Collagen Fiber Re-Alignment and Mechanical Properties in a Mouse Supraspinatus Tendon Model: Examining Changes With Age and Location

Author(s):  
Kristin S. Miller ◽  
Brianne K. Connizzo ◽  
Elizabeth Feeney ◽  
Louis J. Soslowsky

One postulated mechanism of tendon structural response to mechanical load is collagen fiber re-alignment. Recently, where collagen fiber re-alignment occurs during a tensile mechanical test has been shown to vary by tendon age and location in a postnatal developmental mouse supraspinatus tendon (SST) model [1]. It is thought that as the tendon matures and its collagen fibril network, collagen cross-links and collagen-matrix interactions develop, its ability to respond quickly to mechanical stimuli hastens [1]. Additionally, the insertion site and midsubstance of postnatal SST may develop differently and at different rates, providing a potential explanation for differences in fiber re-alignment behaviors at the insertion site and midsubstance at postnatal developmental time points [1]. However, collagen fiber re-alignment behavior, in response to mechanical load at a mature age and in comparison to developmental ages, have not been examined. Therefore, the objectives of this study are to locally measure: 1) fiber re-alignment during preconditioning and tensile mechanical testing and 2) to compare local differences in collagen fiber alignment and corresponding mechanical properties to address tissue response to mechanical load in the mature and postnatal developmental mouse SST. We hypothesize that 1) 90 day tendons will demonstrate the largest shift in fiber re-alignment during preconditioning, but will also re-align during the toe- and linear-regions. Additionally, we hypothesize that 2) mechanical properties and initial collagen fiber alignment will be greater in the midsubstance of the tendon compared to the tendon-to-bone insertion site at 90 days, 3) that mechanical properties will increase with age, and that 4) collagen fiber organization at the insertion site will decrease with age.

Author(s):  
Kristin S. Miller ◽  
Lena Edelstein ◽  
Louis J. Soslowsky

Cyclic preconditioning is a commonly accepted initial component of any tendon testing protocol. Preconditioning provides tendons with a consistent “history” and stress-strain results become repeatable allowing for rigorous evaluation and comparison. While it is widely accepted that preconditioning is important, changes that occur during preconditioning are not well understood. Micro-structural alterations, such as re-arrangement of collagen fibers, is one proposed mechanism of preconditioning [1,4]. However, this mechanism has not been examined. Therefore, the objective of this study is to locally measure: 1) fiber re-alignment during preconditioning, stress relaxation and tensile testing and 2) corresponding mechanical properties, to address mechanisms of preconditioning as well as tissue nonlinearity and inhomogeneity in the rat supraspinatus tendon. We hypothesize that 1) fiber re-alignment will be greatest in the toe region, but will also occur during preconditioning and 2) mechanical properties and initial collagen fiber alignment will be greater in the midsubstance location of the tendon compared to the tendon-to-bone insertion site.


2013 ◽  
Vol 135 (2) ◽  
Author(s):  
Brianne K. Connizzo ◽  
Joseph J. Sarver ◽  
Renato V. Iozzo ◽  
David E. Birk ◽  
Louis J. Soslowsky

Collagen fiber realignment is one mechanism by which tendon responds to load. Re-alignment is altered when the structure of tendon is altered, such as in the natural process of aging or with alterations of matrix proteins, such as proteoglycan expression. While changes in re-alignment and mechanical properties have been investigated recently during development, they have not been studied in (1) aged tendons, or (2) in the absence of key proteoglycans. Collagen fiber re-alignment and the corresponding mechanical properties are quantified throughout tensile mechanical testing in both the insertion site and the midsubstance of mouse supraspinatus tendons in wild type (WT), decorin-null (Dcn-/-), and biglycan-null (Bgn-/-) mice at three different ages (90 days, 300 days, and 570 days). Percent relaxation was significantly decreased with age in the WT and Dcn-/- tendons, but not in the Bgn-/- tendons. Changes with age were found in the linear modulus at the insertion site where the 300 day group was greater than the 90 day and 570 day group in the Bgn-/- tendons and the 90 day group was smaller than the 300 day and 570 day groups in the Dcn-/- tendons. However, no changes in modulus were found across age in WT tendons were found. The midsubstance fibers of the WT and Bgn-/- tendons were initially less aligned with increasing age. The re-alignment was significantly altered with age in the WT tendons, with older groups responding to load later in the mechanical test. This was also seen in the Dcn-/- midsubstance and the Bgn-/- insertion, but not in the other locations. Although some studies have found changes in the WT mechanical properties with age, this study did not support those findings. However, it did show fiber re-alignment changes at both locations with age, suggesting a breakdown of tendon's ability to respond to load in later ages. In the proteoglycan-null tendons however, there were changes in the mechanical properties, accompanied only by location-dependent re-alignment changes, suggesting a site-specific role for these molecules in loading. Finally, changes in the mechanical properties did not occur in concert with changes in re-alignment, suggesting that typical mechanical property measurements alone are insufficient to describe how structural alterations affect tendon's response to load.


