An Experimental Study on Flow Boiling Characteristics of pHEMA Nano-Coated Surfaces in a Microchannel

Author(s):  
Abdolali Khalili Sadaghiani ◽  
Yağmur Şişman ◽  
Gözde Özaydın İnce ◽  
Ali Koşar

In this study, the effect of pHEMA (Polyhydroxyethylmethacrylate) nanostructure coated surfaces on flow boiling was investigated in a rectangular microchannel. Experiments were conducted using deionized water as the working fluid to investigate flow boiling in a microchannel with dimensions of 14 cm length, 1.5 cm width, and 500 μm depth. The effect of pHEMA coatings (coated on 1.5 × 1.5 cm2 silicon plates) on heat transfer coefficients and flow patterns was assessed and supported using a high speed camera system. Although the contact angle decreases on nano-coated surfaces, due to surface porosity, boiling heat transfer coefficient increases. Furthermore, visualization results indicated that uncoated surfaces experienced a smaller nucleate boiling region. It was also observed that dryout occurs at higher heat fluxes for coated surfaces.

Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer and the steady state critical heat fluxes (CHFs) in a short vertical SUS304-tube for the flow velocities (u = 17.28 to 40.20 m/s), the inlet liquid temperatures (Tin = 293.30 to 362.49 K), the inlet pressures (Pin = 842.90 to 1467.93 kPa) and the exponentially increasing heat input (Q = Q0 exp(t/τ), τ = 10 s) were systematically measured by the experimental water loop comprised of a multistage canned-type circulation pump with high pump head. The SUS304 test tubes of inner diameters (d = 3 and 6 mm), heated lengths (L = 33 and 59.5 mm), effective lengths (Leff = 23.3 and 49.1 mm), L/d (= 11 and 9.92), Leff/d (= 7.77 and 8.18), and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) are used in this work. The inner surface temperature and the heat flux from non-boiling to CHF were clarified. The subcooled boiling heat transfer for SUS304 test tube was compared with our Platinum test tube data and the values calculated by other workers’ correlations for the subcooled boiling heat transfer. The influence of flow velocity on the subcooled boiling heat transfer and the CHF is investigated into details and the widely and precisely predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical SUS304-tube is given based on the experimental data. The correlation can describe the subcooled boiling heat transfer coefficients obtained in this work within 15% difference. Nucleate boiling surface superheats for the SUS304 test tube become very high. Those at the high liquid Reynolds number are close to the lower limit of Heterogeneous Spontaneous Nucleation Temperature. The dominant mechanisms of the flow boiling CHF in a short vertical SUS304-tube are discussed.


Author(s):  
Ankit Kalani ◽  
Satish G. Kandlikar

Flow boiling with microchannel can dissipate high heat fluxes at low surface temperature difference. A number of issues, such as instabilities, low critical heat flux (CHF) and low heat transfer coefficients, have prevented it from reaching its full potential. A new design incorporating open microchannels with uniform and tapered manifold (OMM) was shown to mitigate these issues successfully. Distilled, degassed water at 80 mL/min is used as the working fluid. Plain and open microchannel surfaces are used as the test sections. Heat transfer and pressure drop performance for uniform and tapered manifold with both the surfaces are discussed. A low pressure drop of 7.5 kPa is obtained with tapered manifold and microchannel chip at a heat flux of 263 W/cm2 without reaching CHF. The pressure drop data is further compared with the homogenous model and the initial results are presented.


Author(s):  
Maritza Ruiz ◽  
Claire M. Kunkle ◽  
Jorge Padilla ◽  
Van P. Carey

This study presents an experimental exploration of flow boiling heat transfer in a spiraling radial inflow microchannel heat sink. The effect of surface wettability, fluid subcooling levels, and mass fluxes are considered in this type of heat sink for use in applications with high fluxes up to 300 W/cm2. The design of the heat sink provides an inward radial swirl flow between parallel, coaxial disks that form a microchannel of 300 μm and 1 cm radius with a single inlet and a single outlet. The channel is heated on one side through a copper conducting surface, while the opposite side is essentially adiabatic to simulate a heat sink scenario for electronics cooling. Flow boiling heat transfer and pressure drop data were obtained for this heat sink device using water at near atmospheric pressure as the working fluid for inlet subcooling levels from 20 to 81°C and mean mass flux levels ranging from 184 to 716 kg/m2s. To explore the effects of varying surface wetting, experiments were conducted with two different heated surfaces. One was a clean, machined copper surface with water equilibrium contact angles in the range of 14–40°, typical of common metal surfaces. The other was a surface coated with zinc oxide nanostructures that are superhydrophilic with equilibrium contact angles measured below 10°. During boiling, increased wettability resulted in quicker rewetting and smaller bubble departure diameter as indicated by reduced temperature oscillations during boiling and achieving higher maximum heat flux without dryout. Reducing inlet subcooling levels was also found to reduce the magnitude of oscillations in the oscillatory boiling regime. The highest heat transfer coefficients were seen in fully developed boiling with low subcooling levels as a result of heat transfer being dominated by nucleate boiling. The highest heat fluxes achieved were during partial subcooled flow boiling at 300 W/cm2 with an average surface temperature of 134 °C and requiring a pumping power to heat rate ratio of 0.01%. The hydrophilic surface retained wettability after a series of boiling tests. Recommendations for use of this heat sink design in high flux applications is also discussed.


