Two-color in vivo dynamic contrast-enhanced pharmacokinetic imaging

2007 ◽  
Vol 12 (3) ◽  
pp. 034016 ◽  
Author(s):  
Yukihiro Hama ◽  
Yoshinori Koyama ◽  
Peter L. Choyke ◽  
Hisataka Kobayashi
Author(s):  
L. A. R. Righesso ◽  
M. Terekhov ◽  
H. Götz ◽  
M. Ackermann ◽  
T. Emrich ◽  
...  

Abstract Objectives Micro-computed tomography (μ-CT) and histology, the current gold standard methods for assessing the formation of new bone and blood vessels, are invasive and/or destructive. With that in mind, a more conservative tool, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), was tested for its accuracy and reproducibility in monitoring neovascularization during bone regeneration. Additionally, the suitability of blood perfusion as a surrogate of the efficacy of osteoplastic materials was evaluated. Materials and methods Sixteen rabbits were used and equally divided into four groups, according to the time of euthanasia (2, 3, 4, and 6 weeks after surgery). The animals were submitted to two 8-mm craniotomies that were filled with blood or autogenous bone. Neovascularization was assessed in vivo through DCE-MRI, and bone regeneration, ex vivo, through μ-CT and histology. Results The defects could be consistently identified, and their blood perfusion measured through DCE-MRI, there being statistically significant differences within the blood clot group between 3 and 6 weeks (p = 0.029), and between the former and autogenous bone at six weeks (p = 0.017). Nonetheless, no significant correlations between DCE-MRI findings on neovascularization and μ-CT (r =−0.101, 95% CI [−0.445; 0.268]) or histology (r = 0.305, 95% CI [−0.133; 0.644]) findings on bone regeneration were observed. Conclusions These results support the hypothesis that DCE-MRI can be used to monitor neovascularization but contradict the premise that it could predict bone regeneration as well.


2014 ◽  
Author(s):  
David S Smith ◽  
Xia Li ◽  
Lori R Arlinghaus ◽  
Thomas E Yankeelov ◽  
E. Brian Welch

We present a fast, validated, open-source toolkit for processing dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data. We validate it against the Quantitative Imaging Biomarkers Alliance (QIBA) Standard and Extended Tofts-Kety phantoms and find near perfect recovery in the absence of noise, with an estimated 10-20x speedup in run time compared to existing tools. To explain the observed trends in the fitting errors, we present an argument about the conditioning of the Jacobian in the limit of small and large parameter values. We also demonstrate its use on an in vivo data set to measure performance on a realistic application. For a 192 x 192 breast image, we achieved run times of < 1 s. Finally, we analyze run times scaling with problem size and find that the run time per voxel scales as O(N1.9), where N is the number of time points in the tissue concentration curve. DCEMRI.jl was much faster than any other analysis package tested and produced comparable accuracy, even in the presence of noise.


2002 ◽  
Vol 1 (3) ◽  
pp. 153535002002021
Author(s):  
Nick G. Costouros ◽  
Dominique Lorang ◽  
Yantian Zhang ◽  
Marshall S. Miller ◽  
Felix E. Diehn ◽  
...  

Current methods of studying angiogenesis are limited in their ability to serially evaluate in vivo function throughout a target tissue. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and pharmacokinetic modeling provide a useful method for evaluating tissue vasculature based on contrast accumulation and washout. While it is often assumed that areas of high contrast enhancement and washout comprise areas of increased angiogenesis and tumor activity, the actual molecular pathways that are active in such areas are poorly understood. Using DCE-MRI in a murine subcutaneous tumor model, we were able to perform pharmacokinetic functional analysis of a tumor, coregistration of MRI images with histological cross-sections, immunohistochemistry, laser capture microdissection, and genetic profiling of tumor heterogeneity based on pharmacokinetic parameters. Using imaging as a template for biologic investigation, we have not found evidence of increased expression of proangiogenic modulators at the transcriptional level in either distinct pharmacokinetic region. Furthermore, these regions show no difference on histology and CD31 immunohistochemistry. However, the expression of ribosomal proteins was greatly increased in high enhancement and washout regions, implying increased protein translation and consequent increased cellular activity. Together, these findings point to the potential importance of posttranscriptional regulation in angiogenesis and the need for the development of angiogenesis-specific contrast agents to evaluate in vivo angiogenesis at a molecular level.


2020 ◽  
Vol 17 (1) ◽  
Author(s):  
Inge C. M. Verheggen ◽  
Joost J. A. de Jong ◽  
Martin P. J. van Boxtel ◽  
Alida A. Postma ◽  
Frans R. J. Verhey ◽  
...  

Abstract Background Circumventricular organs (CVOs) are small structures without a blood–brain barrier surrounding the brain ventricles that serve homeostasic functions and facilitate communication between the blood, cerebrospinal fluid and brain. Secretory CVOs release peptides and sensory CVOs regulate signal transmission. However, pathogens may enter the brain through the CVOs and trigger neuroinflammation and neurodegeneration. We investigated the feasibility of dynamic contrast-enhanced (DCE) MRI to assess the CVO permeability characteristics in vivo, and expected significant contrast uptake in these regions, due to blood–brain barrier absence. Methods Twenty healthy, middle-aged to older males underwent brain DCE MRI. Pharmacokinetic modeling was applied to contrast concentration time-courses of CVOs, and in reference to white and gray matter. We investigated whether a significant and positive transfer from blood to brain could be measured in the CVOs, and whether this differed between secretory and sensory CVOs or from normal-appearing brain matter. Results In both the secretory and sensory CVOs, the transfer constants were significantly positive, and all secretory CVOs had significantly higher transfer than each sensory CVO. The transfer constants in both the secretory and sensory CVOs were higher than in the white and gray matter. Conclusions Current measurements confirm the often-held assumption of highly permeable CVOs, of which the secretory types have the strongest blood-to-brain transfer. The current study suggests that DCE MRI could be a promising technique to further assess the function of the CVOs and how pathogens can potentially enter the brain via these structures. Trial registration: Netherlands Trial Register number: NL6358, date of registration: 2017-03-24


Radiology ◽  
2012 ◽  
Vol 263 (2) ◽  
pp. 374-382 ◽  
Author(s):  
Habib Rahbar ◽  
Savannah C. Partridge ◽  
Wendy B. DeMartini ◽  
Robert L. Gutierrez ◽  
Kimberly H. Allison ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-11 ◽  
Author(s):  
Dong Wang ◽  
Lori R. Arlinghaus ◽  
Thomas E. Yankeelov ◽  
Xiaoping Yang ◽  
David S. Smith

Purpose. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. Methods. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT), Haar wavelet transform (WT), total variation (TV), second-order total generalized variation (TGVα2), and nuclear norm (NN). We measured the signal-to-error ratio (SER) of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs) of the derived pharmacokinetic parameters Ktrans (volume transfer constant) and ve (extravascular-extracellular volume fraction) across a population of random sampling schemes. Results. NN produced the lowest image error (SER: 29.1), while TV/TGVα2 produced the most accurate Ktrans (CCC: 0.974/0.974) and ve (CCC: 0.916/0.917). WT produced the highest image error (SER: 21.8), while FT produced the least accurate Ktrans (CCC: 0.842) and ve (CCC: 0.799). Conclusion. TV/TGVα2 should be used as temporal constraints for CS DCE-MRI of the breast.


2012 ◽  
Vol 17 (9) ◽  
pp. 1 ◽  
Author(s):  
Cyrus B. Amoozegar ◽  
Tracy Wang ◽  
Matthew B. Bouchard ◽  
Addason F. McCaslin ◽  
Elizabeth M. Hillman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document