A High Shear Rate Sliding Plate Rheometer for Nonlinear Viscoelasticity

2002 ◽  
Author(s):  
Gholamhossein Sodeifian ◽  
Ali Haghtalab ◽  
Amir Abdollah

In most of polymer processings, such as injection molding and extrusion, materials are subjected to high deformations. In order to study nonlinear viscoelastic properties, it is necessary to have an instrument to generate high shear rates. A new sliding plate rheometer incorporating shear stress transducer has been developed. This rheometer has been equipped with a robust servohydraulic linear actuator which can generate shear rates and frequencies up to 900 (1/S) and 500 (Hz) respectively, compared with maximum 500 (1/S) and 100 (Hz), used in latest researches. Using this system, a wider range of nonlinear viscoelasticity can be investigated.

The Eyring theory of viscous flow suggests that lubricating oils should exhibit shear thinning when the shear stress exceeds about 5 MPa. The results of friction experiments in rolling-contact disc machines where very high pressures are generated in the lubricant film support this prediction, but are open to the criticism that the fluid is subjected to a high pressure for such a short time ( ca . 10 -4 s) that an equilibrium state may not be reached. In the present investigation the appropriate condition of the lubricant is achieved, not by subjecting it to very high pressures but by maintaining it in the supercooled state. The lubricant is thus in a condition of equili­brium and the shear experiments are carried out at atmospheric pressure. The lubricant specimen is retained in a suitably adapted split Hopkinson torsion bar, and at the high rates of shear applied ( ca . 10 4 s -1 ) the shear stress at sufficiently low temperatures can exceed 5 MPa. By this tech­nique the shear pulse is applied for a sufficiently short time ( ca . 10 -3 s) to avoid viscous heating of the sample, which bedevils normal viscometry at high shear rates. Two fluids were tested: polyphenyl ether 5P4E and a mineral oil Shell HVI 650. Nonlinearity in the shear-stress-shear-strain-rate relation was found when the stress exceeded about 3 MPa. The elastic shear modulus G ∞ was also measured, yielding ca . 500 MPa for 5P4E and ca . 50 MPa for HVI 650.These values compare with ca . 1100 MPa and 300 MPa as found by the high-frequency oscillating shear technique at small strains.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 4025-4025
Author(s):  
Miguel A. Cruz ◽  
Katie E. Sowa ◽  
Scott M. Smith

Abstract Abstract 4025 Poster Board III-961 Recently, we described that the gain of function mutation R1450E in the A1 domain of von Willebrand factor (VWF) eliminates the formation of catch bond with glycoprotein (GP)Ibα, prolonging the bond lifetimes at low forces. Because those studies were performed with the mutant immobilized on a plastic surface, we further characterize the effect of this mutant on platelet function in solution and under shear stress. Both wild type (WT) and mutant A1A2A3 proteins were expressed in HEK293 cells and purified to homogeneity. The monomeric state of A1A2A3 proteins were assessed by gel filtration chromatography and neither of the proteins had formed dimers or any higher order aggregates. The recombinant A1A2A3 mutant bound spontaneously to GPIbα without the modulator ristocetin with a half-maximal binding observed at 65 ± 8 nM. This apparent dissociation constant was comparable to that of WT (50 ± 10 nM) in the presence of ristocetin. The mutant failed to induce spontaneous platelet aggregation under stirring conditions, and blocked 100% ristocetin-induced platelet agglutination (RIPA) at concentration of 250 nM. At the same concentration, the mutant increased shear-induced platelet aggregation (SIPA) at 500s-1 and 5000s-1 shear rates, reaching 42% and 66%, respectively, while SIPA did not exceed 18% in the presence of WT. The anti-αIIbβ3 antibody 7E3 blocked the effect of the mutant on SIPA. Blood was then incubated with the mutant (250 nM) and perfused over a surface coated with fibrin(ogen) at different shear rates. Blood containing WT resulted in <10% surface coverage by platelets after 1.5 minutes while platelets from blood containing the mutant rapidly bound covering 100% of the fibrin(ogen) surface area at 1500s-1. At shear rate of 2500s-1, surface coverage was 20% for the mutant and 0% for WT fragment. EDTA and antibodies 6D1 (GPIbα) and 10E5 (αIIbβ3) effectively blocked mutant-mediated platelet adhesion and thrombus formation under high shear rates. The addition of ristocetin (0.5 mg/ml) to whole blood prior perfusion reproduced the effect of the mutant. Here, we describe an A1A2A3 mutant that bound spontaneously to GPIbα but affected differently RIPA and SIPA. These results suggest that hydrodynamic forces directly act on the GPIbα-mutant A1A2A3 complex, regulating signaling. In addition, platelet activation induced by the binding of soluble mutant A1A2A3 or plasma VWF results in αIIbβ3-mediated platelet adhesion to fibrin(ogen) under high shear rates. Disclosures: No relevant conflicts of interest to declare.


