Shellside Vacuum Condensation With a Noncondensable Gas

Author(s):  
Susan N. Ritchey

Shell-and-tube vacuum condensers are present in many industrial applications such as chemical manufacturing, distillation, and power production [1–3]. They are often used because operating a condenser under vacuum pressures can increase the efficiency of energy conversion, which increases the overall plant efficiency and saves money. Typical operating pressures in the petrochemical industry span a wide range of values, from one atmosphere (101.3 kPa) down to a medium vacuum (1 kPa). The current shellside condensation methods used to predict heat transfer coefficients are based on data collected near or above atmospheric pressure, and the available literature on shellside vacuum condensation generally lacks experimental data. The accuracy of these methods in vacuum conditions well below atmospheric pressure has yet to be validated. Recently, HTRI designed and constructed the Low Pressure Condensation Unit (LPCU) with a rectangular shellside test condenser. To date, heat transfer data have been collected in the LPCU for shellside condensation of a pure hydrocarbon and of a hydrocarbon with noncondensable gas at vacuum pressures ranging from 2.8 to 45 kPa (21 to 338 Torr). Traditional condensation literature methods underpredict the overall heat transfer coefficient by 20.8% ± 20.4% for the pure condensing fluid; whereas they overpredict heat transfer by 36.8% ± 40.0% with the addition of the noncondensable gas. Over or under predicting the overall heat transfer coefficient in the presence of noncondensable gases leads to inefficient condenser designs and the inability to achieve desired process conditions. With the addition of the noncondensable gas, the measured heat exchanger duty was significantly reduced compared to the pure fluid, even at inlet mole fractions below 5%. In one case, a noncondensable inlet mole fraction of 0.63% was estimated to reduce the duty by approximately 10%. Analysis of the acquired high-speed videos shows that the film thickness changes significantly from the top row to the bottom. The videos also display condensate drainage patterns and droplet interactions. The ripples and splashing of the condensate observed in the videos indicates that the Nusselt idealized model is not appropriate for analysis of a real condenser. This article presents the collected heat transfer data and high-speed images of shellside vacuum condensation flow patterns.

2019 ◽  
Vol 111 ◽  
pp. 01001
Author(s):  
Hansol Lim ◽  
Hye-Jin Cho ◽  
Seong-Yong Cheon ◽  
Soo-Jin Lee ◽  
Jae-Weon Jeong

A phase change material based radiant cooling panel with thermoelectric module (PCM-TERCP) is proposed in this study. It consists of two aluminium panels, and phase change materials (PCMs) sandwiched between the two panels. Thermoelectric modules (TEMs) are attached to one of the aluminium panels, and heat sinks are attached to the top side of TEMs. PCM-TERCP is a thermal energy storage concept equipment, in which TEMs freeze the PCM during the night whose melting temperature is 16○C. Therefore, the radiant cooling panel can maintain a surface temperature of 16◦C without the operation of TEM during the day. Furthermore, it is necessary to design the PCM-TERCP in a way that it can maintain the panel surface temperature during the targeted operating time. Therefore, the numerical model was developed using finite difference method to evaluate the thermal behaviour of PCM-TERCP. Experiments were also conducted to validate the performance of the developed model. Using the developed model, the possible operation time was investigated to determine the overall heat transfer coefficient required between radiant cooling panel and TEM. Consequently, the results showed that a overall heat transfer coefficient of 394 W/m2K is required to maintain the surface temperature between 16○C to 18○C for a 3 hours operation.


2009 ◽  
Vol 62-64 ◽  
pp. 694-699 ◽  
Author(s):  
E. Akpabio ◽  
I.O. Oboh ◽  
E.O. Aluyor

Shell and tube heat exchangers in their various construction modifications are probably the most widespread and commonly used basic heat exchanger configuration in the process industries. There are many modifications of the basic configuration which can be used to solve special problems. Baffles serve two functions: Most importantly, they support the tubes in the proper position during assembly and operation and prevent vibration of the tubes caused by flow-induced eddies, and secondly, they guide the shell-side flow back and forth across the tube field, increasing the velocity and the heat transfer coefficient. The objective of this paper is to find the baffle spacing at fixed baffle cut that will give us the optimal values for the overall heat transfer coefficient. To do this Microsoft Excel 2003 package was employed. The results obtained from previous studies showed that to obtain optimal values for the overall heat transfer coefficient for the shell and tube heat exchangers a baffle cut of 20 to 25 percent of the diameter is common and the maximum spacing depends on how much support the tubes need. This was used to validate the results obtained from this study.


2014 ◽  
Vol 592-594 ◽  
pp. 922-926 ◽  
Author(s):  
Devasenan Madhesh ◽  
S. Kalaiselvam

Analysis of heat transfer behaviour of hybrid nanofluid (HyNF) flow through the tubular heat exchanger was experimentally investigated. In this analysis the effects of thermal characteristics of forced convection, Nusselt number, Peclet number, and overall heat transfer coefficient were investigated.The nanofluid was prepared by dispersing the copper-titania hybrid nanocomposite (HyNC) in the water. The experiments were performed for various nanoparticle volume concentrations addition in the base fluid from the range of 0.1% to 1.0%. The experimental results show that the overall heat transfer coefficient was found to increases maximum by 30.4%, up to 0.7% volume concentration of HyNC.


Author(s):  
Ankit Kalani ◽  
Satish G. Kandlikar

Flow boiling in microchannels offers many advantages such as high heat transfer coefficient, higher surface area to volume ratio, low coolant inventory, uniform temperature control and compact design. The application of these flow boiling systems has been severely limited due to early critical heat flux (CHF) and flow instability. Recently, a number of studies have focused on variable flow cross-sectional area to augment the thermal performance of microchannels. In a previous work, the open microchannel with manifold (OMM) configuration was experimentally investigated to provide high heat transfer coefficient coupled with high CHF and low pressure drop. In the current work, high speed images of plain surface using tapered manifold are obtained to gain an insight into the nucleating bubble behavior. The mechanism of bubble nucleation, growth and departure are described through high speed images. Formation of dry spots for both tapered and uniform manifold geometry is also discussed.


2000 ◽  
Author(s):  
G. Hetsroni ◽  
M. Gurevich ◽  
A. Mosyak ◽  
R. Rozenblit ◽  
L. P. Yarin

Abstract During subcooled boiling of pure water and water with cationic surfactants, the motion of bubbles and the temperature of the heated surface were recorded by both a high-speed video camera and an infrared radiometer. The results show that the bubble behavior and the heat transfer mechanism for the surfactant are quite different from those of clear water. Bubbles formed in Habon G solutions were much smaller man those in water and the surface was covered with them faster. Boiling hysteresis is found for degraded solutions. Dependencies of heat transfer coefficient for various solutions were obtained and compared. The boiling curves of surfactant are quite different from the boiling curve of pure water. Experimental results demonstrate that the heat transfer coefficient of the boiling process can be enhanced considerably by the addition of a small amount of Habon G. The experiments show that the limitations of the ER technique with respect to frequency response are outweighed by its unique capacity to measure wall temperature distribution with high spatial resolution over an area encompassing many nucleation sites and over long periods.


Sign in / Sign up

Export Citation Format

Share Document