Study of the Effect of Buoyancy on Flow and Heat Transfer of Supercritical Pressure Water in Horizontal Pipes

Author(s):  
Shuiqing Yu ◽  
Huixiong Li ◽  
Xianliang Lei ◽  
Yifan Zhang ◽  
Tingkuan Chen

The present paper is devoted to clarify the effect of buoyancy on the flow and heat transfer of supercritical pressure water flowing in horizontal pipes at supercritical pressures. A series of experiments have been designed and carried out in Xi’an Jiaotong University, Xi’an, China to obtain data in relation to flow and heat transfer of supercritical pressure water in pipes with different arrangements. The experimental parameters are as follows: pressures ranging from 23 to 28MPa, heat flux being up to 600 kW/m2, and the fluid mass fluxes being in the range from 100 to 1000kg/(m2s). In this study, distributions of the local wall temperatures and the local heat transfer coefficients around the circumference of the tube are measured at different cross-sections along the flowing direction. On the basis of the experimental data obtained in the study, some criteria available in open literatures, including Gr/Re2.7, Gr/Re2, and Grq/Grth, are employed to estimate the magnitude of buoyancy and the effect of buoyancy on the flow and heat transfer behavior of the supercritical fluid. It is showed that buoyancy is of particular importance for horizontal flows, but play significantly different role in different regions having different characteristics of the specific heat capacity. Strong buoyancy effect exists in the large specific heat region, but in the enthalpy region which is far away from the LSHR, the discrepancy between the temperature of the top wall and that of the bottom wall is small, indicating that the buoyancy effect can be negligible. Based on the present study, it was found that the criteria Grq/Grth is better than others in terms of the capability of evaluating the effect of the buoyancy on the flow and heat transfer of supercritical water.

Author(s):  
Xiangfei Kong ◽  
Huixiong Li ◽  
Changjiang Liao ◽  
Xianliang Lei ◽  
Qian Zhang

Supercritical pressure water has been widely used in many industrial fields, such as fossil-fired power plants and nuclear reactors because mainly of its high thermal efficiencies. Although many empirical correlations for heat transfer coefficients of supercritical pressure water have been proposed by different authors based on different experimental data base, there exist remarkable discrepancies between the predicted heat transfer coefficients of different correlations under even the same condition. Heat transfer correlations with good prediction performance are of considerable significance for developing supercritical (ultra-supercritical) pressure boilers and SCWRs. In this paper, the experimental data (about 7389 experimental data points) and 30 existing empirical correlations for heat transfer of supercritical pressure water (SCW) flowing in vertical upward tubes are collected from the open literatures. Evaluations of the prediction performance of the existing correlations are conducted based on the collected experimental data, and a detailed multi-collinearity analysis has been made on different correction factors involved in the existing correlations, and then based on the collected experimental data, a new heat transfer correlation is developed for the supercritical pressure water flowing in vertical upward tubes under normal and enhanced heat transfer mode. Compared with the existing correlations, the new correlation exhibits good prediction accuracy, with a mean absolute deviation (MAD) of 9.63%.


Author(s):  
Chen-Ru Zhao ◽  
Pei-Xue Jiang ◽  
Han-Liang Bo

In this paper, experimental flow and heat transfer data of supercritical pressure HCFC22 flowing in a uniformly heated smooth tube with inner diameter of 1.004 mm at p/pc=1.1 obtained by the authors are analyzed accounting for the influence of the thermophysical properties variation, the buoyancy effect, as well as the flow acceleration effect due to thermal expansion. These analyses indicate that both of the sharp thermophysical properties variation in the fluid adjacent to the wall with low density, low specific heat and low thermal conductivity and the flow acceleration effect due to thermal expansion have significant negative effects on the heat transfer under the present study conditions for HCFC22, while for the friction factor, the thermophysical properties variation is the predominant factor. The buoyancy effect on the flow and heat transfer is negligible. A new semi-empirical local heat transfer correlation accounting for the thermophysical properties variation and the flow acceleration effect due to thermal expansion for supercritical pressure fluids flowing through a vertical small tube during heating is proposed. The predicted values agree with 95% of the measured data within ±25%. In addition, a flow correlation with thermophysical properties variation correction terms to predict the friction factors for supercritical pressure fluids is proposed which predicts the measured friction factors within ±25%.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4327
Author(s):  
Min-Seob Shin ◽  
Santhosh Senguttuvan ◽  
Sung-Min Kim

