Novel Evaporator Geometries Based on Entrance-Length Flow-Paths for Geothermal Binary Power Plants

Author(s):  
Adrian S. Sabau ◽  
Ali H. Nejad ◽  
James W. Klett ◽  
Adrian Bejan ◽  
Kivanc Ekici

In this paper, a novel geometry is proposed for evaporators that are used in Organic Rankine Cycles. The proposed geometry consists of employing successive plenums at several length-scale levels, creating a multi-scale heat exchanger. The channels at the lowest length-scale levels were considered to have their length given by the thermal entrance-length. Numerical simulations based on turbulent flow correlations for supercritical R134a and water were used to obtain performance indicators for new heat exchangers and baseline heat exchangers. The relationship between the size of the channels at one level, k, with respect to the size of the channels at the next level, k + 1, is based on generalization of the “Murray’s law.” In order to account for the variation of the temperature and heat transfer coefficient in the entrance region, a heat transfer model was developed. The variation of the brine and refrigerant temperatures along each pipe was considered. Using the data on pumping power and weight of metal structures, including that of all the plenums and piping, the total present cost was evaluated using a cost model for shell-and-tube heat exchangers. In addition to the total present cost, the data on overall thermal resistance is also used in identifying optimal heat exchanger configurations. The main design variables include: tube arrangement, number of channels fed from plenum, and number of rows in the tube bank seen by the outside fluid. In order to assess the potential improvement of the new evaporator designs, baseline evaporators were designed. The baseline evaporator designs include long tubes of the same diameter as those of the lowest length-scale levels, placed between one inlet and one outlet. The baseline evaporator designs were created from the new evaporator designs by simply removing most of the internal plenums employing tubes much longer than their entrance length, as they would currently be used. Consistent with geothermal applications, the performance of new heat exchanger designs was compared to that of baseline heat exchanger designs at the same flow rates. For some operating conditions it was found that the new heat exchangers outperform their corresponding baseline heat exchangers.

Entropy ◽  
2019 ◽  
Vol 21 (12) ◽  
pp. 1143 ◽  
Author(s):  
Kevin Fontaine ◽  
Takeshi Yasunaga ◽  
Yasuyuki Ikegami

Ocean thermal energy conversion (OTEC) uses the natural thermal gradient in the sea. It has been investigated to make it competitive with conventional power plants, as it has huge potential and can produce energy steadily throughout the year. This has been done mostly by focusing on improving cycle performances or central elements of OTEC, such as heat exchangers. It is difficult to choose a suitable heat exchanger for OTEC with the separate evaluations of the heat transfer coefficient and pressure drop that are usually found in the literature. Accordingly, this paper presents a method to evaluate heat exchangers for OTEC. On the basis of finite-time thermodynamics, the maximum net power output for different heat exchangers using both heat transfer performance and pressure drop was assessed and compared. This method was successfully applied to three heat exchangers. The most suitable heat exchanger was found to lead to a maximum net power output 158% higher than the output of the least suitable heat exchanger. For a difference of 3.7% in the net power output, a difference of 22% in the Reynolds numbers was found. Therefore, those numbers also play a significant role in the choice of heat exchangers as they affect the pumping power required for seawater flowing. A sensitivity analysis showed that seawater temperature does not affect the choice of heat exchangers, even though the net power output was found to decrease by up to 10% with every temperature difference drop of 1 °C.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1762 ◽  
Author(s):  
Zhe Wang ◽  
Fenghui Han ◽  
Yulong Ji ◽  
Wenhua Li

A marine seawater source heat pump is based on the relatively stable temperature of seawater, and uses it as the system’s cold and heat source to provide the ship with the necessary cold and heat energy. This technology is one of the important solutions to reduce ship energy consumption. Therefore, in this paper, the heat exchanger in the CO2 heat pump system with graphene nano-fluid refrigerant is experimentally studied, and the influence of related factors on its heat transfer enhancement performance is analyzed. First, the paper describes the transformation of the heat pump system experimental bench, the preparation of six different mass concentrations (0~1 wt.%) of graphene nanofluid and its thermophysical properties. Secondly, this paper defines graphene nanofluids as beneficiary fluids, the heat exchanger gains cold fluid heat exergy increase, and the consumption of hot fluid heat is heat exergy decrease. Based on the heat transfer efficiency and exergy efficiency of the heat exchanger, an exergy transfer model was established for a seawater source of tube heat exchanger. Finally, the article carried out a test of enhanced heat transfer of heat exchangers with different concentrations of graphene nanofluid refrigerants under simulated seawater constant temperature conditions and analyzed the test results using energy and an exergy transfer model. The results show that the enhanced heat transfer effect brought by the low concentration (0~0.1 wt.%) of graphene nanofluid is greater than the effect of its viscosity on the performance and has a good exergy transfer effectiveness. When the concentration of graphene nanofluid is too high, the resistance caused by the increase in viscosity will exceed the enhanced heat transfer gain brought by the nanofluid, which results in a significant decrease in the exergy transfer effectiveness.


