scholarly journals The diagnostic value of shear wave elastography for parathyroid lesions and comparison with cervical lymph nodes

2017 ◽  
Vol 19 (4) ◽  
pp. 386 ◽  
Author(s):  
Ahmet Veysel Polat ◽  
Mesut Ozturk ◽  
Behic Akyuz ◽  
Cetin Celenk ◽  
Mehmet Kefeli ◽  
...  

Aims: The aim of this study was to prospectively assess the feasibility of the Virtual Touch tissue imaging quantification (VTIQ) method of shear wave elastography (SWE) for the discrimination of parathyroid lesions and to compare the lesions’ stiffness with that of cervical lymph nodes.Materials and methods: SWE using VTIQ was performed on 66 patients with 87 histopathologically proven parathyroid lesions (54 parathyroid adenomas and 33 parathyroid hyperplasia) and 29 patients with 31 inflammatory cervical lymph nodes. The mean SWVs of the lesions were compared and receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance.Results: The mean SWV of parathyroid adenomas (2.16±0.33 m/s) differed significantly from those of parathyroid hyperplasia and lymph nodes (1.75±0.28 m/s and 1.86±0.37 m/s respectively, p<0.001). Selecting a cutoff value of 1.92 m/s for diagnosing adenoma led to 80% sensitivity and 82% specificity (area under the curve [AUC]: 0.832 [95% confidence interval (CI): 0.742–0.921], p< 0.001).Conclusions: The VTIQ method of SWE can contribute to the differentiation of parathyroid adenoma from parathyroid hyperplasia and cervical lymphnodes.

2021 ◽  
Vol 21 (86) ◽  
pp. e194-e199
Author(s):  
Mustafa Devran Aybar ◽  
◽  
Onder Turna ◽  

Introduction: In this study, we attempt to determine the diagnostic performance of shear wave elastography of the optic nerve and adjacent fat tissue in patients with optic neuritis. Methods: The study included a patient group consisting of 72 eyes of 36 patients who were diagnosed with unilateral optic neuritis, and an age-matched control group of 36 eyes of 18 healthy subjects. The patient group consisted of 25 multiple sclerosis patients and 11 recurrent isolated optic neuritis patients. The mean shear wave elastography values of the optic nerves and intraorbital fat tissue adjacent optic nerves were recorded using m/s and kPa as units. ROC curve analysis was performed, and the diagnostic accuracy of shear wave elastography values was determined. Results: The mean shear wave elastography values of the optic nerves with neuritis (2.49 ± 0.41 m/s and 17.56 ± 4.42 kPa) were significantly higher than the values of the contralateral normal optic nerves (1.71 ± 0.32 m/s and 9.02 ± 2.34 kPa) (p = 0.006 and p = 0.004, respectively) in the optic neuritis group. The mean shear wave elastography values of intraorbital fat tissue adjacent optic nerves with neuritis (1.87 ± 0.32 m/s and 9.65 ± 1.12 kPa) were significantly higher than the values of the contralateral normal side (1.47 ± 0.27 m/s and 6.78 ± 1.14 kPa) (p = 0.025 and p = 0.022, respectively) in the optic neuritis group. ROC curve analysis showed a high diagnostic accuracy for determining optic neuritis with shear wave elastography values of the optic nerves (AUC 0.955 [95% CI, 0.933–0.978] in m/s and AUC 0.967 [95% CI, 0.940–0.985] in kPa). Conclusions: Shear wave elastography may be an important alternative diagnostic tool in the diagnosis of optic neuritis.


2019 ◽  
Vol 48 (6) ◽  
pp. 20180454 ◽  
Author(s):  
Yoshihiko Sasaki ◽  
Ichiro Ogura

Objectives: To evaluate shear wave elastography in differentiating between benign and malignant cervical lymph nodes in patients with oral carcinoma. Methods: 77 patients with oral squamous cell carcinoma were examined by B-mode and shear wave elastography with a 14 MHz linear transducer. The integrated shear wave elastography software allowed the operator to place regions of interest of various sizes within the elastography window, and automatically displayed shear elastic modulus data (kPa) for each region of interest. The relationship between size and shear elastic modulus of cervical lymph nodes was assessed by Pearson's rank correlation test. The shear elastic modulus of cervical lymph nodes in benign and malignant were evaluated using the Mann–Whitney U test. The analyses were used with a 5% significance level. Results: We plotted shear elastic modulus (X) against minimal axial diameter of cervical lymph nodes (Y), and observed a significant correlation [ Y = 0.091 X + 4.648 (R2 = 0.603, p = 0.000, N = 77)]. Furthermore, the shear elastic modulus of the malignant cervical lymph nodes (105.9 ± 5.2 kPa) was higher than that of benign (11.9 ± 4.4 kPa, p = 0.000). Conclusions: The shear wave elastography is an effective technique for the objectively and quantitatively diagnosis of cervical lymph node metastases of the oral carcinoma.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Ioana Golu ◽  
Ioan Sporea ◽  
Lavinia Moleriu ◽  
Anca Tudor ◽  
Marioara Cornianu ◽  
...  