2021 ◽  
Vol 8 (1) ◽  
pp. C29-C37
Author(s):  
T. Javanbakht ◽  
S. Laurent ◽  
D. Stanicki ◽  
I. Salzmann

The present study focuses on the rheological properties of polyethylene glycol (PEG) modified, positively charged, and negatively charged superparamagnetic iron oxide nanoparticles (SPIONs) at different temperatures. We hypothesized that the surface properties of these nanoparticles in the water did not affect their rheological properties. These nanoparticles had not the same surface properties as SPIONs-PEG had not to charge on their surface whereas positively charged and negatively charged ones with amine and carboxyl groups as their surfaces had positive and negative surface charges, respectively. However, their rheological behaviors were not different from each other. The comparative rheological study of SPIONs revealed their pseudo-Newtonian behavior. The viscosity of SPIONs decreased with the increase in temperature. At low shear rates, the shear stress of SPIONs was independent of rate and increased with the increase of rate. Moreover, at high shear rates, the shear stress for PEG-SPIONs was more than those for positively charged and negatively charged SPIONs. These measurements also revealed that at high shear rates, the shear stress of samples decreased with the increase of temperature. The shear stress of samples decreased with the increase of shear strain and the temperature. We also observed that all the samples had the same amount of shear strain at each shear stress, which indicated the exact resistance of SPIONs to deformation. Furthermore, the shear modulus decreased with time for these nanoparticles. These results suggest that these nanoparticles are promising candidates with appropriate properties for fluid processing applications and drug vectors in biomedical applications.


1996 ◽  
Vol 118 (1) ◽  
pp. 162-168 ◽  
Author(s):  
Y. Zhang ◽  
K. T. Ramesh

Knowledge of the behavior of lubricants over a wide range of pressures and shear rates is fundamental to an understanding of elastohydrodynamic (EHD) lubrication. The mechanical properties of elastohydrodynamic lubricants have been measured by a number of researchers under the conditions of low pressures and low shear rates, as well as under high pressures and high shear rates. This paper presents experimental results for the synthetic lubricant 5P4E subjected to moderate pressures (60 MPa to 700 MPa) and high shear rates (105 s−1) using the technique of pressure-shear plate impact. Thin layers (25 μm thick) of the lubricant are confined between two hard elastic plates; the assembly is subjected to impact by a parallel plate in a manner designed to induce both compression and shear loading. For approximately 1 μs the compressed lubricant is subjected to a simple shearing motion; during that time, continuous records of the shear stress and shear rate are obtained using laser interferometry. Three test configurations were used in order to cover the pressure range, and special techniques were developed for preparing the specimen sandwich. The pressure range covered includes both the liquid and glassy states of the lubricant. The results show that a limiting shear stress model is an appropriate model for lubricant behavior under these conditions. The experimental results also show little change in the lubricant shearing behavior across the glass transition.


1997 ◽  
Vol 17 (5) ◽  
pp. 919-924 ◽  
Author(s):  
Patrick André ◽  
Patricia Hainaud ◽  
Claire Bal dit Sollier ◽  
Leonard I. Garfinkel ◽  
Jacques P. Caen ◽  
...  

Open Ceramics ◽  
2021 ◽  
Vol 5 ◽  
pp. 100052
Author(s):  
V. Carnicer ◽  
C. Alcázar ◽  
M.J. Orts ◽  
E. Sánchez ◽  
R. Moreno

1991 ◽  
Vol 35 (4) ◽  
pp. 706-706
Author(s):  
Hideroh Takahashi ◽  
Yoshinori Inoue ◽  
Satoru Yamamoto ◽  
Osami Kamigaito

2011 ◽  
Vol 106 (12) ◽  
pp. 1062-1068 ◽  
Author(s):  
Naoki Tsuji ◽  
Yuko Honda ◽  
Chikako Kamisato ◽  
Yoshiyuki Morishima ◽  
Toshiro Shibano ◽  
...  

SummaryEdoxaban is an oral, direct factor Xa (FXa) inhibitor under late-phase clinical development. This study compared the antithrombotic efficacy of edoxaban with that of an indirect FXa inhibitor, fondaparinux, in in vivo venous and arterial thrombosis models and in ex vivo perfusion chamber thrombosis model under low and high shear rates in rats. Venous and arterial thrombi were induced by platinum wire insertion into the inferior vena cava and by application of FeCl3 to the carotid artery, respectively. The perfusion chamber thrombus was formed by blood perfusion into a collagen-coated capillary at 150 s-1 (low shear rate) and 1,600 s-1 (high shear rate). Effective doses of edoxaban that reduced thrombus formation by 50% (ED50) in venous and arterial thrombosis models were 0.076 and 0.093 mg/kg/h, respectively. In contrast, ED50 of fondaparinux in the arterial thrombosis model (>10 mg/kg/h) was markedly higher compared to ED50 in the venous thrombosis model (0.021 mg/kg/h). In the perfusion chamber thrombosis model, the ratio of ED50 under high shear rate (1.13 mg/kg/h) to that under low shear rate (0.63 mg/kg/h) for edoxaban was 1.9, whereas that for fondaparinux was more than 66. While the efficacy of fondaparinux markedly decreased in arterial thrombosis and in a high-shear state, edoxaban exerted consistent antithrombotic effects regardless of flow conditions. These results suggest that shear rate is a key factor in different antithrombotic effects between edoxaban and fondaparinux.


Sign in / Sign up

Export Citation Format

Share Document