Measured Performance of Building Integrated Photovoltaic Panels: Round 2

Solar Energy ◽  
2004 ◽  
Author(s):  
Brian P. Dougherty ◽  
A. Hunter Fanney ◽  
Mark W. Davis

Architects, building designers, and building owners presently lack sufficient resources for thoroughly evaluating the economic impact of building integrated photovoltaics (BIPV). The National Institute of Standards and Technology (NIST) is addressing this deficiency by evaluating computer models used to predict the electrical performance of BIPV components. To facilitate this evaluation, NIST is collecting long-term BIPV performance data that can be compared against predicted values. The long-term data, in addition, provides insight into the relative merits of different building integrated applications, helps to identify performance differences between cell technologies, and reveals seasonal variations. This paper adds to the slowly growing database of longterm performance data on BIPV components. Results from monitoring eight different building-integrated panels over a twelve-month period are summarized. The panels are installed vertically, face true-south, and are an integral part of the building’s shell. The eight panels comprise the second set of panels evaluated at the NIST test facility. Cell technologies evaluated as part of this second round of testing include single crystalline silicon, polycrystalline silicon, and two thin film materials: tandem-junction amorphous silicon (2-a-Si) and copper-indium-diselenide (CIS). Two 2-a-Si panels and two CIS panels were monitored. For each pair of BIPV panels, one was insulated on its backside while the backside of the second panel was open to the indoor conditioned space. The panel with the backside thermal insulation experienced higher midday operating temperatures. The higher operating temperatures caused a greater dip in maximum power voltage. The maximum power current increased slightly for the 2-a-Si panel but remained virtually unchanged for the CIS panel. Three of the remaining four test specimens were custom-made panels having the same polycrystalline solar cells but different glazings. Two different polymer materials, Tefzel and Kynar, were tested along with 6 mm-thick, low-iron float glass. The two panels having the much thinner polymer front covers consistently outperformed the panel having the glass front. When compared on an annual basis, the energy production of each polymer-front panel was 8.5% higher than the glass-front panel. Comparison of panels of the same cell technology and comparisons between panels of different cell technologies are made on daily, monthly, and annual bases. Efficiency based on coverage area, which excludes the panel’s inactive border, is used for most “between” panel comparisons. Annual coverage-area conversion efficiencies for the vertically-installed BIPV panels range from a low of 4.6% for the 2-a-Si panels to a high of 12.2% for the two polycrystalline panels having the polymer front covers. The insulated single crystalline panel only slightly outperformed the insulated CIS panel, 10.1% versus 9.7%.

2004 ◽  
Vol 127 (3) ◽  
pp. 314-323 ◽  
Author(s):  
Brian P. Dougherty ◽  
A. Hunter Fanney ◽  
Mark W. Davis

Architects, building designers, and building owners presently lack sufficient resources for thoroughly evaluating the economic impact of building integrated photovoltaics (BIPV). The National Institute of Standards and Technology (NIST) is addressing this deficiency by evaluating computer models used to predict the electrical performance of BIPV components. To facilitate this evaluation, NIST is collecting long-term BIPV performance data that can be compared against predicted values. The long-term data, in addition, provides insight into the relative merits of different building integrated applications, helps to identify performance differences between cell technologies, and reveals seasonal variations. This paper adds to the slowly growing database of long-term performance data on BIPV components. Results from monitoring eight different building-integrated panels over a 12-month period are summarized. The panels are installed vertically, face true south, and are an integral part of the building’s shell. The eight panels comprise the second set of panels evaluated at the NIST test facility. Cell technologies evaluated as part of this second round of testing include single-crystalline silicon, polycrystalline silicon, and two thin film materials: tandem-junction amorphous silicon (2-a-Si) and copper-indium-diselenide (CIS). Two 2-a-Si panels and two CIS panels were monitored. For each pair of BIPV panels, one was insulated on its back side while the back side of the second panel was open to the indoor conditioned space. The panel with the back side thermal insulation experienced higher midday operating temperatures. The higher operating temperatures caused a greater dip in maximum power voltage. The maximum power current increased slightly for the 2-a-Si panel but remained virtually unchanged for the CIS panel. Three of the remaining four test specimens were custom-made panels having the same polycrystalline solar cells but different glazings. Two different polymer materials were tested along with 6 mm-thick, low-iron float glass. The two panels having the much thinner polymer front covers consistently outperformed the panel having the glass front. When compared on an annual basis, the energy production of each polymer-front panel was 8.5% higher than the glass-front panel. Comparison of panels of the same cell technology and comparisons between panels of different cell technologies are made on daily, monthly, and annual bases. Efficiency based on coverage area, which excludes the panel’s inactive border, is used for most “between” panel comparisons. Annual coverage-area conversion efficiencies for the vertically-installed BIPV panels range from a low of 4.6% for the 2-a-Si panels to a high of 12.2% for the two polycrystalline panels having the polymer front covers. The insulated single crystalline panel only slightly outperformed the insulated CIS panel, 10.1% versus 9.7%.