Background and Aims. 2D-shear wave elastography (2D-SWE) is a relatively new elastographic technique. The aim of the present study is to determine the values of the elasticity indexes (EI) measured by 2D-SWE in parathyroid benign lesions (adenomas or hyperplasia) and to establish if this investigation is helpful for the preoperative identification of the parathyroid adenoma. Material and Methods. The study groups were represented by 22 patients with primary or tertiary hyperparathyroidism, diagnosed by specific tests, and 43 healthy controls, in whom the thyroid parenchyma was evaluated, in order to compare the EI of the thyroid tissue with those of the parathyroid lesions. Results. The mean EI measured by 2D-SWE in the parathyroid lesions was 10.2 ± 4.9 kPa, significantly lower than that of the normal thyroid parenchyma (19.5 ± 7.6 kPa; p=0.007), indicating soft tissue. For a cutoff value of 12.5 kPa, the EI assessed by 2D-SWE had a sensitivity of 93% and a specificity of 86% (AUC = 0.949; p<0.001) for predicting parathyroid lesions. Conclusion. A value lower than 12.5 kPa for the mean EI measured by 2D-SWE can be used to confirm that the lesion/nodule is a parathyroid adenoma.


2017 ◽  
Vol 45 (2) ◽  
pp. 251-259 ◽  
Author(s):  
Jun You ◽  
Juan Chen ◽  
Feixiang Xiang ◽  
Yue Song ◽  
Simai Khamis ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Jan Heřman ◽  
Zuzana Sedláčková ◽  
Tomáš Fürst ◽  
Jaromír Vachutka ◽  
Richard Salzman ◽  
...  

Aim. To evaluate the prognostic value of ultrasound and shear-wave elastography (SWE) in diagnosing malignant cervical lymph nodes. Methods. A total of 99 patients with enlarged lymph nodes (99 lymph nodes presenting as a neck mass) were examined clinically with conventional ultrasound including Doppler examination and shear-wave elastography. The results of the examinations were compared with the final diagnosis. Results. There were 43 benign and 56 malignant lymph nodes in our cohort. Age and sex were significant predictors of malignancy. The standard ultrasound parameters—node size, long/short axis ratio, hilum, vascularization, and the presence of microcalcifications—were also statistically significant. Lymph node volume combined with age showed the best predictive power. The maximum stiffness found on SWE was also a significant predictor of malignancy. The combination of epidemiologic, classic ultrasound, and elastographic parameters yielded the highest sensitivity and specificity in the prediction of malignancy; however, the additional impact of elastographic parameters was low. Conclusion. A combination of epidemiologic and classic ultrasound parameters can discriminate between malignant and benign lymph nodes with satisfactory sensitivity and specificity. Examining the stiffness of lymph nodes by means of SWE does not add much new predictive power.


2016 ◽  
Vol 42 (6) ◽  
pp. 1273-1281 ◽  
Author(s):  
Ghobad Azizi ◽  
James M. Keller ◽  
Michelle L. Mayo ◽  
Kelé Piper ◽  
David Puett ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-11 ◽  
Author(s):  
Laura Cotoi ◽  
Daniela Amzar ◽  
Ioan Sporea ◽  
Andreea Borlea ◽  
Dan Navolan ◽  
...  

Objectives. The aim of the study was to compare elastographic means in parathyroid adenomas, using shear wave elastography and strain elastography. Methods. This prospective study examined 20 consecutive patients diagnosed with primary hyperparathyroidism and parathyroid adenoma, confirmed by biochemical assay, technetium-99 sestamibi scintigraphy, and pathology report, after parathyroid surgery. All patients were examined on conventional 2B ultrasound, 2D shear wave elastography, and strain elastography. We determined using 2D shear wave elastography (SWE) the elasticity index (EI) in parathyroid adenoma, thyroid parenchyma, and surrounding muscle and examined using strain elastography the parathyroid adenoma, and determined the strain ratio with the thyroid tissue and muscle tissue. Results. All patients had positive sestamibi scintigraphy and underwent surgery, with confirmation of parathyroid adenoma in all cases. The mean parathormone (PTH) value before surgery was 153.29 pg/ml (36.5, 464.8) and serum calcium concentration was 10.5 mg/dl (9, 11.5). We compared using 2D-SWE and strain elastography parathyroid adenoma with thyroid tissue and with surrounding muscle. The mean EI measured by SWE in parathyroid adenoma was 4.74 ± 2.74 kPa and in thyroid parenchyma was 11.718 ± 4.206 kPa (mean difference = 6.978 kPa, p<0.001), and the mean EI value in muscle tissue was 16.362 ± 3.829 kPa (mean difference = 11.622, p<0.001). Using ROC analysis, we found that an EI below 7 kPa correctly identifies parathyroid tissue. We evaluated parathyroid adenomas using strain elastography by color mapping and strain ratio as a semiquantitative measurement; however, we could not find any statistical correlation comparing the strain ratio obtained from the parathyroid adenoma with the thyroid tissue (p=0.485). Conclusion. Ultrasound elastography is a helpful tool in identifying parathyroid adenomas. A cutoff value below 7 kPa can be used in 2D-SWE. Color maps in strain elastography without adding strain ratio can be used, parathyroid adenoma being identified as score 1 in the Rago criteria.


Sign in / Sign up

Export Citation Format

Share Document