Effect of Tree Shading on the Thermal Load of a House in a Warm Climate Zone in Mexico

Author(s):  
M. A. Chagolla ◽  
G. Alvarez ◽  
E. Simá ◽  
R. Tovar ◽  
G. Huelsz

This paper presents the effect of the shade of a tree on the indoor temperature and thermal loads of a house (test house) located in the State of Morelos, Mexico, 18° 50′ 43″ north latitude and 99° 10′ 44″ west longitude. Energy Plus was used to simulate different geometries of the shadow of a tree and the simulation results were compared with experimental measurements of the house without air-conditioning, for one warm and one cold week of the year 2011. The results showed that the maximum temperature difference between the measured and simulated temperatures with both geometry models of tree-shading was 1.7°C. When the effect of tree shading is not considered, it was found that there is a maximum temperature increase of 4°C in the warm week compared with the measured results. In the cold week, the temperature increase was 1.3°C compared with the measured results. Simulation results for an air-conditioned tree-shaded test house show that total annual energy consumption for cooling and heating to achieve thermal comfort represents a substantial energy savings of 76.6% when compared with an unshaded house.

2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Majo Carrasco-Tenezaca ◽  
Ebrima Jatta ◽  
Musa Jawara ◽  
John Bradley ◽  
Margaret Pinder ◽  
...  

Abstract Background In rural sub-Saharan Africa, thatch roofs are being replaced by metal roofs. Metal roofing, however, increases indoor temperatures above human comfort levels, and thus makes it more likely that residents will not use an insecticide-treated bed net (ITN) at night. Whether the colour of a metal roof affects indoor temperature and human comfort was assessed. Methods Two identical, experimental houses were constructed with metal roofs in rural Gambia. Roof types were: (1) original bare-metal, (2) painted with red oxide primer or (3) white gloss, to reflect solar radiation. Pairwise comparisons were run in six, five-night blocks during the malaria season 2018. Indoor climate was measured in each house and multivariate analysis used to compare indoor temperatures during the day and night. Results From 21.00 to 23.59 h, when most residents decide whether to use an ITN or not, the indoor temperature of a house with a bare metal roof was 31.5 °C (95% CI  31.2–31.8 °C), a red roof, 30.3 °C (95% CI 30.0–30.6) and a white roof, 29.8 °C (95% CI 29.4–30.1). During the same period, red-roofed houses were 1.23 °C cooler (95% CI 1.22–1.23) and white roofs 1.74 °C cooler (95% CI 1.70–1.79) than bare-metal roofed houses (p  < 0.001). Similar results were found from 00.00 to 06.00 h. Maximum daily temperatures were 0.93 °C lower in a white-roofed house (95% CI  0.10–0.30, p  < 0.001), but not a red roof (mean maximum temperature difference  = 0.44 °C warmer, 95% CI  0.43–0.45, p  = 0.081), compared with the bare-metal roofed houses. Human comfort analysis showed that from 21.00 to 23.59 h houses with white roofs (comfortable for 87% time) were more comfortable than bare-metal roofed houses (comfortable for 13% time; odds ratio  = 43.7, 95% CI 27.5–69.5, p  < 0.001). The cost of painting a metal roof white is approximately 31–68 USD. Conclusions Houses with a white roof were consistently cooler and more comfortable than those with a bare metal roof. Painting the roofs of houses white is a cheap way of making a dwelling more comfortable for the occupants and could potentially increase bed net use in hot humid countries.


2021 ◽  
Author(s):  
Majo Carrasco-Tenezaca ◽  
Musa Jawara ◽  
John Bradley ◽  
Margaret Pinder ◽  
Umberto D’Alessandro ◽  
...  

Abstract Background In rural sub-Saharan Africa, thatch roofs are being replaced by metal roofs. Metal roofing, however, increases indoor temperatures above human comfort levels, and thus makes it more likely that residents will not use an insecticide-treated bednet (ITN) at night. We assessed whether the colour of a metal roof affects indoor temperature and human comfort. Methods Two identical, experimental houses were constructed with metal roofs in rural Gambia. Roof types were: (1) original bare-metal, (2) painted with red oxide primer or (3) white gloss, to reflect solar radiation. Pairwise comparisons were run in six, five-night blocks during the malaria season 2018. Indoor climate was measured in each house and multivariate analysis used to compare indoor temperatures during the day and night. Results From 21.00 h to 23.59 h, when most residents decide whether to use an ITN or not, the indoor temperature of a house with a bare metal roof was 31.5 ºC (95%CI = 31.2–31.8 ºC), a red roof, 30.3 ºC (95%CI = 30.0-30.6) and a white roof, 29.8 ºC (95%CI = 29.4–30.1). During the same period, red-roofed houses were 1.23 oC cooler (95%CI = 1.22–1.23) and white roofs 1.74 oC cooler (95%CI = 1.70–1.79) than bare-metal roofed houses (p < 0.001). Similar results were found from 00.00 h to 06.00 h. Maximum daily temperatures were 0.93 oC lower in a white-roofed house (95%CI = 0.10–0.30, p < 0.001), but not a red roof (mean maximum temperature difference = 0.44 oC warmer, 95%CI = 0.43–0.45, p = 0.081), compared with the bare-metal roofed houses. Human comfort analysis showed that from 21.00 h to 23.59 h houses with white roofs (comfortable for 87% time) were more comfortable than bare-metal roofed houses (comfortable for 13% time; odds ratio = 43.7, 95%CI:27.5–69.5, p < 0.001). The cost of painting a metal roof white is approximately 31–68 USD. Conclusions Houses with a white roof were consistently cooler and more comfortable than those with a bare metal roof. Painting the roofs of houses white is a cheap way of making a dwelling more comfortable for the occupants and could potentially increase bed-net use in hot humid countries.