Author(s):  
M. Izadi ◽  
D. K. Aidun ◽  
P. Marzocca ◽  
H. Lee

The effect of geometrical features on the air-side heat transfer and friction characteristics of an industrial plain fin-and-tube heat exchanger is investigated by 3-D numerical modeling and simulations. The heat exchanger has been designed and employed as an intercooler in a gas power plant and is a large-size compact heat exchanger. Most of the available design correlations developed so far for plain fin–and–tube heat exchangers have been prepared for small-size exchangers and none of them fits completely to the current heat exchanger regarding the geometrical limitations of correlations. It is shown that neglecting these limitations and applying improper correlations may generate considerable amount of error in the design of such a large-size heat exchanger. The geometry required for numerical modeling is produced by Gambit® software and the boundary conditions are defined regarding the real operating conditions. Then, three-dimensional simulations based on the SIMPLE algorithm in laminar flow regime are performed by FLUENT™ code. The effect of fin pitch, tube pitch, and tube diameter on the thermo-hydraulic behavior of the heat exchanger is studied. Some variations in the design of the heat exchanger are suggested for optimization purposes. It is finally concluded that the current numerical model is a powerful tool to design and optimize of large-size plain fin-and-tube heat exchangers with acceptable accuracy.


2021 ◽  
Vol 945 (1) ◽  
pp. 012058
Author(s):  
Sayshar Ram Nair ◽  
Cheen Sean Oon ◽  
Ming Kwang Tan ◽  
S.N. Kazi

Abstract Heat exchangers are important equipment with various industrial applications such as power plants, HVAC industry and chemical industries. Various fluids that are used as working fluid in the heat exchangers such as water, oil, and ethylene glycol. Researchers have conducted various studies and investigations to improve the heat exchanger be it from material or heat transfer point of view. There have been attempts to create mixtures with solid particles suspended. This invention had some drawbacks since the pressure drop was compromised, on top of the occurrence of sedimentation or even erosion, which incurs higher maintenance costs. A new class of colloidal suspension fluid that met the demands and characteristics of a heat exchanger was then created. This novel colloidal suspension mixture was then and now addressed as “nanofluid”. In this study, the usage of functionalized graphene nanoplatelet (GNP) nanofluids will be studied for its thermal conductivity within an annular conduit with angled fins, which encourage swirling flows. The simulation results for the chosen GNP nanofluid concentrations have shown an enhancement in thermal conductivity and heat transfer coefficient compared to the corresponding base fluid thermal properties. The data from this research is useful in industrial applications which involve heat exchangers with finned tubes.


Author(s):  
Kyeong Mo Hwang ◽  
Tae Eun Jin

As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2737
Author(s):  
Francesca Ceglia ◽  
Adriano Macaluso ◽  
Elisa Marrasso ◽  
Maurizio Sasso ◽  
Laura Vanoli

Improvements in using geothermal sources can be attained through the installation of power plants taking advantage of low and medium enthalpy available in poorly exploited geothermal sites. Geothermal fluids at medium and low temperature could be considered to feed binary cycle power plants using organic fluids for electricity “production” or in cogeneration configuration. The improvement in the use of geothermal aquifers at low-medium enthalpy in small deep sites favours the reduction of drilling well costs, and in addition, it allows the exploitation of local resources in the energy districts. The heat exchanger evaporator enables the thermal heat exchange between the working fluid (which is commonly an organic fluid for an Organic Rankine Cycle) and the geothermal fluid (supplied by the aquifer). Thus, it has to be realised taking into account the thermodynamic proprieties and chemical composition of the geothermal field. The geothermal fluid is typically very aggressive, and it leads to the corrosion of steel traditionally used in the heat exchangers. This paper analyses the possibility of using plastic material in the constructions of the evaporator installed in an Organic Rankine Cycle plant in order to overcome the problems of corrosion and the increase of heat exchanger thermal resistance due to the fouling effect. A comparison among heat exchangers made of commonly used materials, such as carbon, steel, and titanium, with alternative polymeric materials has been carried out. This analysis has been built in a mathematical approach using the correlation referred to in the literature about heat transfer in single-phase and two-phase fluids in a tube and/or in the shell side. The outcomes provide the heat transfer area for the shell and tube heat exchanger with a fixed thermal power size. The results have demonstrated that the plastic evaporator shows an increase of 47.0% of the heat transfer area but an economic installation cost saving of 48.0% over the titanium evaporator.


