A Numerical Analysis on the System Impedance in a Fan Cooling System

Author(s):  
Dong-Il Kim ◽  
Ki-So Bok ◽  
Han-Bae Lee

To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance curve and it has been usually examined with the fan tester based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement time and effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated. After determining the system impedance curve, it was compared with experimental results. Also the computational domain of the system was investigated to minimize computational time.

Author(s):  
Gerardo L. Augusto ◽  
Alvin B. Culaba ◽  
Laurence A. Gan Lim

The design criteria of converter cooling system for a 2.5 MW permanent magnet direct-drive wind turbine generator were investigated. Two (2) distribution networks with pipe sizes of DN40 and DN50 were used as basis for fluid flow analysis. The theoretical system pressure drop and system volume flow rate of converter cooling system were calculated using the governing equations of mass conservation, pump performance curve and distribution network characteristics. The system of nonlinear equations was solved using multivariable Newton-Raphson method with the solution vector determined using LU decomposition method. Numerical results suggest that the DN50 pipe provides a pressure drop limit of less than 300 Pa/m in the converter cooling system better than the pressure drop obtained from a DN40 pipe. The system volume flow rate of DN50 pipe was found to be above the operating limit of heat exchanger requirement of 135.30 L/min which needs to dissipate heat with a minimum of 50 kW.


Author(s):  
Kunyuan Zhou ◽  
Mike Wilson ◽  
J. Michael Owen ◽  
Gary Lock

Three-dimensional unsteady computational fluid dynamics (CFD) is applied to the ingestion of fluid from a non-uniform mainstream annulus flow via a rim-seal into a rotor-stator wheel-space. The results provide understanding of the complex flow and information for the development of more efficient computational models and analytical ‘orifice models’. The commercial CFD code CFX has been used to carry out unsteady RANS computations with an SST turbulence model. A scalar equation is employed to represent the seeded tracer gas that can be used in experiments to determine sealing effectiveness, and the variation of effectiveness with sealing flow rate is determined for a simple axial clearance seal and one combination of axial and rotational Reynolds numbers. The computational domain comprises one pitch in a row of stator vanes and rotor blades The rotating blade is accounted for by a sliding interface between the stationary and rotating sections of the model, located downstream of the seal clearance. The unsteady computations confirm that the magnitude of the peak-to-trough pressure difference in the annulus is the principal driving mechanism for ingestion (or ingress) into the wheel-space. This pressure difference is used in orifice models to predict sealing effectiveness; its magnitude however depends on the locations in the annulus and the wheel-space that are chosen for its evaluation as well as the sealing flow rate. The CFD is used to investigate the appropriateness of the locations that are often used to determine the pressure difference. It is shown that maximum ingestion occurs when the static pressure peak produced by the vane combines with that produced by the blade, and that highly swirled ingrested flow could contact both the stator and rotor disk when little sealing flow is provided. The relationships between the unsteady simulations and simplified, more computationally efficient steady computations are also investigated. For the system considered here, ingress is found to be dictated principally by the pressure distribution caused by the vane. The effect of the rotating blade on the pressure distribution in the annulus is investigated by comparing the unsteady results with those for steady models that do not involve a blade. It is found that the presence of the blade increases the pressure asymmetry in the annulus. Although the pressure asymmetry predicted by unsteady and steady models have a similar magnitude, the sealing effectiveness is over-predicted considerably for the corresponding steady model. If a “thin seal” geometric approximation is used in the steady model, however, similar effectiveness results compared with the unsteady model may be obtained much more economically.


2000 ◽  
Author(s):  
Snezana Konecni ◽  
Nathan K. Bultman

Abstract Water flow in cooling channels was simulated using the computational fluid dynamics (CFD) code CFX4. Pressure drop in the cooling channels of the coupled-cavity linac (CCL) cavity was calculated. The effects of the manifold on the pressure drop were studied also. Reducing the pressure drop was a primary goal of this exercise that led to changing the cooling channel entrance regions. Results of this analysis were used in sizing pumps required for the cooling system. For the validation of the simplified numerical model, an experiment was performed to measure the pressure drop in the cooling channels for variable flow rate, using a flow loop. Deionized water was circulated through the test section with a pump and its flow rate was monitored with a turbine flow meter. Pressure was monitored with pressure transducers at five locations including a differential pressure transducer across the test section, and water temperature was taken at the exit of the pump. Pressure drop across the inlet and outlet of the test section was measured and recorded for different flow rates. Flow rate was also monitored and stored simultaneously. From the recorded data, an empirical correlation was derived to describe the pressure drop, dp, as a function of flow rate through the four cooling channels.