2021 ◽  
Vol 13 (2) ◽  
pp. 323
Author(s):  
Liang Chen ◽  
Xuelei Wang ◽  
Xiaobin Cai ◽  
Chao Yang ◽  
Xiaorong Lu

Rapid urbanization greatly alters land surface vegetation cover and heat distribution, leading to the development of the urban heat island (UHI) effect and seriously affecting the healthy development of cities and the comfort of living. As an indicator of urban health and livability, monitoring the distribution of land surface temperature (LST) and discovering its main impacting factors are receiving increasing attention in the effort to develop cities more sustainably. In this study, we analyzed the spatial distribution patterns of LST of the city of Wuhan, China, from 2013 to 2019. We detected hot and cold poles in four seasons through clustering and outlier analysis (based on Anselin local Moran’s I) of LST. Furthermore, we introduced the geographical detector model to quantify the impact of six physical and socio-economic factors, including the digital elevation model (DEM), index-based built-up index (IBI), modified normalized difference water index (MNDWI), normalized difference vegetation index (NDVI), population, and Gross Domestic Product (GDP) on the LST distribution of Wuhan. Finally, to identify the influence of land cover on temperature, the LST of croplands, woodlands, grasslands, and built-up areas was analyzed. The results showed that low temperatures are mainly distributed over water and woodland areas, followed by grasslands; high temperatures are mainly concentrated over built-up areas. The maximum temperature difference between land covers occurs in spring and summer, while this difference can be ignored in winter. MNDWI, IBI, and NDVI are the key driving factors of the thermal values change in Wuhan, especially of their interaction. We found that the temperature of water area and urban green space (woodlands and grasslands) tends to be 5.4 °C and 2.6 °C lower than that of built-up areas. Our research results can contribute to the urban planning and urban greening of Wuhan and promote the healthy and sustainable development of the city.


Author(s):  
O.I. MARKOV

Numerical modelling thermal and thermoelectric processes in a branch of solid–state thermoelectric of Peltier cooler is performed, taking into account heat exchange by convection and radiation. The numerical calculation of the branch was carried out in the mode of the maximum temperature difference.


Author(s):  
Jianshu Lin ◽  
Hong Wang

A comprehensive analysis method is proposed to resolve the problem of simulating a complex thermo-flow with two kinds of distinct characteristic length in the dry gas seal, and a conjugated simulation of the complicated heat transfer and the gas film flow is carried out by using the commercial CFD software CFX. By using the proposed method, a three dimensional of velocity and pressure field in the gas film flow and the temperature distribution within the sealing rings are investigated for three kinds of film thickness, respectively. A comparison of thermo-hydrodynamics of the dry gas seals is conducted between the sealed gas of air and helium. The latter one is used in a helium circulator for High Temperature Gas-cooled Reactor (HTGR). From comparisons and discussions of a series of simulation results, it will be found that the comprehensive proposal is effective and simulation results are reasonable, and the maximum temperature rise in the dry gas seal is within the acceptable range of HTGR safety requirements.


2018 ◽  
Vol 7 (3.3) ◽  
pp. 373
Author(s):  
Sun Pil Kwon ◽  
Jae Jun Jung ◽  
Byoung Jo Jung

Background/Objectives: To improve a thermal load by increasing internal thermal effect of a building from direct solar radiation through an increase of glass windows.Methods/Statistical analysis: Through the establishment of test beds of the same size, the data of temperature, humidity, solar insolation and PMV of each test bed with or without external louver are acquired to analyze thermal environmental with the simulation.Findings: For the analysis of thermal environment, the amount of energy consumption has been analyzed through the simulation and the data of temperature, humidity, solar insolation and PMV have been acquired for the analysis. With the simulation, about 20% energy saving has been confirmed and the daily averages of temperature and humidity between 8AM to 7PM have been calculated to calculate the maximum temperature difference to be 9.4℃. The solar insolation between 9AM and 7PM was 300W/m2 or below.Improvements/Applications: The improvement of thermal effect with an external louver has been confirmed. It may be applied to the louver system to improve building thermal environment, awning to control direct solar radiation, blind to improve uniformity of illumination intensity toward building during daytime, external blind and ceiling louver system. 