2012 ◽  
Vol 134 (3) ◽  
Author(s):  
Kristin S. Miller ◽  
Lena Edelstein ◽  
Brianne K. Connizzo ◽  
Louis J. Soslowsky

Repeatedly and consistently measuring the mechanical properties of tendon is important but presents a challenge. Preconditioning can provide tendons with a consistent loading history to make comparisons between groups from mechanical testing experiments. However, the specific mechanisms occurring during preconditioning are unknown. Previous studies have suggested that microstructural changes, such as collagen fiber re-alignment, may be a result of preconditioning. Local collagen fiber re-alignment is quantified throughout tensile mechanical testing using a testing system integrated with a polarized light setup, consisting of a backlight, 90 deg-offset rotating polarizer sheets on each side of the test sample, and a digital camera, in a rat supraspinatus tendon model, and corresponding mechanical properties are measured. Local circular variance values are compared throughout the mechanical test to determine if and where collagen fiber re-alignment occurred. The inhomogeneity of the tendon is examined by comparing local circular variance values, optical moduli and optical transition strain values. Although the largest amount of collagen fiber re-alignment was found during preconditioning, significant re-alignment was also demonstrated in the toe and linear regions of the mechanical test. No significant changes in re-alignment were seen during stress relaxation. The insertion site of the supraspinatus tendon demonstrated a lower linear modulus and a more disorganized collagen fiber distribution throughout all mechanical testing points compared to the tendon midsubstance. This study identified a correlation between collagen fiber re-alignment and preconditioning and suggests that collagen fiber re-alignment may be a potential mechanism of preconditioning and merits further investigation. In particular, the conditions necessary for collagen fibers to re-orient away from the direction of loading and the dependency of collagen reorganization on its initial distribution must be examined.


2019 ◽  
Vol 61 (2) ◽  
pp. 190-204 ◽  
Author(s):  
Pedro Huebner ◽  
Paul B. Warren ◽  
Daniel Chester ◽  
Jeffrey T. Spang ◽  
Ashley C. Brown ◽  
...  

2020 ◽  
Vol 8 (7_suppl6) ◽  
pp. 2325967120S0044
Author(s):  
Ryan Castile ◽  
Spencer Lake ◽  
Robert Brophy ◽  
Ronak Patel

Objectives: The anterolateral ligament (ALL) of the knee has recently emerged as a potential contributor to rotational stability of the knee, with growing interest in ALL reconstruction as a supplement to anterior cruciate ligament reconstruction. The prevalence of the ALL in the knee has varied in anatomic dissection and imaging studies, raising questions about its importance as a knee stabilizer. The purpose of this study was to assess the microstructural and mechanical properties of the anterolateral knee, to better understand the ALL structure compared to the surrounding anterolateral capsule (ALC) and lateral collateral ligament (LCL). A polarized light imaging technique was used to quantify collagen fiber alignment simultaneously with measurement of tensile mechanical properties. Our primary hypothesis was that there is no difference in the microstructural and mechanical properties between the ALL and ALC. Our secondary hypothesis was that the properties of the LCL are different from the ALL and ALC. Methods: Twenty-five knee specimens from sixteen donors (five males, eleven females; mean age 45.6 +/- 6.4; age range 35-59 years; mean BMI 26.5 +/- 8.4) were obtained as determined by a priori power analysis. The anatomic technique to dissect the anterolateral knee structures was performed as described previously. Three tissue samples (LCL, ALL, and ALC) were harvested (Fig. 1). The ALL was taken as a quadrilateral piece of tissue starting posterior/proximal from the lateral femoral epicondyle and ending at the lateral border of Gerdy’s tubercle. During gross dissection, the knee was assessed for the presence or absence of a distinct visible and palpable structure within the area defined as the ALL. Harvested samples were thinned to approximately 1-mm thick using a freezing-stage sliding microtome. Cross-sectional area was measured using a 3D laser scanning system. Four 0.8-mm diameter aluminum beads were attached to the sample surface to enable strain measurement. Mechanical testing was performed with preconditioning followed by both a stress-relaxation test and a quasi-static ramp to failure. Microstructural analysis was performed using transmitted circularly-polarized incident light and a high-resolution, division-of-focal-plane polarization camera. The average degree of linear polarization (AVG DoLP; i.e., mean strength of collagen alignment) and standard deviation of the angle of polarization (STD AoP; i.e., degree of variation in collagen angle orientation) were calculated for the region of interest of each sample. Statistical analysis was performed using Kruskal-Wallis test (assuming nonparametric data) with Dunn’s correction for multiple comparisons. Results: Mechanical analysis of elastic moduli for the toe- and linear-region of the stress-strain curves showed no difference between the ALL and ALC but were significantly higher for the LCL (p<0.0001; Fig. 2). Microstructural analysis of the ALL and ALC during quasi-static ramp to failure showed no difference in AVG DoLP and STD AoP values at all strain levels (Fig. 3). Larger DoLP values (i.e., stronger collagen fiber alignment) were observed for the LCL than both the ALL and ALC (p<0.0001). Larger STD AoP values (i.e., more variation in collagen orientation) were observed for the ALL and ALC compared to the LCL (p<0.0001; Fig. 3). When looking at correlations between mechanical and microstructural properties (Fig. 4), we found clustering of the LCL data points at high linear modulus and AVG DoLP while the ALL and ALC data points were clustered together. Similarly, we found clustering of the LCL at high linear modulus and low STD AoP while the ALL and ALC were clustered together. Only three of 25 knee specimens (12%) were observed to have a distinct, ligamentous structure in the region of the ALL. Interestingly, these distinct ALL samples (outlined in black on figures) showed relatively larger elastic moduli, higher AVG DoLP, and lower STD AoP (i.e., uniform and organized collagen alignment) across the stress-strain curve compared to samples harvested from knees without a distinct ALL. The distinct ALL tissues were also seen clustered near the LCL data points in the correlation plots. Conclusions: Overall, there were no differences in the mechanical and microstructural properties between the ALL and ALC, while the LCL demonstrated different properties compared to both the ALL and ALC. Both the ALC and ALL show significantly weaker collagen fiber alignment and more variation in the direction of collagen fiber alignment compared to the LCL. These findings suggest that the ALL has similar properties to capsule (i.e., ALC). However, when a distinct ALL was present at dissection (12%), the data indicates stronger and more uniform collagen alignment suggestive of more ligament-type qualities. Further research is needed to more precisely define the prevalence and properties of distinct ALLs in the knee.


