3D CFD Simulation of Water Hammer Through a 90° Bend: Applicability of URANS, 3D Effects and Unsteady Friction

Author(s):  
Stefan Riedelmeier ◽  
Stefan Becker ◽  
Eberhard Schlücker

In most cases, the method of characteristics is used to calculate the propagation of water hammer in hydraulic systems due to the size of those pipings, although three-dimensional effects are known to occur. In order to investigate and quantify these effects, a three-dimensional computational fluid dynamics simulation of water hammer through a bend geometry was performed. For the resolution of the developing high spatial and temporal gradients an adequate mesh and suitable physical model was generated using a commercial code. The applicability of unsteady Reynolds-averaged Navier-Stokes simulation was evaluated considering the turbulent properties of the flow using results from the literature. Furthermore velocity, pressure, wall shear stress and vorticity distributions are presented. The effect of the 90° bend as three-dimensional element was identified and the impact on the flow field is presented. In the end, the annular effect is discussed. Due to the high forces of inertia in the boundary layer and the dominating viscous forces close to the wall, high velocity gradients are developing resulting in high wall shear stresses. It is shown that the viscous and turbulent transport of momentum in the radial direction reduces these velocity gradients and limits the maximum occurring wall shear stress.

2002 ◽  
Vol 14 (04) ◽  
pp. 164-170 ◽  
Author(s):  
YANG-YAO NIU ◽  
WEI-KUANG CHU ◽  
LUNG-CHENG LEE ◽  
HSI-YU YU

In this study, Newtonian flows passing through three-dimensional curved and straight axissymmetrical stenotic tubes are investigated. The geometry effects and Reynolds numbers of 100, 200, 400, and 600 on the formation of the shear rate over arterial walls are studied. It is noted that geometric effects on flow features such as velocity profiles, pressure and wall shear stress distributions in the post-stenotic region are significant. The location of maximum wall shear stress is found to relate to the geometric effect much than the Reynolds number effect.


2017 ◽  
Vol 83 (24) ◽  
Author(s):  
Xia Luo ◽  
Sabrina S. Jedlicka ◽  
Kristen L. Jellison

ABSTRACT This study investigated Cryptosporidium parvum oocyst deposition onto biofilms as a function of shear stress under laminar or turbulent flow. Annular rotating bioreactors were used to grow stabilized stream biofilms at shear stresses ranging from 0.038 to 0.46 Pa. These steady-state biofilms were then used to assess the impact of hydrodynamic conditions on C. parvum oocyst attachment. C. parvum deposition onto biofilms followed a pseudo-second-order model under both laminar (after a lag phase) and turbulent flows. The total number of oocysts attached to the biofilm at steady state decreased as the hydrodynamic wall shear stress increased. The oocyst deposition rate constant increased with shear stress but decreased at high shear, suggesting that increasing wall shear stress results in faster attachment of Cryptosporidium due to higher mass transport until the shear forces exceed a critical limit that prevents oocyst attachment. These data show that oocyst attachment in the short and long term are impacted differently by shear: higher shear (to a certain limit) may be associated with faster initial oocyst attachment, but lower shear is associated with greater numbers of oocysts attached at equilibrium. IMPORTANCE This research provides experimental evidence to demonstrate that shear stress plays a critical role in protozoan-pathogen transport and deposition in environmental waters. The data presented in this work expand scientific understanding of Cryptosporidium attachment and fate, which will further influence the development of timely and accurate sampling strategies, as well as advanced water treatment technologies, to target protozoan pathogens in surface waters that serve as municipal drinking water sources.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
E M J Hartman ◽  
A M Kok ◽  
A Hoogendoorn ◽  
F J H Gijsen ◽  
A F W Steen ◽  
...  