2019 ◽  
Vol 70 (6) ◽  
pp. 2040-2043
Author(s):  
Sinziana Radulescu ◽  
Loredana Irena Negoita ◽  
Ion Onutu

A relation for calculation of the effective overall heat transfer coefficient in a triple concentric-tube heat exchanger is proposed. The relation of the effective overall heat transfer coefficient is obtained based on total thermal resistance and it is applied within a case study for thermal analysis of two triple concentric-tube heat exchangers with different geometries, hot fluids and operating conditions. Through case study it is found that the values of effective overall heat transfer coefficient can be obtained with acceptable errors, up to 3 % for both heat exchangers.


Author(s):  
Amjad Farah ◽  
Krysten King ◽  
Sahil Gupta ◽  
Sarah Mokry ◽  
Wargha Peiman ◽  
...  

This paper presents an extensive study of heat-transfer correlations applicable to supercritical-water flow in vertical bare tubes. A comprehensive dataset was collected from 33 papers by 27 authors, including more than 125 graphs and wide ranges of parameters. The parameters ranges were as follows: pressures 22.5–34.5 MPa, inlet temperatures 85–350°C, mass fluxes 250–3400 kg/m2s, heat fluxes 75–5,400 kW/m2), tube heated lengths 0.6–27.4 m, and tube inside diameters 2–36 mm. This combined dataset was then investigated and analyzed. Heat Transfer Coefficients (HTCs) and wall temperatures were calculated using various existing correlations and compared to the corresponding experimental results. Three correlations were used in this comparison: Bishop et al., Mokry et al. and modified Swenson et al. The main objective of this study was to select the best supercritical-water bare-tube correlation for HTC calculations in: 1) fuel bundles of SuperCritical Water-cooled Reactors (SCWRs) as a preliminary and conservative approach; 2) heat exchangers in case of indirect-cycle SCW Nuclear Power Plants (NPPs); and 3) heat exchangers in case of hydrogen co-generation at SCW NPPs from SCW side. From the beginning, all these three correlations were compared to the Kirillov et al. vertical bare-tube dataset. However, this dataset has a limited range of operating conditions in terms of a pressure (only one pressure value of 24 MPa) and one inside diameter (only 10 mm). Therefore, these correlations were compared with other datasets, which have a much wider range of operating conditions. The comparison showed that in most cases, the Bishop et al. correlation deviates significantly from the experimental data within the pseudocritical region and actually, underestimates the temperature at most times. On the other hand, the Mokry et al. and modified Swenson et al. correlations showed a relatively better fit within the most operating conditions. In general, the modified Swenson et al. correlation showed slightly better fit with the experimental data than other two correlations.


1997 ◽  
Vol 119 (3) ◽  
pp. 193-200 ◽  
Author(s):  
S. D. Dahl ◽  
J. H. Davidson

Determining the performance of indirect solar heating systems that use thermosyphon heat exchangers requires knowledge of how thermosyphon flow rate and heat exchanger performance vary with operating conditions. In this paper, measured performance of a two-pass, tube-in-shell, double-wall heat exchanger is discussed in terms of modeling issues. Thermosyphon heat exchangers may operate in the developing, mixed convection regime where natural convection effects can significantly influence overall heat transfer and friction coefficients. Existing models which assume the thermal and hydraulic behaviors of thermosyphon heat exchangers are only functions of the thermosyphon and collector flow rates may not be suitable for all heat exchanger types. For example, the overall heat-transfer coefficient-area product for the two-pass, tube-in-shell heat exchanger is best expressed as a function of Reynolds, Grashof, and Prandtl numbers on the thermosyphon side of the heat exchanger. It is proposed that annual simulations of solar water heaters with thermosyphon heat exchangers use this type of relationship to characterize heat transfer in the heat exchanger.


2011 ◽  
Vol 133 (11) ◽  
Author(s):  
Feng Zhou ◽  
Nicholas E. Hansen ◽  
David J. Geb ◽  
Ivan Catton

Modeling a fin-and-tube heat exchanger as porous media based on volume averaging theory (VAT), specific geometry can be accounted for in such a way that the details of the original structure can be replaced by their averaged counterparts, and the VAT based governing equations can be solved for a wide range of heat exchanger designs. To complete the VAT based model, proper closure is needed, which is related to a local friction factor and a heat transfer coefficient of a representative elementary volume. The present paper describes an effort to model a fin-and-tube heat exchanger based on VAT and obtain closure for the model. Experiment data and correlations for the air side characteristics of fin-and-tube heat exchangers from the published literature were collected and rescaled using the “porous media” length scale suggested by VAT. The results were surprisingly good, collapsing all the data onto a single curve for friction factor and Nusselt number, respectively. It was shown that using the porous media length scale is very beneficial in collapsing complex data yielding simple heat transfer and friction factor correlations and that by proper scaling, closure is a function of the porous media, which further generalizes macroscale porous media equations. The current work is a step closer to our final goal, which is to develop a universal fast running computational tool for multiple-parameter optimization of heat exchangers.


Sign in / Sign up

Export Citation Format