Life Estimation of Carbon Overcoat on Magnetic Media for Heat-Assisted Magnetic Recording Using Novel Raman Spectroscopy

Author(s):  
M. Yanagisawa ◽  
M. Kunimoto ◽  
T. Homma

A heat-assisted magnetic recording (HAMR) is expected for a future high density recording of a hard disk drive. However, a carbon overcoat (COC) composed of diamond-like carbon (DLC) or a lubricant film is possibly damaged when a magnetic medium, i.e. CoPt alloy, is heated at around Curie temperature (Tc) of 600K by a near-field HAMR head. We carried out HAMR simulation experiments by using newly developed Raman spectroscopic systems, composed of plasmonic sensors for surface-enhanced Raman scattering (SERS), a pulsed laser heating, and an in-situ temperature measurement with an intensity ratio of anti-Stokes/Stokes lines. It was found that the heated temperature of the COC is higher than that of the magnetic film, i.e., 580 °C and 366 °C, respectively. Intensity changes of G-band peak in Raman spectra for DLC films were observed during the pulsed laser heating. The Raman intensity was exponentially decreased by oxidation in air, where time constants were calculated as a parameter of a pulse width. Degradation life of the DLC film can be estimated from a critical pulse width, where the time constant is extrapolated to zero. The estimated pulse width for no degradation was 250μs at the heating temperature of 580 °C. The result shows no damage can be estimated in DLC films for HAMR because the effective irradiation time is 5ns and the accumulated irradiation time is 0.5ms in HAMR operations.

2014 ◽  
Vol 115 (17) ◽  
pp. 17B701 ◽  
Author(s):  
B. X. Xu ◽  
Z. H. Cen ◽  
J. H. Goh ◽  
J. M. Li ◽  
Y. T. Toh ◽  
...  

2013 ◽  
Vol 53 (1) ◽  
pp. 303-310 ◽  
Author(s):  
Y. S. Ma ◽  
Y. J. Man ◽  
M. Shakerzadeh ◽  
H. L. Seet ◽  
R. Ji ◽  
...  

Author(s):  
M. Yanagisawa ◽  
M. Kunimoto ◽  
T. Homma

A plasmonic sensor is used for emulation of near field transducer (NFT). Some overcoat films (thickness of 1nm) were coated on Au nanoparticles (NPs) on a convex quartz glass substrate (plasmonic sensor). Heating behavior of the films was examined by laser heating using novel Raman spectroscopic tools, i.e. surface-enhanced Raman scattering (SERS) with the plasmonic sensor, a continuous laser heating tool, in-situ observation of spectra and temperature with a high speed time-resolved measurement. The heating temperature of tetrahedral carbon (ta-C) film in He gas is lower than that in air. This is because the thermal conductivity of He is larger than air. Few spectral change of ta-C film (thickness of 1nm) on Au NP’s is observed except initial change in around 100 s at the temperature around 500 °C, which corresponds to the temperature of the carbon overcoat (COC) for the media temperature of 327 °C (600K, Currie temperature for CoPt alloy). Some carbide films, i.e. SiC, TiC, and WC, showed high heat resistance, that is, few spectral change was observed. It is found that lubricant is evaporated from the COC on magnetic media and transferred to the plasmonic sensor.


2016 ◽  
Vol 52 (2) ◽  
pp. 1-6 ◽  
Author(s):  
Yansheng Ma ◽  
Rong Ji ◽  
Yijun Man ◽  
Maziar Shakerzadeh ◽  
Rongyan Zheng ◽  
...  

Carbon ◽  
1999 ◽  
Vol 37 (2) ◽  
pp. 231-239 ◽  
Author(s):  
Randy L Vander Wal ◽  
Mun Y Choi

RSC Advances ◽  
2015 ◽  
Vol 5 (85) ◽  
pp. 69651-69659 ◽  
Author(s):  
S. K. Deb Nath

In heat assisted magnetic recording (HAMR) system, heating of the hard disk magnetic layer is carried out by applying laser rays during the movement of the read/write head over the carbon overcoat for the purpose of reading and writing on its magnetic layer.


2000 ◽  
Author(s):  
D. H. Chen ◽  
Z. M. Zhang

Abstract A simplified finite element model is built to study the thermal response of the 193-nm pulsed-laser calorimeter. The nonequivalence between pulsed-laser heating and electrical heating is estimated to be 0.46% at the thermocouple locations by comparing the calibration factors for average-power laser heating and electrical heating. This study should help the development of calibration and measurement standards in pulsed energy measurements for deep ultraviolet excimer lasers that are important for photolithographic and materials processing applications.


2009 ◽  
Vol 108 (2) ◽  
pp. 125-130 ◽  
Author(s):  
V. V. Girzhon ◽  
A. V. Smolyakov ◽  
N. G. Babich ◽  
M. P. Semen’ko

Sign in / Sign up

Export Citation Format

Share Document