Development of Effective Momentum Model for Steam Injection Through Multi-Hole Spargers: Unit Cell Model

2021 ◽  
Author(s):  
Xicheng Wang ◽  
Dmitry Grishchenko ◽  
Pavel Kudinov

Abstract The Steam injection through multi-hole spargers into the pressure suppression pool (PSP) is used in light water reactors to prevent containment over-pressure. The development of thermal stratification in the PSP can reduce its cooling capacity and results in higher containment pressures compared to completely mixed pool conditions. Explicit modelling of direct contact condensation (DCC) of steam at the steam-water interface is a challenge for contemporary codes. Effective Heat Source (EHS) and Effective Momentum Source (EMS) models have been proposed to enable the prediction of thermal stratification and mixing transients induced by steam condensation in a large pool. The general idea of the EHS/EMS is to resolve the effect of the DCC phenomena on a large pool, instead of explicit modelling of the small-scale phenomena at steam-water interface. The EHS/EMS models can be implemented using (i) respective boundary conditions at the boundary of the Steam Condensation Region (SCR) or (ii) using source terms in the heat and momentum transport equations. In previous work, EHS/EMS models were implemented using the second approach and validated against data from PPOOLEX and PANDA tests. It was found that results are sensitive to the spatial distribution of the source terms. Since the current data are not sufficient to provide a reasonable distribution, a preliminary study of the first method was done in this paper. The goal of this work is to develop a ‘Unit Cell’ model by using respective boundary conditions for steam injection through multi-hole sparger. The condensed turbulent jet is resolved by introducing the liquid jet with the same effective momentum and heat as the injected steam. A uniform velocity profile solved by EMS model and the temperature boundary solved by EHS model is provided on each injection hole of the sparger wall. Validation is conducted against sparger test in PANDA facilities.

Author(s):  
Xicheng Wang ◽  
Dmitry Grishchenko ◽  
Pavel Kudinov

Abstract The Pressure Suppression Pool (PSP) in a Boiling Water Reactor (BWR) is served as a heat sink to prevent containment over-pressure. The steam can be injected through the multi-hole spargers. The development of thermal stratification where a thermocline with a large temperature gradient appears in the pool can lead to the higher pressure in the dry well compared with completely mixing pool conditions. Prediction of the thermal phenomenon in the pool is necessary for the support of system design and operation. Thus, the Effective Heat Source (EHS) and Effective Momentum Source (EMS) models have been proposed. The models can be applied to CFD code by using (i) source terms in the transport equations or (ii) using respective boundary conditions at the Steam Condensation Region (SCR). Previous validation against PPOOLEX and PANDA tests using the source terms approach faced challenges in momentum distribution. Therefore, a preliminary investigation of using the second method was performed. The encouraging results implied that it is possible to further develop this approach. The goal of this work is to further develop the EHS/EMS models for the steam injection through a multi-hole sparger through the SCR model (i.e approach (ii)) and to validate it against the experimental data obtained from PANDA HP5 tests. Modeling guidelines are proposed. The temperature evolutions and vertical velocity profiles of these tests are compared to the simulation results. The agreement suggests that this model can provide an adequate estimation of the pool behavior.


2021 ◽  
Vol 506 ◽  
pp. 230192
Author(s):  
Yunxiang Chen ◽  
Jie Bao ◽  
Zhijie Xu ◽  
Peiyuan Gao ◽  
Litao Yan ◽  
...  

2011 ◽  
Vol 488-489 ◽  
pp. 759-762
Author(s):  
L.Y. Li ◽  
M.H. Aliabadi ◽  
Pi Hua Wen

A Meshfree approach for continuum damage modeling of 3D orthogonal woven composites is presented. Two different shape function constructions, Radial basis (RB) function and Moving kriging (MK) interpolation, are utilized corresponding with Galerkin method in the Meshfree approach. The failure of two different unit cell models, straight-edge and smooth fabric unit cell model respectively, is compared.


2018 ◽  
Vol 53 (11) ◽  
pp. 1425-1436
Author(s):  
PC Upadhyay ◽  
JP Dwivedi ◽  
VP Singh

Coefficients of thermal expansion of some uniaxially fiber-reinforced composites have been evaluated using three-phase unit-cell model. Results have been compared with the values predicted by two other models based on composite cylinders assembly (CCA), and also with some earlier reported experimental values. An extension of the two-phase unit-cell model has also been presented for the evaluation of thermal expansion coefficients of three-phase composites. The formulation has been used to evaluate the overall coefficients of thermal expansion of AS-graphite/epoxy system with a low modulus coating on the fibers. The results have been compared with the results obtained from the Sutcu's recursive concentric cylinders model for composites containing coated fibers. From the comparison of results of the unit-cell models (both, two-phase and three-phase) with the results obtained from some other models available in the literature, it is concluded that the overall thermal properties of fiber-reinforced composites evaluated by the unit-cell model can be used as effectively as by any other model.


2015 ◽  
Vol 118 ◽  
pp. 276-283 ◽  
Author(s):  
X.H. Yang ◽  
S.W. Ren ◽  
W.B. Wang ◽  
X. Liu ◽  
F.X. Xin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document