Evaluation of an Extended-Duct Air Delivery System in Tall Spaces Conditioned by Rooftop Units

2016 ◽  
Author(s):  
Ryan Kennett ◽  
Yunho Hwang ◽  
Reinhard Radermacher

Mixing ventilation in high bay buildings conditioned by rooftop units involves supplying and returning air near the ceiling. Several problems occur in tall spaces, such as higher return air temperatures in the summer and excessive stratification in the winter. A novel air delivery strategy is investigated that involves supplying and returning air at different heights depending on the season. In the summer, air is supplied low and returned just above the occupied zone in order to cool the occupied zone directly, letting the upper zone stratify. In the winter, air is supplied high and returned low in order to draw warm air down from the ceiling, thus promoting destratification. This system’s performance was investigated in a full-scale experiment using measured temperature profiles and utility bills. A calibrated EnergyPlus model used measured temperature profiles as an input to a room-air model to study the effects of stratification on building energy consumption. The EnergyPlus model predicts 19% yearly HVAC electricity savings when considering the additional pressure drop of extended ducting and 37% yearly HVAC electricity savings without considering extra pressure drop. A utility bill analysis of the test facility shows a yearly 28.8% reduction in HVAC electricity consumption.

Kerntechnik ◽  
2018 ◽  
Vol 83 (3) ◽  
pp. 178-180
Author(s):  
P. Ju ◽  
B. Long ◽  
L. Li ◽  
Q. Su ◽  
X. Wu ◽  
...  

1993 ◽  
Vol 17 (2) ◽  
pp. 145-160
Author(s):  
P.H. Oosthuizen ◽  
A. Sheriff

Indirect passive solar crop dryers have the potential to considerably reduce the losses that presently occur during drying of some crops in many parts of the “developing” world. The performance so far achieved with such dryers has, however, not proved to be very satisfactory. If this performance is to be improved it is necessary to have an accurate computer model of such dryers to assist in their design. An important element is any dryer model is an accurate equation for the convective heat transfer in the collector. To assist in the development of such an equation, an experimental and numerical study of the collector heat transfer has been undertaken. In the experimental study, the collector was simulated by a 1m long by 1m wide channel with a gap of 4 cm between the upper and lower surfaces. The lower surface of the channel consisted of an aluminium plate with an electrical heating element, simulating the solar heating, bonded to its lower surface. Air was blown through this channel at a measured rate and the temperature profiles at various points along the channel were measured using a shielded thermocouple probe. Local heat transfer rates were then determined from these measured temperature profiles. In the numerical study, the parabolic forms of the governing equations were solved by a forward-marching finite difference procedure.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 510
Author(s):  
Lukas Boehler ◽  
Mateusz Daniol ◽  
Ryszard Sroka ◽  
Dominik Osinski ◽  
Anton Keller

Surgical procedures involve major risks, as pathogens can enter the body unhindered. To prevent this, most surgical instruments and implants are sterilized. However, ensuring that this process is carried out safely and according to the normative requirements is not a trivial task. This study aims to develop a sensor system that can automatically detect successful steam sterilization on the basis of the measured temperature profiles. This can be achieved only when the relationship between the temperature on the surface of the tool and the temperature at the measurement point inside the tool is known. To find this relationship, the thermodynamic model of the system has been developed. Simulated results of thermal simulations were compared with the acquired temperature profiles to verify the correctness of the model. Simulated temperature profiles are in accordance with the measured temperature profiles, thus the developed model can be used in the process of further development of the system as well as for the development of algorithms for automated evaluation of the sterilization process. Although the developed sensor system proved that the detection of sterilization cycles can be automated, further studies that address the possibility of optimization of the system in terms of geometrical dimensions, used materials, and processing algorithms will be of significant importance for the potential commercialization of the presented solution.