2021 ◽  
Vol 315 ◽  
pp. 3-9
Author(s):  
Yuan Gao ◽  
Li Hua Zhan ◽  
Hai Long Liao ◽  
Xue Ying Chen ◽  
Ming Hui Huang

The uniformity of temperature field distribution in creep aging process is very important to the forming accuracy of components. In this paper, the temperature field distribution of 2219 aluminum alloy tank cover during aging forming is simulated by using the finite element software FLUENT, and a two-stage heating process is proposed to reduce the temperature field distribution heterogeneity. The results show that the temperature difference of the tank cover is large in the single-stage heating process, and the maximum temperature difference is above 27°C,which seriously affects the forming accuracy of the tank cover. With two-stage heating process, the temperature difference in the first stage has almost no direct impact on the forming accuracy of the top cover. In the second stage, the temperature difference of the tank cover is controlled within 10°C, compared with the single-stage heating, the maximum temperature difference is reduced by more than 17°C. The two-stage heating effectively reduces the heterogeneity of the temperature field of the top cover. The research provides technical support for the precise thermal mechanical coupling of large-scale creep aging forming components.


Sensors ◽  
2019 ◽  
Vol 19 (10) ◽  
pp. 2281 ◽  
Author(s):  
Anne-Katrin Mahlein ◽  
Elias Alisaac ◽  
Ali Al Masri ◽  
Jan Behmann ◽  
Heinz-Wilhelm Dehne ◽  
...  

Optical sensors have shown high capabilities to improve the detection and monitoring of plant disease development. This study was designed to compare the feasibility of different sensors to characterize Fusarium head blight (FHB) caused by Fusarium graminearum and Fusarium culmorum. Under controlled conditions, time-series measurements were performed with infrared thermography (IRT), chlorophyll fluorescence imaging (CFI), and hyperspectral imaging (HSI) starting 3 days after inoculation (dai). IRT allowed the visualization of temperature differences within the infected spikelets beginning 5 dai. At the same time, a disorder of the photosynthetic activity was confirmed by CFI via maximal fluorescence yields of spikelets (Fm) 5 dai. Pigment-specific simple ratio PSSRa and PSSRb derived from HSI allowed discrimination between Fusarium-infected and non-inoculated spikelets 3 dai. This effect on assimilation started earlier and was more pronounced with F. graminearum. Except the maximum temperature difference (MTD), all parameters derived from different sensors were significantly correlated with each other and with disease severity (DS). A support vector machine (SVM) classification of parameters derived from IRT, CFI, or HSI allowed the differentiation between non-inoculated and infected spikelets 3 dai with an accuracy of 78, 56 and 78%, respectively. Combining the IRT-HSI or CFI-HSI parameters improved the accuracy to 89% 30 dai.


Materials ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 5340
Author(s):  
Kamil Jurczyszyn ◽  
Witold Trzeciakowski ◽  
Zdzisław Woźniak ◽  
Piotr Ziółkowski ◽  
Mateusz Trafalski

Background: Lasers are widely used in medicine in soft and hard tissue surgeries and biostimulation. Studies found in literature typically compare the effects of single-wavelength lasers on tissues or cell cultures. In our study, we used a diode laser capable of emitting three components of visible light (640 nm, red; 520 nm, green; 450 nm, blue) and combining them in a single beam. The aim of the study was to assess the effects of laser radiation in the visible spectrum on tissue in vitro, depending on the wavelength and pulse width. Methods: All irradiations were performed using the same output power (1.5 W). We used various duty cycles: 10, 50, 80 and 100% with 100 Hz frequency. Maximum superficial temperature, rate of temperature increase and lesion depth were investigated. Results: Maximum superficial temperature was observed for 450 + 520 nm irradiation (100% duty cycle). The highest rate of increase of temperature was noted for 450 + 520 nm (100% duty cycle). Maximum lesion depth was observed in case of three-wavelength irradiation (450 + 520 + 640 nm) for 100, 80 and 50% duty cycles. Conclusions: The synergistic effect of two-wavelength (450 + 520 nm) irradiation was observed in case of maximum temperature measurement. The deepest depth of lesion was noted after three-wavelength irradiation (450 + 520 + 640 nm).


Sign in / Sign up

Export Citation Format

Share Document