Author(s):  
Peipei Chen ◽  
Barclay G. Jones ◽  
Ty A. Newell

This work reports on experimental studies to visualize nucleate boiling on the enhanced heat transfer surface of the hypervapotron for with application in the International Thermonuclear Experiment Reactor [ITER]. This research uses the simulant fluid Freon (R134A) instead of prototypic water to model the system performance. This results in much lower thermophysical conditions to represent the prototypic phenomena. By using reduced pressure, temperatures, etc, based on the critical physical properties of both working fluids, Freon and water, the dramatic drop in the level of these quantities with Freon allows the use of modest test conditions. The experiment was conducted for both saturated and subcooled boiling with different heat fluxes (from 50 to 300 kW/m2). A comparison of the heat transfer performance of finned structures and flat surfaces were examined under particular fluid conditions. The uniqueness of this work is the visualization method that allows direct observation of the subcooled boiling process of the Hypervapotron surfaces. Working with a high speed (12,000 frames per second), high fidelity digital camera with variable magnifications (from 1×–25×), the sub-cooled boiling phenomena was observed in detail. A major conclusion of this work is the existence of two separate zones linked to different energy removal efficiency in hypervapotron. Under high heat flux condition, enhanced boiling heat transfer (about 20–30% higher than flat surface) was observed for hypervapotron effect, while saturated boiling happened in the cavity, and a large portion of the region was vapor filled. The process of vapor bubble rotation in the slot appeared to be helpful to enhance energy transfer, as evidenced by an improved wetting condition on the heating surfaces.


2009 ◽  
Vol 131 (12) ◽  
Author(s):  
C.-J. Kuo ◽  
Y. Peles

Flow boiling was experimentally studied using coolant HFE-7000 for two types of parallel microchannels: a plain-wall microchannel and a microchannel with structured reentrant cavities on the side walls. Flow morphologies, boiling inceptions, heat transfer coefficients, and critical heat fluxes were obtained and studied for mass fluxes ranging from G=164 kg/m2 s to G=3025 kg/m2 s and mass qualities (energy definition) ranging from x=−0.25 to x=1. Comparisons of the performance of the enhanced and plain-wall microchannels were carried out. It was found that reentrant cavities were effective in reducing the superheat at the onset of nucleate boiling and increasing the heat transfer coefficient. However, they did not seem to increase the critical heat flux.


2019 ◽  
Vol 141 (3) ◽  
Author(s):  
Kan Zhou ◽  
Hua Zhu ◽  
Wei Li ◽  
Junye Li ◽  
Kuang Sheng ◽  
...  

Recently, microchannel heat sinks have been emerged as a kind of high performance cooling scheme to meet the heat dissipation requirement of electronics packaging and integration. In this study, an experimental investigation of subcooled flow boiling in a high-aspect-ratio rectangular microchannel was conducted with de-ionized water as the working fluid. In the experimental operations, the mass flux was varied from 200 to 400 kg/m2s and the imposed heat flux from 3 to 20 W/cm2 while the fluid inlet temperature was regulated constantly at 90 °C. The boiling curves, onset of nucleate boiling (ONB), and flow patterns of subcooled flow boiling were investigated with the aid of instrumental measurements and a high-speed camera. The slope of the boiling curves increased sharply once the superheat needed to initiate the onset of nucleate boiling was attained, with lower superheat required of boiling incipience for lower mass fluxes. Meanwhile, the initiative superheat and heat flux of onset of nucleate boiling were compared with the existing correlations in the literature with good agreement. As for the flow visualization images, slug flow and reverse backflow were observed, where transient local dryout as well as rewetting occurred. A facile image processing tool was developed to profile the transient development and progression of the liquid–vapor interface and partial dryout patches in microchannels, which proved that the physical quantities of bubble dynamics for the elongation period during subcooled boiling could be well detected and calculated.


