scholarly journals Evaluation of U10Mo Fuel Plate Irradiation Behavior via Numerical and Experimental Benchmarking

Author(s):  
Samuel J. Miller ◽  
Hakan Ozaltun

This article analyzes dimensional changes due to irradiation of monolithic plate-type nuclear fuel and compares results with finite element analysis of the plates during fabrication and irradiation. Monolithic fuel plates tested in the Advanced Test Reactor (ATR) at Idaho National Lab (INL) are being used to benchmark the performance of proposed fuel for several high power research reactors. Post-irradiation metallographic images of plates sectioned at the mid-plane were analyzed to determine dimensional changes of the fuel and the cladding response. A constitutive model of the fabrication process and irradiation behavior of the tested plates was developed using the general purpose commercial finite element analysis package, ABAQUS. Using calculated burn-up profiles of irradiated plates to model the power distribution and including irradiation behaviors such as swelling and irradiation enhanced creep, model simulations allow analysis of plate parameters that are either impossible or infeasible in an experimental setting. The development and progression of fabrication induced stress concentrations at the plate edges was of primary interest, as these locations have a unique stress profile during irradiation. Additionally, comparison between 2D and 3D models was performed to optimize analysis methodology. In particular, the ability of 2D and 3D models to account for out of plane stresses which result in 3-dimensional creep behavior that is a product of these components. Results show that assumptions made in 2D models for the out-of-plane stresses and strains cannot capture the 3-dimensional physics accurately and thus 2D approximations are not representative. Stress-strain fields are dependent on plate geometry and irradiation conditions, thus, if stress based criteria is used to predict plate behavior (as opposed to material impurities, fine micro-structural defects, or sharp power gradients), unique 3D finite element formulation for each plate is required.

2006 ◽  
Vol 15 (1) ◽  
pp. 096369350601500
Author(s):  
Dionisios T. G. Katerelos

Among the principal damage modes in composite laminates, is delamination. Design details, such as free, straight or curved, edges, induce large local out-of-plane loads, generating interlaminar stresses. In the present work, the effect of ply thickness and the angle between two adjacent layers on the interlaminar stresses developed at the vicinity of straight and curved free edges in composite laminates under thermomechanical loading is examined. The results are obtained by the application of a 3-dimensional Finite Element Analysis.


1999 ◽  
Vol 122 (1) ◽  
pp. 22-26 ◽  
Author(s):  
M. Law ◽  
W. Payten ◽  
K. Snowden

Modeling of welded joints under creep conditions with finite element analysis was undertaken using the theta projection method. The results were compared to modeling based on a simple Norton law. Theta projection data extends the accuracy and predictive capability of finite element modeling of critical structures operating at high temperature and pressure. In some cases analyzed, it was found that the results diverged from those gained using a Norton law creep model. [S0094-9930(00)00601-6]


2007 ◽  
Vol 23 ◽  
pp. 229-232
Author(s):  
Liliana Sandu ◽  
Nicolae Faur ◽  
Cristina Bortun ◽  
Sorin Porojan

Several studies evaluated the removable partial dentures by the finite element analysis, but none of them evaluated thermal stresses. The purpose of the study was to explore the influence of thermal oral changes induced by hot/cold liquids and food on the circumferential cast clasps of removable partial dentures. A 3-dimensional finite element method was used to explore the temperature distribution, thermal stress and the influence of thermal changes on stresses and displacements of circumferential clasps during functions. Thermal variations induce stresses in dental clasps, high temperatures having a more aggressive effect than lower one. Cold liquids and food induce high stresses in the retentive clasp arms while hot ones in the occlusal rests of the clasps and for the back action clasp also in the minor connector. The study suggests the importance of consFigureidering thermal variations for stress analyses of the cast clasps.


2003 ◽  
Vol 15 (02) ◽  
pp. 82-85 ◽  
Author(s):  
SHYH-CHOUR HUANG ◽  
CHANG-FENG TSAI

This paper presents results from using a 3-dimensional finite element model to assess the stress distribution in the bone, in the implant and in the abutment as a function of the implant's diameter and length. Increasing implant diameter and length increases the stability of the implant system. By using a finite element analysis, we show that implant length does not decrease the stress distribution of either the implant or the bone. Alternatively, however implant diameter increases reduce the stresses. For the latter case, the contact area between implant and bone is increased thus the stress concentration effect is decreased. Also, with increased implant diameter the bone loss is decreased and as a consequence the success rate is improved.