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4046 ◽  
Author(s):  
Sooyoun Cho ◽  
Jeehang Lee ◽  
Jumi Baek ◽  
Gi-Seok Kim ◽  
Seung-Bok Leigh

Although the latest energy-efficient buildings use a large number of sensors and measuring instruments to predict consumption more accurately, it is generally not possible to identify which data are the most valuable or key for analysis among the tens of thousands of data points. This study selected the electric energy as a subset of total building energy consumption because it accounts for more than 65% of the total building energy consumption, and identified the variables that contribute to electric energy use. However, this study aimed to confirm data from a building using clustering in machine learning, instead of a calculation method from engineering simulation, to examine the variables that were identified and determine whether these variables had a strong correlation with energy consumption. Three different methods confirmed that the major variables related to electric energy consumption were significant. This research has significance because it was able to identify the factors in electric energy, accounting for more than half of the total building energy consumption, that had a major effect on energy consumption and revealed that these key variables alone, not the default values of many different items in simulation analysis, can ensure the reliable prediction of energy consumption.


1992 ◽  
Vol 114 (1) ◽  
pp. 46-54 ◽  
Author(s):  
P. J. Vermeulen ◽  
P. Grabinski ◽  
V. Ramesh

The mixing of an acoustically pulsed air jet with a confined hot crossflow has been assessed by temperature profile measurements. These novel experiments were designed to examine the effects of acoustic driver power and Strouhal number on jet structure, penetration, and mixing. The results showed that excitation produced strong changes in the measured temperature profiles. This resulted in significant increases in mixing zone size, penetration (at least 100 percent increase), and mixing, and the length to achieve a given mixed state was shortened by at least 70 percent. There was strong modification to the jet-wake region. The increase in jet penetration and mixing was saturating near 90 W, the largest driving power tested. The jet response as determined by penetration and mixing was optimum at a Strouhal number of 0.27. Overall, pulsating the jet flow significantly improved the jet mixing processes in a controllable manner.


2021 ◽  
Author(s):  
Simon Schüppler ◽  
Roman Zorn ◽  
Hagen Steger ◽  
Philipp Blum

<p>The measurement of the undisturbed ground temperature (UGT) serves to design low-temperature geothermal systems, in particular borehole heat exchangers (BHEs), and to monitor shallow aquifers. Wireless and miniaturized probes such as the Geosniff (GS) measurement sphere, which are characterized by an autarkic energy supply and equipped with pressure and temperature sensors, are increasingly being used for the measurement of highly resolved vertical temperature profiles. The measurement probe sinks along the course of the BHE with a selectable measurement frequency to the bottom of the BHE and is useable for initial measurements as well as long term groundwater monitoring. To ensure quality assurance and further improvement of this emerging technology, the analysis of measurement errors and uncertainties of wireless temperature measurements (WTMs) is indispensable. Thus, we provide an empirical laboratory analysis of random, systematic, and dynamic measurement errors, which lead to the measurement uncertainty of WTMs using the GS as a representative device. We subsequently transfer the analysed uncertainty to measured vertical temperature profiles of the undisturbed ground at a BHE site in Karlsruhe, Germany. The precision and accuracy of 0.011 K and -0.11 K, respectively, ensure a high reliability of the GS measurements. The largest measurement uncertainty is obtained within the first five meters of descent resulting from the thermal time constant τ of 4 s. The measured temperature profiles are qualitatively compared with common Distributed Temperature Sensing (DTS) using fiber optic cables and punctual Pt-100 sensors. Wireless probes are also suitable to correct temperature profiles recorded with fiber optics with systematic errors of up to -0.93 K. Various boundary conditions such as the inclination of the BHE pipes or changes of the viscosity and density of the BHE fluid effect the descent rate of the GS of up to 40 %. We additionally provide recommendations for technical implementations of future measurement probes and contribute to an improved understanding and further development of WTMs.</p>


Author(s):  
Ulf R. Rådeklint ◽  
Christer S. Hjalmarsson

A high pressure hot test facility for cooled gas turbine components has been developed for use in turbine cooling research. In this facility, heat transfer tests for a sector of real turbine vanes can be performed under continuous operation. The heat transfer tests are performed at an operating point that is scaled down from the real engine operating point. The compressor can deliver air at the rate of up to 10 kg/s at 20 bars. Air temperatures of up to 1170 K can be achieved by using an oil-fired combustor. Besides conventional instrumentation such as thermocouples and pressure probes, the facility is equipped with an IR-camera to map two-dimensional wall temperature fields. Hot wire anemometry and an LDV system are used to determine mean and fluctuating velocity components. This paper describes design and performance of the test facility as well as the control and measurement equipment. The test and evaluation procedures used for testing of cooled gas turbine vanes are also presented.