Regurgitant Commissure Flow Through a Closed Polymeric Heart Valve

Author(s):  
Scott C. Corbett ◽  
Hamid N.-Hashemi ◽  
Ahmet U. Coskun

While heart valve prostheses have been used successfully since 1960, outcomes are far from ideal. The underlying problem with bioprostheses is a limited life from structural changes such as calcification and leaflet wear, leading to valve failure. The underlying problem with mechanical heart valves is the presence of flow disturbances which necessitate anticoagulation. A polyurethane valve has the potential to improve upon the shortcomings of existing valves and ultimately improve patient survival.

Author(s):  
Scott C. Corbett ◽  
Neil Verma ◽  
Parnian Boloori Zadeh ◽  
Ahmet U. Coskun ◽  
Hamid N.-Hashemi

While heart valve prostheses have been used successfully since 1960, 10-year survival rates still range from 37–58% [1]. The underlying problem with bioprostheses is a limited life from structural changes such as calcification and leaflet wear, leading to valve failure [2]. Biological tissue fixation and methods used to mount the tissue to a supporting stent can be blamed for this shortcoming. The underlying problem with mechanical heart valves is the presence of a centrally located leaflet, or occluder. It propagates high velocity jets, turbulence and areas of stagnation: the disturbances which necessitate anticoagulation [3]. A polyurethane valve has the potential to improve upon the shortcomings of existing valves and ultimately improve patient survival.


Author(s):  
Wilson Bizimana ◽  
Gloria Akimana ◽  
Arthur Semedo Insumbo ◽  
Hounayda Jerguigue ◽  
Rachida Latib ◽  
...  

AbstractMalignant melanoma of vagina is a rare condition. Its histogenesis has been debated and the positive diagnosis is based on immunohistochemistry. Pelvic magnetic resonance imaging remains the gold standard for assessing locoregional extension status and post-treatment surveillance of melanoma of vagina. The observation concerned a 53-year-old woman with no specific history who presented a primary malignant melanoma of vagina without secondary locations. To date, the case is the second one reported in the literature. Early diagnosis of the malignant melanoma of vagina may improve patient survival because late diagnoses are punctuated by poor prognosis. We have presented epidemiological with etiopathogenic characteristics and described all imaging features to stage the tumor and to conduct the appropriate treatment.


2000 ◽  
Author(s):  
Michael S. Sacks ◽  
Sanjay Kaushal ◽  
John E. Mayer

Abstract The need for improved heart valve prostheses is especially critical in pediatric applications, where growth and remodeling are essential. Tissue engineered heart valves (TEHV) have functioned in the pulmonary circulation of growing lambs for up to four months [1], and thus can potentially overcome limitations of current bioprosthetic heart valves. Despite these promising results, significant questions remain. In particular, the role of scaffold mechanical properties in optimal extra-cellular matrix development, as well as TEHV durability, are largely unexplored. We have previously demonstrated flexure testing as a sensitive and critical test for BHV tissue mechanical property evaluation [2]. The following study was conducted to determine the feasibility of using this technique to provide fundamental information required for optimizing TEHV scaffold designs.


2013 ◽  
Author(s):  
Marina Rigau ◽  
Blanca Majem ◽  
Tatiana Altadill ◽  
Lucia Lanau ◽  
José-Luis Sánchez-Iglesias ◽  
...  

2019 ◽  
Vol 12 ◽  
pp. 2632010X1983126
Author(s):  
Yuki Nakamura ◽  
Koichi Toda ◽  
Shigeru Miyagawa ◽  
Yasushi Yoshikawa ◽  
Hiroki Hata ◽  
...  

Cardiac sarcoma treatment is challenging for surgeons because of frequent tumor recurrence and poor prognosis. In addition, optimal management of recurrences is not well established. The multi-targeted tyrosine kinase inhibitor, pazopanib, was recently approved for soft-tissue sarcoma. Herein, we present a case involving recurrent cardiac angiosarcoma where the patient survived for 2 years with complete remission of disease after repeated surgical resection and treatment with oral pazopanib. Based on our experience, aggressive surgical resection combined with pazopanib may be a valid treatment for recurrent cardiac angiosarcoma to improve patient survival.


