Effects of Ultrasonic Flowmeter Internal Diameter Differences on the OSBRA Pipeline Measurement Results

Author(s):  
Ana Lui´sa A. S. Ferreira ◽  
Andre´ Paulo Kotchetkoff Neto ◽  
Ma´rcio Manha˜es Gomes de Almeida

The objective of this paper is to describe the effect of the differences between the pipe and the ultrasonic flowmeter internal diameters on the flow-rate measurement results, and to compare the values found with the differences on the pipe balance. The work included field analysis, numerical simulation and meter calibration. The ultrasonic meter balance differences were the reason for this research. The field analysis presents the balance and internal diameter differences. The numerical simulations comprise one, two and three-path meters with arrangements similar to the OSBRA meters. Three flowmeters were calibrated with water and different internal diameter meter runs. The results of the calibrations were compared with the results of the simulations, and also a comparison was made between the simulations and the actual field measurements. The conclusion is that internal diameter differences may generate differences in the ultrasonic flowmeter result, but the differences expected for OSBRA flowmeter results were less than 0.5% which is significantly less than the observed balance differences.

2000 ◽  
Vol 2000.1 (0) ◽  
pp. 895-896
Author(s):  
Tomomi NISHI ◽  
Yoshiaki TANAKA ◽  
Yumiko SUGIYAMA ◽  
Satoshi FUKUHARA

2021 ◽  
pp. 13-19
Author(s):  
Zhanat А. Dayev ◽  
Gulzhan E. Shopanova ◽  
Bakytgul А. Toksanbaeva

The article deals with one of the important tasks of modern flow measurement, which is related to the measurement of the flow rate and the amount of wet gas. This task becomes especially important when it becomes necessary to obtain information about the separate amount of the dry part of the gas that is contained in the form of a mixture in the wet gas stream. The paper presents the principle of operation and structure of the invariant system for measuring the flow rate of wet gas, which is based on the combined use of differential pressure flowmeters and Coriolis flowmeters. The operation of the invariant wet gas flow rate measurement system is based on the simultaneous application of the multichannel principle and the partial flow measurement method. Coriolis flowmeters and the differential pressure flowmeter are used as the main elements of the system. The proposed measurement system does not offer applications for gases with abundant drip humidity. The article provides information about the test results of the proposed invariant system. The estimation of the metrological characteristics of the invariant system when measuring the flow rate of wet gas is given. The obtained test results of the invariant wet gas flow rate measurement system are relevant for natural gas production, transportation, and storage facilities.


Author(s):  
Mohd. Fua’ad Rahmat ◽  
Wee Lee Yaw

This paper discussed the electrostatic sensors that have been constructed for real–time mass flow rate measurement of particle conveying in a Pneumatic pipeline. Many industrial processes require continuous, smooth, and consistent delivery of solids materials with a high accuracy of controlled flow rate. This requirement can only be achieved by installing a proper measurement system. Electrostatic sensor offers the most inexpensive and simplest means of measuring solids flows in pipes. Key words: Electrostatic sensor, cross-correlation, peripheral velocity


2010 ◽  
Vol 32 (2) ◽  
pp. 345-351 ◽  
Author(s):  
Andreas Gutzeit ◽  
Michael A. Patak ◽  
Constantin von Weymarn ◽  
Nicole Graf ◽  
Aleksis Doert ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document