1992 ◽  
Vol 114 (1) ◽  
pp. 68-77 ◽  
Author(s):  
C. D. Bertram ◽  
K. S. A. Butcher

This paper examines the assumption that the audible events detected as Korotkov sounds in sphygmomanometry occur when blood pressure equals arm-cuff pressure. Several effects that contribute to discrepancy between these pressures are quantified using an idealised arm-and-cuff system consisting of a thick-walled collapsible tube subject to external compression along a central part of its length. The effects studied are (1) transverse pressure difference, resulting from tissues sustaining a part of the external compression through (a) circumferential bending stiffness and (b) longitudinal curvature of the tensed localised neck at the site of initial collapse, (2) longitudinal pressure difference between upstream pressure and pressure at the collapse point due to both (a) viscous and (b) inertial pressure drop. These effects are found to compensate partially for each other; the pressure within the vessel at the collapse point is less than the cuff pressure, but is also less than the blood pressure at the upstream end of the cuff. All four of the contributing terms increase proportionally to the flow-rate raised to a power greater than one, except the viscous pressure drop. Owing to a progressive shortening of the collapsed neck as flow-rate increases, the viscous term is almost independent of the flow-rate. The overall discrepancy displays less flow-rate dependency and is smaller than some of the terms which contribute to it. This means that considerable accuracy is needed if measurements of the effects are to be used to correct the raw data on cuff pressure at the time of Korotkov sound emission so as to obtain an improved estimate of the blood pressure.


2018 ◽  
Vol 13 (3) ◽  
pp. 1-10 ◽  
Author(s):  
I.Sh. Nasibullayev ◽  
E.Sh Nasibullaeva ◽  
O.V. Darintsev

The flow of a liquid through a tube deformed by a piezoelectric cell under a harmonic law is studied in this paper. Linear deformations are compared for the Dirichlet and Neumann boundary conditions on the contact surface of the tube and piezoelectric element. The flow of fluid through a deformed channel for two flow regimes is investigated: in a tube with one closed end due to deformation of the tube; for a tube with two open ends due to deformation of the tube and the differential pressure applied to the channel. The flow rate of the liquid is calculated as a function of the frequency of the deformations, the pressure drop and the physical parameters of the liquid.


1988 ◽  
Vol 53 (4) ◽  
pp. 788-806
Author(s):  
Miloslav Hošťálek ◽  
Jiří Výborný ◽  
František Madron

Steady state hydraulic calculation has been described of an extensive pipeline network based on a new graph algorithm for setting up and decomposition of balance equations of the model. The parameters of the model are characteristics of individual sections of the network (pumps, pipes, and heat exchangers with armatures). In case of sections with controlled flow rate (variable characteristic), or sections with measured flow rate, the flow rates are direct inputs. The interactions of the network with the surroundings are accounted for by appropriate sources and sinks of individual nodes. The result of the calculation is the knowledge of all flow rates and pressure losses in the network. Automatic generation of the model equations utilizes an efficient (vector) fixing of the network topology and predominantly logical, not numerical operations based on the graph theory. The calculation proper utilizes a modification of the model by the method of linearization of characteristics, while the properties of the modified set of equations permit further decrease of the requirements on the computer. The described approach is suitable for the solution of practical problems even on lower category personal computers. The calculations are illustrated on an example of a simple network with uncontrolled and controlled flow rates of cooling water while one of the sections of the network is also a gravitational return flow of the cooling water.


2021 ◽  
Vol 11 (5) ◽  
pp. 2239
Author(s):  
Hailin Zhao ◽  
Hua Su ◽  
Guoding Chen ◽  
Yanchao Zhang

To solve the high leakage and high wear problems faced by sealing devices in aeroengines under the condition of high axial pressure difference, the two-stage finger seal is proposed in this paper. The finite element method and computational fluid dynamics (FEM/CFD) coupling iterative algorithm of the two-stage finger seal is developed and validated. Then the performance advantages of two-stage finger seal compared to the one-stage finger seal are studied, as well as the leakage and the inter-stage pressure drop characteristics of two-stage finger seal are investigated. Finally, the measure to improve the inter-stage imbalance of pressure drop of two-stage finger seal is proposed. The results show that the two-stage finger seal has lower leakage and lower contact pressure than the one-stage finger seal at high axial pressure difference, but there exists an inter-stage imbalance of pressure drop. Increasing the axial pressure difference and the root mean square (RMS) roughness of finger element can aggravate the imbalance of pressure drop, while the radial displacement excitation of rotor has little influence on it. The results also indicate that the inter-stage imbalance of pressure drop of the two-stage finger seal can be improved by increasing the number of finger elements of the 1st finger seal and decreasing the number of finger elements of the 2nd finger seal.


2021 ◽  
Vol 13 (5) ◽  
pp. 168781402110208
Author(s):  
Yuan Zhang ◽  
Lifeng Wang ◽  
Yaodong Zhang ◽  
Yongde Zhang

The thermal deformation of high-speed motorized spindle will affect its reliability, so fully considering its thermal characteristics is the premise of optimal design. In order to study the thermal characteristics of high-speed motorized spindles, a coupled model of thermal-flow-structure was established. Through experiment and simulation, the thermal characteristics of spiral cooling motorized spindle are studied, and the U-shaped cooled motorized spindle is designed and optimized. The simulation results show that when the diameter of the cooling channel is 7 mm, the temperature of the spiral cooling system is lower than that of the U-shaped cooling system, but the radial thermal deformation is greater than that of the U-shaped cooling system. As the increase of the channel diameter of U-shaped cooling system, the temperature and radial thermal deformation decrease. When the diameter is 10 mm, the temperature and radial thermal deformation are lower than the spiral cooling system. And as the flow rate increases, the temperature and radial thermal deformation gradually decrease, which provides a basis for a reasonable choice of water flow rate. The maximum error between experiment and simulation is 2°C, and the error is small, which verifies the accuracy and lays the foundation for future research.