2001 ◽  
Vol 123 (3) ◽  
pp. 187-193 ◽  
Author(s):  
A. Hunter Fanney ◽  
Brian P. Dougherty ◽  
Mark W. Davis

The photovoltaic industry is experiencing rapid growth. Industry analysts project that photovoltaic sales will increase from their current $1.5 billion level to over $27 billion by 2020, representing an average growth rate of 25%. (Cook et. al. 2000)[1]. To date, the vast majority of sales have been for navigational signals, call boxes, telecommunication centers, consumer products, off-grid electrification projects, and small grid-interactive residential rooftop applications. Building integrated photovoltaics, the integration of photovoltaic cells into one or more of the exterior surfaces of the building envelope, represents a small but growing photovoltaic application. In order for building owners, designers, and architects to make informed economic decisions regarding the use of building integrated photovoltaics, accurate predictive tools and performance data are needed. A building integrated photovoltaic test bed has been constructed at the National Institute of Standards and Technology to provide the performance data needed for model validation. The facility incorporates four identical pairs of building integrated photovoltaic panels constructed using single-crystalline, polycrystalline, silicon film, and amorphous silicon photovoltaic cells. One panel of each identical pair is installed with thermal insulation attached to its rear surface. The second paired panel is installed without thermal insulation. This experimental configuration yields results that quantify the effect of elevated cell temperature on the panels’ performance for different cell technologies. This paper presents the first set of experimental results from this facility. Comparisons are made between the electrical performance of the insulated and non-insulated panels for each of the four cell technologies. The monthly and overall conversion efficiencies for each cell technology are presented and the seasonal performance variations discussed. Daily efficiencies are presented for a selected month. Finally, plots of the power output and panel temperatures are presented and discussed for the single-crystalline and amorphous silicon panels.


Author(s):  
A. Hunter Fanney ◽  
Brian P. Dougherty ◽  
Mark W. Davis

Abstract The photovoltaic industry is experiencing rapid growth. Industry analysts project that photovoltaic sales will increase from their current $1.5 billion level to over $27 billion by 2020, representing an average growth rate of 25% [1]. To date, the vast majority of sales have been for navigational signals, call boxes, telecommunication centers, consumer products, off-grid electrification projects, and small grid-interactive residential rooftop applications. Building integrated photovoltaics, the integration of photovoltaic cells into one of more of the exterior surfaces of the building envelope, represents a small but growing photovoltaic application. In order for building owners, designers, and architects to make informed economic decisions regarding the use of building integrated photovoltaics, accurate predictive tools and performance data are needed. A building integrated photovoltaic test bed has been constructed at the National Institute of Standards and Technology to provide the performance data needed for model validation. The facility incorporates four identical pairs of building integrated photovoltaic panels constructed using single-crystalline, polycrystalline, silicon film, and amorphous silicon photovoltaic cells. One panel of each identical pair is installed with thermal insulation attached to its rear surface. The second paired panel is installed without thermal insulation. This experimental configuration yields results that quantify the effect of elevated cell temperature on the panels’ performance for different cell technologies. This paper presents the first set of experimental results from this facility. Comparisons are made between the electrical performance of the insulated and non-insulated panels for each of the four cell technologies. The monthly and overall conversion efficiencies for each cell technology are presented and the seasonal performance variations discussed. Daily efficiencies are presented for a selected month. Finally, hourly plots of the power output and panel temperatures are presented and discussed for the single-crystalline and amorphous silicon panels.


1979 ◽  
Author(s):  
G. TRUMP ◽  
E. JAMES ◽  
R. VETRONE ◽  
R. BECHTEL

2008 ◽  
Vol 2008 ◽  
pp. 1-7 ◽  
Author(s):  
Mantas Povilaitis ◽  
Egidijus Urbonavičius

An issue of the stratified atmospheres in the containments of nuclear power plants is still unresolved; different experiments are performed in the test facilities like TOSQAN and MISTRA. MASPn experiments belong to the spray benchmark, initiated in the containment atmosphere mixing work package of the SARNET network. The benchmark consisted of MASP0, MASP1 and MASP2 experiments. Only the measured depressurisation rates during MASPn were available for the comparison with calculations. When the analysis was performed, the boundary conditions were not clearly defined therefore most of the attention was concentrated on MASP0 simulation in order to develop the nodalisation scheme and define the initial and boundary conditions. After achieving acceptable agreement with measured depressurisation rate, simulations of MASP1 and MASP2 experiments were performed to check the influence of sprays. The paper presents developed nodalisation scheme of MISTRA for the COCOSYS code and the results of analyses. In the performed analyses, several parameters were considered: initial conditions, loss coefficient of the junctions, initial gradients of temperature and steam volume fraction, and characteristic length of structures. Parametric analysis shows that in the simulation the heat losses through the external walls behind the lower condenser installed in the MISTRA facility determine the long-term depressurisation rate.


Author(s):  
Andreas Neumann

DLR operates the High Vacuum Plume Test Facility Göttingen – Electric Thrusters (STG-ET). This electric propulsion test facility has now accumulated several years of EP-thruster testing experience. Special features tailored to electric space propulsion testing like a large vacuum chamber mounted on a low vibration foundation, a beam dump target with low sputtering, and a performant pumping system characterize this facility. The vacuum chamber is 12.2m long and has a diameter of 5m. With respect to accurate thruster testing, the design focus is on accurate thrust measurement, plume diagnostics, and plume interaction with spacecraft components. Electric propulsion thrusters have to run for thousands of hours, and with this the facility is prepared for long-term experiments. This paper gives an overview of the facility, and shows some details of the vacuum chamber, pumping system, diagnostics, and experiences with these components.


2021 ◽  
pp. 2109421
Author(s):  
Xin‐Ming Fan ◽  
Ying‐De Huang ◽  
Han‐Xin Wei ◽  
Lin‐Bo Tang ◽  
Zhen‐Jiang He ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document