The present study experimentally and numerically investigates the effect of channel height on the flow and heat transfer characteristics of a channel impingement cooling configuration for various jet Reynolds numbers in the range of 2000–8600. A single array consisting of eleven jets with 0.8 mm diameter injects water into the channel with 2 mm width at four different channel heights (3, 4, 5, and 6 mm). The average heat transfer coefficients at the target surface are measured by maintaining a temperature difference between the jet exit and the target surface in the range of 15–17 °C for each channel height. The experimental results show the average heat transfer coefficient at the target surface increases with the jet Reynolds number and decreases with the channel height. An average Nusselt number correlation is developed based on 85 experimentally measured data points with a mean absolute error of less than 4.31%. The numerical simulation accurately predicts the overall heat transfer rate within 10% error. The numerical results are analyzed to investigate the flow structure and its effect on the local heat transfer characteristics. The present study advances the primary understanding of the flow and heat transfer characteristics of the channel impingement cooling configuration with liquid jets.


Author(s):  
Chen-Ru Zhao ◽  
Zhen Zhang ◽  
Han-Liang Bo ◽  
Pei-Xue Jiang

Investigations and numerical modelling are performed on the heat transfer to CO2 at supercritical pressure under buoyancy affected conditions during heating in a vertical tube with inner diameter of 2 mm. Numerical modelling are carried out using several low Reynolds number (LRN) k-ε models, including the model due to Launder and Sharma (LS), Abe, Kondoh and Nagano (AKN), Myong and Kasagi (MK) models. The numerical results are compared with the corresponding experimental data and the predicted values using the semi-empirical correlation for convection heat transfer of supercritical fluids without deterioration. The abilities of various LRN models to predict the heat transfer to fluids at supercritical pressures under normal and buoyancy affected heat transfer conditions are evaluated. Detailed information related to the flow and turbulence is presented to get better understanding of the mechanism of the heat transfer deterioration due to buoyancy, as well as the different behavior of various LRN turbulence models in responding to the buoyancy effect, which gives clues in future model improvement and development to predict the buoyancy affected heat transfer more precisely and in a broader range of conditions as they come to be used to simulate the flow and heat transfer in various applications such as in the supercritical pressure water-cooled reactor (SCWR) and the supercritical pressure steam generator in the high temperature gas cooled reactor (HTR).


1970 ◽  
Vol 92 (3) ◽  
pp. 490-497 ◽  
Author(s):  
J. W. Ackerman

Investigations of heat transfer to supercritical pressure fluids have been going on for some time, and correlations have been developed for both free and forced-convection conditions. In these investigations, unpredictable heat transfer performance has sometimes been observed when the pseudocritical temperature of the fluid is between the temperature of the bulk fluid and that of the heated surface. The unusual performance has been attributed to many causes, but one for which more evidence is being collected is that of a pseudofilm-boiling process similar to film boiling which occurs at subcritical pressures. This paper, which is an extension of work reported earlier on forced-convection heat transfer to supercritical pressure water, presents experimental evidence which suggests that a pseudofilm-boiling phenomenon can occur in smooth-bore tubes. During the period from 1963–1966, tubes with ID’s from 0.37 to 0.96 in. were tested at pressures from 3300–6000 psia and at heat fluxes and mass velocities in the range of interest in steam-generator design. The effects of heat flux, mass velocity, tube diameter, pressure, and bulk fluid temperature on both the occurrence and characteristics of pseudofilm boiling are discussed. Results of a second series of tests conducted in 1967, which show that ribbed tubes suppress pseudofilm boiling at supercritical pressure much like they do film boiling at subcritical pressures, are also discussed.


1972 ◽  
Vol 94 (4) ◽  
pp. 355-359 ◽  
Author(s):  
E. O. Stoffel ◽  
J. R. Welty

The effects of square and reentrant entrances on flow regimes (no “appreciable” separation, large transitory stall, and fully developed two-dimensional stall) and local heat-transfer coefficients were determined with air flowing through a symmetrical, plane-wall, two-dimensional subsonic diffuser with one of the diverging walls heated and maintained isothermal. Flow and heat-transfer studies were made for the following ranges: 2θ = 0 to 45 deg, L/W = 6 to 18, and Rextut = 4 × 104 to 3 × 105. Results indicated that 2θ, L/W, and entrance configuration greatly affected the flow regime and heat transfer. Equations relating Um′ to Ut, Ur to Ut, and equations of the type Nu = C Pr0.6Rex0.8 are presented. For the configurations tested, heat-transfer rates were greater for reentrant than for square entrances.