Author(s):  
Carrie A. Voycheck ◽  
Patrick J. McMahon ◽  
Richard E. Debski

The glenohumeral joint is frequently dislocated in the anterior direction causing injury to the anteroinferior (axillary pouch, anterior band of the inferior glenohumeral ligament (AB-IGHL)) capsule. [1, 2] When unloaded, the axillary pouch consists of randomly oriented collagen fibers. These fibers play a pertinent role in its function to resist loading in multiple directions during dislocation at the extreme ranges of motion. [3] Maximum principle strain directions in the anteroinferior capsule have been shown to align with the AB-IGHL during increasing external rotation, suggesting that the collagen fibers may become more aligned with loading as well. [4] In addition, at positions of increased external rotation, the peak maximum principle strains in the capsule correspond to the location of a common capsular failure known as the Bankart lesion. [4] Further, an increase in collagen fiber alignment with load in the supraspinatus tendon has been shown in the toe region of the load-elongation curve. [5] Therefore, it was hypothesized that increases in the collagen fiber alignment and maximum principle strain would correlate with the location of tissue failure. The objective of this work was to determine the collagen fiber alignment and maximum principle strain in the axillary pouch during uniaxial extension to failure and to determine if these parameters could predict the location of tissue failure.


2007 ◽  
Vol 129 (6) ◽  
pp. 880-889 ◽  
Author(s):  
Hsiao-Ying Shadow Huang ◽  
Jun Liao ◽  
Michael S. Sacks

Within the aortic valve (AV) leaflet resides a population of interstitial cells (AVICs), which serve to maintain tissue structural integrity via protein synthesis and enzymatic degradation. AVICs are typically characterized as myofibroblasts, exhibit phenotypic plasticity, and may play an important role in valve pathophysiology. While it is known that AVICs can respond to mechanical stimuli in vitro, the level of in vivo AVIC deformation and its relation to local collagen fiber reorientation during the cardiac cycle remain unknown. In the present study, the deformation of AVICs was investigated using porcine AV glutaraldehyde fixed under 0–90mmHg transvalvular pressures. The resulting change in nuclear aspect ratio (NAR) was used as an index of overall cellular strain, and dependencies on spatial location and pressure loading levels quantified. Local collagen fiber alignment in the same valves was also quantified using small angle light scattering. A tissue-level finite element (FE) model of an AVIC embedded in the AV extracellular matrix was also used explore the relation between AV tissue- and cellular-level deformations. Results indicated large, consistent increases in AVIC NAR with transvalvular pressure (e.g., from mean of 1.8 at 0mmHg to a mean of 4.8 at 90mmHg), as well as pronounced layer specific dependencies. Associated changes in collagen fiber alignment indicated that little AVIC deformation occurs with the large amount of fiber straightening for pressures below ∼1mmHg, followed by substantial increases in AVIC NAR from 4mmHgto90mmHg. While the tissue-level FE model was able to capture the qualitative response, it also underpredicted the extent of AVIC deformation. This result suggested that additional micromechanical and fiber-compaction effects occur at high pressure levels. The results of this study form the basis of understanding transvalvular pressure-mediated mechanotransduction within the native AV and first time quantitative data correlating AVIC nuclei deformation with AV tissue microstructure and deformation.