Abstract Introduction Local wall shear stress (WSS) metrics, high local lipid levels (as detected by near-infrared spectroscopy (NIRS)), as well as systemic lipid levels, have been individually associated with atherosclerotic disease progression. However, a possible synergistic effect remains to be elucidated. This study is the first study to combine WSS metrics with NIRS-detected local lipid content to investigate a potential synergistic effect on plaque progression in human coronary arteries. Methods The IMPACT study is a prospective, single centre study investigating the relation between atherosclerotic plaque progression and WSS in human coronary arteries. Patients with ACS treated with PCI were included. At baseline and after 1-year follow-up, patients underwent near-infrared spectroscopy intravascular ultrasound (NIRS-IVUS) imaging and intravascular doppler flow measurements of at least one non-culprit coronary artery. After one month, a CT angiography was made. CT derived centreline combined with IVUS lumen contours resulted in a 3D reconstruction of the vessel. The following WSS metrics were computed using computational fluid dynamics applying the vessel specific invasive flow measurements: time-average wall shear stress (TAWSS), relative residence time (RRT), cross-flow index, oscillatory shear index and transverse wall shear stress. Low TAWSS is known as pro atherogenic, in contrast to all the other shear stress metrics, at which a high magnitude is pro-atherogenic. The arteries were divided into 1.5mm/45° sectors. Based on NIRS-IVUS, wall thickness change over time was determined and NIRS positive sectors detected. Furthermore, per vessel the shear stress was divided into tertiles (low, intermediate, high). To investigate the synergistic effect of local lipids on shear stress related plaque growth, wall thickness change over time was related to the different shear stress metrics comparing the NIRS-positive with the NIRS-negative sectors. Results 15 non-culprit coronary arteries from the first 14 patients were analyzed (age 62±10 years old and 92.9% male). A total of 2219 sectors were studied (5.2%, N=130, NIRS-positive) for wall thickness changes. After studying all five shear stress metrics, we found for TAWSS and RRT that presence of lipids, as detected by NIRS, amplified the effect of shear stress on plaque progression (see figure). Sectors presenting with lipid-rich plaque, compared to NIRS-negative sectors, showed more progression when they were exposed to low TAWSS (p=0.07) or high RRT (p=0.012) and more regression in sectors exposed to high TAWSS (p=0.10) or low RRT (p=0.06). Delta wall thickness vs shear stress Conclusion We presented the first preliminary results of the IMPACT study, showing the synergistic effect of lipid rich plaque and shear stress on plaque progression. Therefore, intravascular lipid-rich plaque (NIRS) assessment has added value to shear stress profiling for the prediction of plaque growth, leading to improved risk stratification. Acknowledgement/Funding ERC starting grant 310457


Circulation ◽  
2014 ◽  
Vol 129 (6) ◽  
pp. 673-682 ◽  
Author(s):  
Riti Mahadevia ◽  
Alex J. Barker ◽  
Susanne Schnell ◽  
Pegah Entezari ◽  
Preeti Kansal ◽  
...  

1994 ◽  
Vol 116 (3) ◽  
pp. 645-649 ◽  
Author(s):  
Josef Daniel Ackerman ◽  
Louis Wong ◽  
C. Ross Ethier ◽  
D. Grant Allen ◽  
Jan K. Spelt

We present a Preston tube device that combines both total and static pressure readings for the measurement of wall shear stress. As such, the device facilitates the measurement of wall shear stress under conditions where there is streamline curvature and/or over surfaces on which it is difficult to either manufacture an array of static-pressure taps or to position a single tap. Our “Preston-static” device is easily and conveniently constructed from commercially available regular and side-bored syringe needles. The pressure difference between the total pressure measured in the regular syringe needle and the static pressure measured in the side-bored one is used to determine the wall shear stress. Wall shear stresses measured in pipe flow were consistent with independently determined values and values obtained using a conventional Preston tube. These results indicate that Preston-static tubes provide a reliable and convenient method of measuring wall shear stress.


2000 ◽  
Vol 123 (2) ◽  
pp. 134-144 ◽  
Author(s):  
Sujata Prakash ◽  
C. Ross Ethier

Computational techniques are widely used for studying large artery hemodynamics. Current trends favor analyzing flow in more anatomically realistic arteries. A significant obstacle to such analyses is generation of computational meshes that accurately resolve both the complex geometry and the physiologically relevant flow features. Here we examine, for a single arterial geometry, how velocity and wall shear stress patterns depend on mesh characteristics. A well-validated Navier-Stokes solver was used to simulate flow in an anatomically realistic human right coronary artery (RCA) using unstructured high-order tetrahedral finite element meshes. Velocities, wall shear stresses (WSS), and wall shear stress gradients were computed on a conventional “high-resolution” mesh series (60,000 to 160,000 velocity nodes) generated with a commercial meshing package. Similar calculations were then performed in a series of meshes generated through an adaptive mesh refinement (AMR) methodology. Mesh-independent velocity fields were not very difficult to obtain for both the conventional and adaptive mesh series. However, wall shear stress fields, and, in particular, wall shear stress gradient fields, were much more difficult to accurately resolve. The conventional (nonadaptive) mesh series did not show a consistent trend towards mesh-independence of WSS results. For the adaptive series, it required approximately 190,000 velocity nodes to reach an r.m.s. error in normalized WSS of less than 10 percent. Achieving mesh-independence in computed WSS fields requires a surprisingly large number of nodes, and is best approached through a systematic solution-adaptive mesh refinement technique. Calculations of WSS, and particularly WSS gradients, show appreciable errors even on meshes that appear to produce mesh-independent velocity fields.


