Gas-Liquid Two-Phase Flow Regimes in Microchannels

Author(s):  
M. K. Akbar ◽  
D. A. Plummer ◽  
S. M. Ghiaasiaan

Recent experimental data dealing with gas-liquid two-phase flow regimes and their transitions in microchannels with circular and near-circular cross-sections are reviewed and compared. It is shown that, for microchannels with hydraulic diameters close to 1 mm, the available data are in good agreement. These data are used as the basis for the development of a simple Weber number-based flow regime map that divides the entire flow map into four zones: a surface tension dominated zone including bubbly and plug flow patterns; an inertia dominated zone representing the annular flow regime; a dispersed/churn flow zone; and a transition zone that consists of other intermittent flow patterns. Comparison is als o made with the limited available data representing channels with slightly larger hydraulic diameters or different cross-sectional geometries, and the effects of channel cross-sectional geometry and size are examined and discussed. The areas in need of further systematic experimental investigation are identified.

2000 ◽  
Author(s):  
John W. Coleman ◽  
Srinivas Garimella

Abstract An experimental investigation of two-phase flow mechanisms during condensation of refrigerant R134a in small diameter round and rectangular tubes was conducted. A 4.91 mm round tube, and four round tubes with hydraulic diameters ranging from 1 mm – 4 mm were studied to characterize the influence of tube miniaturization on the flow mechanisms. For each tube under consideration, flow mechanisms were recorded over the entire range of qualities 0 < x < 1, and for five different mass fluxes between 150 kg/m2-s and 750 kg/m2-s. Approximately 50 data points were recorded for each tube to obtain a comprehensive understanding of the effects of geometry, mass flux and quality on the phase-change flow mechanisms. The flow mechanisms were categorized into four different flow regimes: intermittent flow, wavy flow, annular flow, and dispersed flow. In addition, the large amount of data over a wide range of test conditions enabled the delineation of several different flow patterns within each flow regime, which provides a clearer understanding of the different modes of two-phase flow. Transition lines between the respective flow patterns and regimes on these maps were established based on the experimental data. It was found that the intermittent flow regime becomes larger as the tube hydraulic diameter is decreased. Also, the size of the wavy flow regime decreases for the small diameter tubes, and disappears completely for the 1 × 1 mm square tube. These maps and transition lines can be used to predict the flow pattern or regime that will be established for a given mass flux, quality and tube geometry.


2021 ◽  
Author(s):  
Faraj Ben Rajeb ◽  
Syed Imtiaz ◽  
Yan Zhang ◽  
Amer Aborig ◽  
Mohamed M. Awad ◽  
...  

Abstract Slug flow is one of the most common flow patterns in non-Newtonian two-phase flow in pipes. It is a very common occurrence in gas-liquid two-phase flow in the pipe. Usually, it is an unfavorable flow pattern due to its unsteady nature, intermittency as well as high pressure drop. The differences between slug flow and elongated bubble flow are not clear because usually these two types of flow combined under one flow category. In general, these two-phase flow regimes are commonly defined as intermittent flow. In the present study, pressure gradient, and wave behavior in slug flow have been investigated depending on experimental work. In addition, void fraction has been estimated regarding available superficial liquid and gas velocities. The experimental records of superficial velocities of gas and liquid for slug flow and other flow patterns is used to create flow regime map for the gas non-Newtonian flow system. The effect of investigated flow regime velocities for non-Newtonian/gas flow on pressure drop and void fraction is reported. Pressure drop has been discovered to be reduced in slug flow more than other flow patterns due to high shear thinning behavior.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Renato P. Coutinho ◽  
Ligia Tornisiello ◽  
Paulo J. Waltrich

Abstract A limited amount of work exists on gas–liquid flow in vertical pipe annulus, and, to the knowledge of the authors, there is no work on the literature to characterize vertical downward two-phase flow in pipe annulus. In the petroleum industry, downward two-phase in annulus is encountered on liquid-assisted gas-lift (LAGL) unloading and production operations. This study presents experimental data for pressure gradient, liquid holdup, and flow regimes for vertical downward two-phase (air and water) flow in pipe annulus. Also, the applicability of two-phase flow models are evaluated. The experimental results show that the liquid holdup is consistently higher for downward flow in annulus than in pipes for the annular flow regime, and these differences are as high as 45%. When the flow regime map for downward flow in annulus is compared with the ones in the literature for flow in pipes, it is observed that the intermittent flow in pipes occurs at lower liquid velocities than flow in annulus. The comparison between experimental data and model results also shows some discrepancy for liquid holdup and pressure gradient. These differences are high for annular and intermittent flow regimes, with errors of 100% for the liquid holdup and 200% for pressure gradient. However, the errors for bubble flow regime are much smaller, generally lower than 20%.


2011 ◽  
Vol 133 (9) ◽  
Author(s):  
Sidharth Paranjape ◽  
Shao-Wen Chen ◽  
Takashi Hibiki ◽  
Mamoru Ishii

Flow regime maps were obtained for adiabatic air-water two-phase flow through a flow channel with 8 × 8 rod bundle, which simulated a typical rod bundle in a boiling water reactor. Impedance void meters were used to measure the area averaged void fraction at various axial locations in the flow channel. The Cumulative Probability Distribution Functions of the signals from the impedance meters were utilized along with self organizing neural network methodology to identify the flow regimes. The flow regimes were identified at five axial locations in the channel in order to understand the development of the flow regimes in axial direction. The experimental flow regime transition boundaries for bubbly to cap-bubbly and part of the cap-turbulent to churn-turbulent agreed with the theoretical boundaries of bubbly to slug and slug to churn-turbulent in round pipes. In addition, the two impedance void meters located across a spacer grid, revealed the nature of change in the flow regime across the spacer grid.