2009 ◽  
Vol 131 (5) ◽  
Author(s):  
Michaël J. A. Girard ◽  
J. Crawford Downs ◽  
Claude F. Burgoyne ◽  
J.-K. Francis Suh

The sclera is the white outer shell and principal load-bearing tissue of the eye as it sustains the intraocular pressure. We have hypothesized that the mechanical properties of the posterior sclera play a significant role in and are altered by the development of glaucoma—an ocular disease manifested by structural damage to the optic nerve head. An anisotropic hyperelastic constitutive model is presented to simulate the mechanical behavior of the posterior sclera under acute elevations of intraocular pressure. The constitutive model is derived from fiber-reinforced composite theory, and incorporates stretch-induced stiffening of the reinforcing collagen fibers. Collagen fiber alignment was assumed to be multidirectional at local material points, confined within the plane tangent to the scleral surface, and described by the semicircular von Mises distribution. The introduction of a model parameter, namely, the fiber concentration factor, was used to control collagen fiber alignment along a preferred fiber orientation. To investigate the effects of scleral collagen fiber alignment on the overall behaviors of the posterior sclera and optic nerve head, finite element simulations of an idealized eye were performed. The four output quantities analyzed were the scleral canal expansion, the scleral canal twist, the posterior scleral canal deformation, and the posterior laminar deformation. A circumferential fiber organization in the sclera restrained scleral canal expansion but created posterior laminar deformation, whereas the opposite was observed with a meridional fiber organization. Additionally, the fiber concentration factor acted as an amplifying parameter on the considered outputs. The present model simulation suggests that the posterior sclera has a large impact on the overall behavior of the optic nerve head. It is therefore primordial to provide accurate mechanical properties for this tissue. In a companion paper (Girard, Downs, Bottlang, Burgoyne, and Suh, 2009, “Peripapillary and Posterior Scleral Mechanics—Part II: Experimental and Inverse Finite Element Characterization,” ASME J. Biomech. Eng., 131, p. 051012), we present a method to measure the 3D deformations of monkey posterior sclera and extract mechanical properties based on the proposed constitutive model with an inverse finite element method.


2020 ◽  
Vol 142 (11) ◽  
Author(s):  
Ashley K. Fung ◽  
Snehal S. Shetye ◽  
Yihan Li ◽  
Yilu Zhou ◽  
X. Sherry Liu ◽  
...  

Abstract Pregnant women experience weight gain, gait changes, and biochemical fluctuations that impair joint function and alter the maternal skeleton. Hormonal changes increase pelvic ligament laxity in preparation for childbirth and affect peripheral joint laxity. Calcium demands also rise during pregnancy and lactation, resulting in reduced bone mineral density (BMD) and maternal bone loss. Altered tendon properties and bone loss during pregnancy and lactation may impact tendon insertion sites, such as rotator cuff tendons where insertion site ruptures are common. However, the effects of pregnancy and lactation at the tendon-to-bone interface have not been investigated. Therefore, the objective of this study was to evaluate supraspinatus tendon mechanical properties and insertion site microstructure during pregnancy, lactation, and postweaning recovery in female rats. We hypothesized that pregnancy and lactation would compromise supraspinatus tendon mechanical properties and subchondral bone microstructure. Female rats were divided into virgin, pregnancy, lactation, and recovery groups, and supraspinatus tendons were mechanically evaluated. Surprisingly, tendon mechanics was unaffected by pregnancy and lactation. However, tendon modulus decreased two-weeks postweaning. Additionally, tendons failed by bony avulsion at the insertion site, and the lactation group exhibited reduced failure properties corresponding to decreased subchondral bone mineralization. Lactation also resulted in dramatic bone loss at the epiphysis, but trabecular bone microarchitecture recovered postweaning. In conclusion, lactation following pregnancy impaired trabecular bone microstructure and subchondral bone mineralization, leading to reduced supraspinatus tendon-to-bone insertion site failure properties. These findings will contribute toward understanding the pathogenesis of tendon-to-bone disorders.


Sign in / Sign up

Export Citation Format

Share Document