Author(s):  
Xin Deng ◽  
Brian Weaver ◽  
Cori Watson ◽  
Michael Branagan ◽  
Houston Wood ◽  
...  

Oil-lubricated bearings are widely used in high speed rotating machines such as those used in the aerospace and automotive industries that often require this type of lubrication. However, environmental issues and risk-adverse operations have made water lubricated bearings increasingly popular. Due to different viscosity properties between oil and water, the low viscosity of water increases Reynolds numbers drastically and therefore makes water-lubricated bearings prone to turbulence effects. The turbulence model is affected by eddy-viscosity, while eddy-viscosity depends on wall shear stress. Therefore, effective wall shear stress modeling is necessary in producing an accurate turbulence model. Improving the accuracy and efficiency of methodologies of modeling eddy-viscosity in the turbulence model is important, especially considering the increasingly popular application of water-lubricated bearings and also the traditional oil-lubricated bearings in high speed machinery. This purpose of this paper is to study the sensitivity of using different methodologies of solving eddy-viscosity for turbulence modeling. Eddy-viscosity together with flow viscosity form the effective viscosity, which is the coefficient of the shear stress in the film. The turbulence model and Reynolds equation are bound together to solve when hydrodynamic analysis is performed, therefore improving the accuracy of the turbulence model is also vital to improving a bearing model’s ability to predict film pressure values, which will determine the velocity and velocity gradients in the film. The velocity gradients in the film are the other term determining the shear stress. In this paper, three approaches applying Reichardt’s formula were used to model eddy-viscosity in the fluid film. These methods are for determining where one wall’s effects begin and the other wall’s effects end. Trying to find a suitable model to capture the wall’s effects of these bearings, with aim to improve the accuracy of the turbulence model, would be of high value to the bearing industry. The results of this study could aid in improving future designs and models of both oil and water lubricated bearings.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Anna Starikov ◽  
Guanglei Xiong ◽  
James K Min

Introduction: The ability to detect hemodynamically significant coronary artery disease non-invasively has been a goal that has the potential to improve patient care significantly. New non-invasive approaches using coronary CT angiograms (CCTAs) have been proposed and appear to show some promise. Hypothesis: One such method is the measurement of measuring wall shear stress (WSS), the tangential force of flowing blood against the artery wall, using computational fluid dynamics (CFD). However, in order to deem this technique useful in clinical practice, the normal values must first be defined. These values have been minimally reported and are limited to the left coronary tree. Methods: We ran a CFD simulation of WSS on 3-D reconstructions of the coronary arteries derived from the CCTAs of 35 patients with either no disease or non-obstructive (< 50%) stenosis from the DeFACTO trial, a multi-center study. The resulting model was segmented according to the Society of Cardiovascular CT guidelines, separating the proximal and distal parts of each artery as well as the major side branches. The segments were composed of WSS values at hundreds of points along the vessel wall. The median value was taken as a representative of each segment. Results: The average values were calculated and varied significantly from one another, especially the proximal and distal parts of the same artery, as showing in Figure 1. Conclusions: These results establish the first known WSS distribution within all of the coronary arteries and serve as a foundation for defining a cut-off for abnormal values. Importantly, they also illuminate the variability of WSS that occurs even throughout a single artery and suggests that perhaps multiple abnormal cutoffs need to be established to evaluate WSS based on the location of the stenosis.


2018 ◽  
Vol 152 ◽  
pp. 02004 ◽  
Author(s):  
Jacky Ling ◽  
Felicia Wong Yen Myan

Biofouling is the accumulation of unwanted material on surfaces submerged or semi submerged over an extended period. This study investigates the antifouling performance of a new bioinspired topography design. A shark riblets inspired topography was designed with Solidworks and CFD simulations were antifouling performance. The study focuses on the fluid flow velocity, the wall shear stress and the appearance of vortices are to be noted to determine the possible locations biofouling would most probably occur. The inlet mass flow rate is 0.01 kgs-1 and a no-slip boundary condition was applied to the walls of the fluid domain. Simulations indicate that Velocity around the topography averaged at 7.213 x 10-3 ms-1. However, vortices were observed between the gaps. High wall shear stress is observed at the peak of each topography. In contrast, wall shear stress is significantly low at the bed of the topography. This suggests the potential location for the accumulation of biofouling. Results show that bioinspired antifouling topography can be improved by reducing the frequency of gaps between features. Linear surfaces on the topography should also be minimized. This increases the avenues of flow for the fluid, thus potentially increasing shear stresses with surrounding fluid leading to better antifouling performance.


Sign in / Sign up

Export Citation Format

Share Document