Author(s):  
Benjamin J. Jones ◽  
Suresh V. Garimella

The influence of surface roughness on flow boiling heat transfer and pressure drop in microchannels is experimentally explored. The microchannel heat sink employed in the study consists of 10 parallel, 25.4 mm long channels with nominal dimensions of 500 μm × 500 μm. The channels were produced by saw-cutting. Two of the test piece surfaces were roughened to varying degrees with electrical discharge machining (EDM). The roughness average, Ra, varied from 1.4 μm for the as-fabricated, saw-cut surface to 3.9 and 6.7 μm for the two roughened EDM surfaces. Deionized water was used as the working fluid. Experiments indicate that the surface roughness has little influence on boiling incipience and only a minor impact on saturated boiling heat transfer coefficients at lower heat fluxes. For wall heat fluxes above 1500 kW/m2, the two EDM surfaces (3.9 and 6.7 μm) have similar heat transfer coefficients that were 20 to 35% higher than those measured for the saw cut surface (1.4 μm). Analysis of the pressure drop measurements indicates that only the roughest surface (6.7 μm) has an adverse effect on the two-phase pressure drop.


2018 ◽  
Vol 17 (2) ◽  
pp. 57
Author(s):  
H. L. S. L. Leão ◽  
D. B. Marchetto ◽  
G. Ribatski

A comparative study of the performance of of refrigerants R134a, R407C, R245fa and R600a during flow boiling was performed for a 123x494 µm2 heat sink composed of 50 parallel rectangular microchannels. Heat transfer experimental results for heat fluxes up to 310 kW/m2, mass velocities from 300 to 800 kg/(m2 s), liquid subcoolings of 5 and 10 °C and saturation temperature close to 30 ºC were obtained. Global heat transfer coefficients (footprint) up to 10 kW/(m2 °C) were found. The liquid superheating necessary for the onset of nucleate boiling (ONB) was also characterized, and the fluids R245fa and R407C presented the highest and lowest, respectively, superheating to trigger the boiling process. Moreover, for a fixed averaged vapor quality, the average effective heat transfer coefficient increases with increasing mass velocity and liquid subcooling. The refrigerants R600a and R407C presented the highest and the lowest heat transfer coefficients, respectively. Five heat transfer predictive methods from literature provided accurate predictions of the data for R134a, R245fa and R600a, capturing most of the data trends. No one method provided accurate predictions of the heat transfer coefficient data of R407C.


Author(s):  
Francisco J. do Nascimento ◽  
Hugo L. S. L. Leão ◽  
Gherhardt Ribatski

In the present study, the thermal performance of a micro heat spreader based on flow boiling mechanism was evaluated. The heat spreader under study has a foot print area of 15 × 15 mm2 and is composed by 50 channels with width of 100 μm and depth of 500 μm. Experiments were performed for R134a, heat fluxes up to 310 kW/m2 (based on the foot print area), mass velocities from 400 to 1500 kg/m2s, saturation temperatures of approximately 25°C and liquid subcoolings of 5 and 15°C. Heat-sink averaged heat transfer coefficients based on the effective heat transfer area up to 9 kW/m2K were obtained. From the analyses of the experimental results, for a fixed heat-spreader averaged wall superheating, it was found that the dissipated heat flux increases with decreasing the mass velocity and liquid subcooling. Moreover, the trend with varying mass velocity of the difference between the heat spreader averaged superheating for the onset of nucleate boiling (ONB) and the respective value under boiling conditions is not clear, however it seems that its value increases with increasing the liquid subcooling. The wall superheating excess necessary for the onset of nucleate boiling becomes negligible for mass velocities higher than 1000 kg/m2s.


1962 ◽  
Vol 84 (4) ◽  
pp. 365-371 ◽  
Author(s):  
H. S. Swenson ◽  
J. R. Carver ◽  
G. Szoeke

In large, subcritical pressure, once-through power boilers heat is transferred to steam and water mixtures ranging in steam quality from zero per cent at the bottom of the furnace to 100 per cent at the top. In order to provide design information for this type of boiler, heat-transfer coefficients for forced convection film boiling were determined for water at 3000 psia flowing upward in a vertical stainless-steel tube, AISI Type 304, having an inside diameter of 0.408 inches and a heated length of 6 feet. Heat fluxes ranged between 90,000 and 180,000 Btu/hr-sq ft and were obtained by electrical resistance heating of the tube. The operation of the experimental equipment was controlled so that nucleate boiling, transition boiling, and stable film boiling occurred simultaneously in different zones of the tube. The film boiling data were correlated with a modified form of the equation Nu = a a(Re)m(Pr)n using steam properties evaluated at inside surface temperature. Results of a second series of heat-transfer tests with tubes having a helical rib on the inside surface showed that nucleate boiling could be maintained to much higher steam qualities with that type of tube than with a smooth-bore tube.