2006 ◽  
Vol 26 (5) ◽  
pp. 543-551 ◽  
Author(s):  
Hironori Tanaka ◽  
Kazuhiro Nouso ◽  
Haruhiko Kobashi ◽  
Yoshiyuki Kobayashi ◽  
Shin-ichiro Nakamura ◽  
...  

Author(s):  
Wei Sun ◽  
Hengchu Cao ◽  
Jim Davidson ◽  
Michael Sacks

Previous research has suggested that the structural deterioration in porcine bioprosthetic heart valves (BHV) may be correlated with the regions of high tensile and bending stresses acting on the leaflets during opening and closing[1, 2]. Stress concentrations within the cusp can either directly accelerate tissue structural fatigue damage, or initiate calcification by causing structural disintegration, enabling multiple pathways of calcification that can lead to valve failure[3,4]. In the case of bovine pericardial heart valve prostheses, structural failure of the leaflets is rare but calcification has been observed. Although details of the process are unclear, it is generally assumed that the design of the pericardial valve, which gives a stress-reduced state of the leaflets, is likely to provide improved performance in long-term applications.


Author(s):  
M J King ◽  
T David ◽  
J Fisher

The effect of leaflet opening angle on flow through a bileaflet mechanical heart valve has been investigated using computational fluid dynamics (CFD). Steady state, laminar flow for a Newtonian fluid at a Reynolds number of 1500 was used in the two-dimensional model of the valve, ventricle, sinus and aorta. This computational model was verified using one-dimensional laser Doppler velocimetry (LDV). Although marked differences in the flow fields and energy dissipation of the jets downstream of the valve were found between the CFD predictions and the three-dimensional experimental model, both methods showed similar trends in the changes of the flow fields as the leaflet opening angle was altered. As the opening angle increased the area of recirculating fluid downstream of the leaflets, the pressure drop across the valve and the volumetric flow rate through the outer orifice decreased. For opening angles greater than 80° the jet through the outer orifice recombined with the central jet downstream of the leaflet; for an opening angle of 78° the jet through the outer orifice impinged on the aortic wall before recombining with the central jet. This study suggests that the opening angle has a marked effect on the flow downstream of the bileaflet mechanical heart valve and that valves with opening angles greater than 80° are preferable.


2017 ◽  
Vol 14 (3) ◽  
pp. 3035-3038 ◽  
Author(s):  
Aldo Pezzuto ◽  
Fabrizio Terzo ◽  
Maria Laura Graziani ◽  
Alberto Ricci ◽  
Pierdonato Bruno ◽  
...  

2012 ◽  
Vol 61 (5) ◽  
pp. 10-24
Author(s):  
Aleksandr Davidovich Makatsariya ◽  
Viktoriya Omarovna Bitsadze ◽  
Dzhamilya Khizriyevna Khizroyeva ◽  
Vyacheslav Borisovich Nemirovskiy ◽  
Svetlana Vladimirovna Akinshina

In patients with prosthetic heart valves pregnancy and labor are associated with high risk. There are no established anticoagulation guidelines in pregnant women with mechanical heart valve prostheses. More often physiological hypercoagulable state during pregnancy can reveal acquired and/or inherited hemostasis abnormalities which were asymptotic before pregnancy. The presence in the history of patients the foetal loss syndrome, severe obstetric complications (severe preeclampsia, abruptio placenta, antenatal fetal death, feto-placental insufficiency), thrombosis events is an indication for the screening for genetic thrombophilia and antiphospholipid syndrome. The diagnosis of thrombophilia in patients with mechanical heart valve prostheses can explain the inefficiency of anticoagulation therapy, warfarin resistance, «floating» hemostasis markers and difficulties in adequate dose selection


Sign in / Sign up

Export Citation Format

Share Document