are manufactured by a stamping process. After the stamping process, mechanical cutting is applied and the plunger body may be damaged. Thus, to improve cut quality and productivity while minimizing body damage, laser spot cutting can be used. To fully utilize this technology, it is necessary to investigate interaction characteristics of beryllium copper (BeCu) during laser spot cutting. Effects of a total irradiated laser-pulse energy (1 mJ ~1000 mJ ) and pulse duration (100 ns ~8 ns ) on the material-removal zone, thermal depth, and crater size are examined. The crater size can be affected by the localization of heating dominantly. An incubation model is applied to investigate the correlation between crater size and laser-pulse energy. Surface morphology characteristics such as edge separation, small particles, spatter motion, and soaring-up motion are observed.


2020 ◽  
Vol 203 ◽  
pp. e32
Author(s):  
Brandon Levin* ◽  
Ali Aldoukhi ◽  
Kristian Black ◽  
Timothy Hall ◽  
William Roberts ◽  
...  

2013 ◽  
Vol 302 ◽  
pp. 82-85 ◽  
Author(s):  
E.V. Berezneeva ◽  
N.S. Pushilina ◽  
D.V. Berezneev ◽  
I.P. Chernov ◽  
A.M. Lider ◽  
...  

Experimental results on the impact of pulsed ion beam with parameters the pulse duration 80 ns, energy of 200 keV and current density 120 А/сm2 , pulse energy ~ 1,5 J/сm2 on the alloy Zr1Nb on structure – phase state of the alloy of zirconium Zr1Nb. It is shown that such irradiation leads to changes in the structure of the surface and the hardening of the material.


2021 ◽  
Vol 127 (9) ◽  
Author(s):  
X. Li ◽  
L. Inhester ◽  
S. J. Robatjazi ◽  
B. Erk ◽  
R. Boll ◽  
...  
Keyword(s):  

2020 ◽  
Vol 8 ◽  
Author(s):  
Meng Wang ◽  
Yijian Huang ◽  
Zongpeng Song ◽  
Jincheng Wei ◽  
Jihong Pei ◽  
...  

We report on mode-locked thulium-doped fiber lasers with high-energy nanosecond pulses, relying on the transmission in a semiconductor saturable absorber (SESA) and a carbon nanotube (CNTs-PVA) film separately. A section of an SMF–MMF–SMF structure multimode interferometer with a transmission peak wavelength of ∼2003 nm was used as a wavelength selector to fix the laser wavelength. When the SESA acted as a saturable absorber (SA), the mode-locked fiber laser had a maximum output power of ∼461 mW with a pulse energy of ∼0.14 μJ and a pulse duration of ∼9.14 ns. In a CNT-film-based mode-locked fiber laser, stable mode-locked pulses with the maximum output power of ∼46 mW, pulse energy of ∼26.8 nJ and pulse duration of ∼9.3 ns were obtained. To the best of our knowledge, our experiments demonstrated the first 2 μm region ‘real’ SA-based dissipative soliton resonance with the highest mode-locked pulse energy from a ‘real’ SA-based all-fiberized resonator.


Author(s):  
Shoaib Sarfraz ◽  
Essam Shehab ◽  
Konstantinos Salonitis ◽  
Wojciech Suder ◽  
Misbah Niamat ◽  
...  

Laser drilling is a well-established manufacturing process utilised to produce holes in various aeroengine components. This research presents an experimental investigation on the effects of laser drilling process parameters on productivity (material removal rate), hole quality (hole taper) and drilling cost. Single-pulse drilling was employed to drill a thin-walled Inconel 718 superalloy plate of 1 mm thickness using pulsed Nd:YAG laser. The experiments were designed using Box-Behnken statistical approach to investigate the impacts of pulse energy, pulse duration, gas pressure and gas flow rate on the selected responses. Multi-objective optimisation was performed using response surface methodology (RSM) based grey rational analysis (GRA) to identify optimal drilling conditions aiming to maximise the MRR and minimise hole taper and drilling cost. The optimal combination of drilling parameters was found as pulse energy of 20 J, pulse duration of 6 ms, gas pressure of 100 psi and gas flow rate of 40 mm3/s. A detailed cost analysis identified labour cost, gas consumption and machine costs as the major cost elements of the laser drilling process.


1995 ◽  
Author(s):  
J. J. L. Horikx ◽  
Kiyoshi Osato ◽  
Naoya Eguchi ◽  
J. L. Bakx

2015 ◽  
Vol 234 (4) ◽  
pp. 177-188 ◽  
Author(s):  
Carsten Framme ◽  
Andreas Walter ◽  
Lieselotte Berger ◽  
Philipp Prahs ◽  
Clemens Alt ◽  
...  

Purpose: Selective retina therapy (SRT), the confined laser heating and destruction of retinal pigment epithelial cells, has been shown to treat acute types of central serous chorioretinopathy (CSC) successfully without damaging the photoreceptors and thus avoiding laser-induced scotoma. However, a benefit of laser treatment for chronic forms of CSC is questionable. In this study, the efficacy of SRT by means of the previously used 1.7-µs and shorter 300-ns pulse duration was evaluated for both types of CSC, also considering re-treatment for nonresponders. Material and Methods: In a two-center trial, 26 patients were treated with SRT for acute (n = 10) and chronic-recurrent CSC (n = 16). All patients presented with subretinal fluid (SRF) in OCT and leakage in fluorescein angiography (FA). SRT was performed using a prototype SRT laser system (frequency-doubled Q-switched Nd:YLF-laser, wavelength 527 nm) with adjustable pulse duration. The following irradiation settings were used: a train of 30 laser pulses with a repetition rate of 100 Hz and pulse durations of 300 ns and 1.7 µs, pulse energy 120-200 µJ, retinal spot size 200 µm. Because SRT lesions are invisible, FA was always performed 1 h after treatment to demonstrate laser outcome (5-8 single spots in the area of leakage). In cases where energy was too low, as indicated by missing FA leakage, energy was adjusted and the patient re-treated immediately. Observation intervals were after 4 weeks and 3 months. In case of nonimprovement of the disease after 3 months, re-treatment was considered. Results: Of 10 patients with active CSC that presents focal leakage in FA, 5 had completely resolved fluid after 4 weeks and all 10 after 3 months. Mean visual acuity increased from 76.6 ETDRS letters to 85.0 ETDRS letters 3 months after SRT. Chronic-recurrent CSC was characterized by less severe SRF at baseline in OCT and weaker leakage in FA than in acute types. Visual acuity changed from baseline 71.6 to 72.8 ETDRS letters after 3 months. At this time, SRF was absent in 3 out of 16 patients (19%), FA leakage had come to a complete stop in 6 out of 16 patients (38%). In 6 of the remaining chronic CSC patients, repeated SRT with higher pulse energy was considered because of persistent leakage activity. After the re-treatment, SRF resolved completely in 5 patients (83.3%) after only 25 days. Conclusion: SRT showed promising results in treating acute CSC, but was less effective in chronic cases. Interestingly, re-treatment resulted in enhanced fluid resolution and dry conditions after a considerably shorter time in most patients. Therefore, SRT including re-treatment if necessary might be a valuable CSC treatment alternative even in chronic-recurrent cases.


Sign in / Sign up

Export Citation Format

Share Document