Author(s):  
Darin J. Sharar ◽  
Arthur E. Bergles ◽  
Nicholas R. Jankowski ◽  
Avram Bar-Cohen

A non-intrusive optical method for two-phase flow pattern identification was developed to validate flow regime maps for two-phase adiabatic flow in a small diameter tube. Empirical measurements of film thickness have been shown to provide objective identification of the dominant two-phase flow regimes, representing a significant improvement over the traditional use of exclusively visual and verbal descriptions. Use of this technique has shown the Taitel-Dukler, Ullmann-Brauner, and Wojtan et al. phenomenological flow regime mapping methodologies to be applicable, with varying accuracy, to small diameter two-phase flow.


Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Wei Wang ◽  
Wei Cheng ◽  
Kai Li ◽  
Chen Lou ◽  
Jing Gong

A systematic work on the prediction of flow patterns transition of the oil-water two-phase flows is carried out under a wide range of oil phase viscosities, where four main flow regimes are considered including stratified, dispersed, core-annular, and intermittent flow. For oil with a relatively low viscosity, VKH criterion is considered for the stability of stratified flow, and critical drop size model is distinguished for the transition of o/w and w/o dispersed flow. For oil with a high viscousity, boundaries of core-annular flow are based on criteria proposed by Bannwart and Strazza et al. and neutral stability law ignoring that the velocity of the viscous phase is introduced for stratified flow. Comparisons between predictions and quantities of available data in both low and high viscosity oil-water flow from literatures show a good agreement. The framework provides extensive information about flow patterns transition of oil-water two-phase flow for industrial application.


Author(s):  
Ahmad Fazeli ◽  
Ali Vatani

Two-phase flow pipelines are utilized in simultaneous transferring of liquid and gas from reservoir fields to production units and refineries. In order to obtain the hydraulic design of pipelines, pressure drop and liquid holdup were calculated following pipeline flow regime determination. Two semi-empirical and mechanistical models were used. Empirical models e.g. Beggs & Brill, 1973, are only applicable in certain situations were pipeline conditions are adaptable to the model; therefore we used the Taitel & Dukler, 1976, Baker et al., 1988, Petalas & Aziz, 1998, and Gomez et al., 1999, mechanistical models which are practical in more extensive conditions. The FLOPAT code was designed and utilized which is capable of the determining the physical properties of the fluid by either compositional or non-compositional (black oil) fluid models. It was challenged in various pipeline positions e. g. horizontal, vertical and inclined. Specification of the flow regime and also pressure drop and liquid holdup could precisely be calculated by mechanistical models. The flow regimes considered in the pipeline were: stratified, wavy & annular (Segregated Flow), plug & slug (Intermittent Flow) and bubble & mist (Distributive Flow). We also compared output results against the Stanford Multiphase Flow Database which were used by Petalas & Aziz, 1998, and the effect of the flow rate, pipeline diameter, inclination, temperature and pressure on the flow regime, liquid holdup and pressure drop were studied. The outputs (flow regime, pressure drop and liquid holdup) were comparable with the existing pipeline data. Moreover, by this comparison one may possibly suggest the more suitable model for usage in a certain pipeline.


2002 ◽  
Vol 124 (2) ◽  
pp. 144-153 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
V. P. Janzen ◽  
T. Whan

The results of a series of tests describing the vibration behavior of several rotated triangular tube bundles subjected to two-phase cross flows are presented. Tube bundles with a pitch-to-diameter ratio of approximately 1.5 were tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, hydrodynamic mass, two-phase damping and local void-fraction were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability leading to lower than expected threshold flow velocities for instability. This effect was more pronounced in Freon two-phase flow than in air-water, and appeared well correlated to the transition between continuous and intermittent flow regimes. Generally, random turbulence excitation forces were much lower in Freon than in air-water. Although very dependent on void fraction, as expected, damping was quite similar in air-water and Freon.


2009 ◽  
Vol 131 (4) ◽  
Author(s):  
M. Kawaji ◽  
K. Mori ◽  
D. Bolintineanu

The effects of gas-liquid inlet geometry and mixing method on adiabatic gas-liquid two-phase flow in a microchannel of 100 μm diameter have been investigated using a T-junction inlet with the same internal diameter as the microchannel. Two-phase flow patterns, void fraction, and friction pressure drop data obtained with the T-junction inlet were found to be significantly different from those obtained previously with a reducer inlet. For the T-junction inlet, the two-phase flow patterns in the microchannel were predominantly intermittent flows with short gas and liquid plugs/slugs flowing with nearly equal velocities. The void fraction data then conformed nearly to that of a homogeneous flow model, and the two-phase friction multiplier data could be described by the Lockhart–Martinelli correlation applicable to larger channels. However, when a reducer inlet was used previously and the diameter of the inlet section was much larger than that of the microchannel, an intermittent flow of long gas slugs separated by long liquid slugs became prevalent and the void fraction decreased to values far below the homogeneous void fraction. The differences in the two-phase flow characteristics between a T-junction inlet and reducer inlet were attributed to the differences in the gas bubble/slug generation mechanisms.