Maximum Likelihood Method for Energy Balance Error Correction in Heat Exchanger Data

Author(s):  
Young-Gil Park ◽  
Liping Liu ◽  
Anthony M. Jacobi

Heat exchanger performance data commonly contain redundant heat transfer rate measurements. Due to measurement uncertainties involved in the experiments, these redundant heat transfer rates have some discrepancies. While it is a common practice and adopted by engineering standards to use the arithmetic mean of heat transfer measurements, the resulting performance indicators of heat exchangers do not result in a minimum uncertainty possible. Also, this approach fails to resolve discrepancies in resulting transport performance parameters depending on the use of UA-LMTD method or effectiveness-NTU method. In this paper, heat exchanger performance data with two heat transfer measurements from hot and cold fluid streams are combined to produce a least uncertainty of the performance indicators. Individual measurements of mass flow rates and temperatures are corrected by most likely errors based on their respective uncertainties. The validity of this method has been demonstrated by Monte-Carlo simulations. Using air conditioning heat exchanger performance data under dry and wet surface conditions, it is demonstrated that the proposed method leads to a minimum uncertainty of the calculated variables.

Heat exchangers are prominent industrial applications where engineering science of heat transfer and Mass transfer occurs. It is a contrivance where transfer of energy occurs to get output in the form of energy transfer. This paper aims at finding a solution to improve the thermal performance in a heat exchanger by using passive method techniques. This experimental and numerical analysis deals with finding the temperature outlets of cold and hot fluid for different mass flow rates and also pressure drop in the tube and the annular side by adding an elliptical leaf strip in the pipe at various angles. The single elliptical leaf used in experiment has major to minor axes ratios as 2:1 and distance of 50 mm between two leaves are arranged at different angular orientations from 0 0 to 1800 with 100 intervals. Since it’s not possible to find the heat transfer rates and pressure drops at every orientation of elliptical leaf so a generalized regression neural network (GRNN) prediction tool is used to get outputs with given inputs to avoid experimentation. GRNN is a statistical method of determining the relationship between dependent and independent variables. The values obtained from experimentation and GRNN nearly had precise values to each other. This analysis is a small step in regard with encomiastic approach for enhancement in performance of heat exchangers


2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


2021 ◽  
Vol 9 (4B) ◽  
Author(s):  
Devanand D. Chillal ◽  
◽  
Uday C. Kapale ◽  
N.R. Banapurmath ◽  
T. M. Yunus Khan ◽  
...  

The work presented is an effort to realize the changes occurring for convective coefficients of heat transfer in STHX fitted with inclined baffles. Effort has been undertaken using Fluent, a commercially available CFD code ona CAD model of small STHX with inclined baffles with cold liquid flowing into the tubes and hot liquid flowing in the shell. Four sets of CFD analysis have been carried out. The hot liquid flow rate through shell compartments varied from 0.2 kg/sec to 0.8 kg/sec in steps of 0.2 kg/sec, while keeping the cold liquid flow condition in tube at 0.4 kg/sec constant. Heat transfer rates, compartment temperatures, and overall heat transfer coefficients, for cold liquid and hot liquid, were studied. The results given by the software using CFD approach were appreciable and comparatively in agreement with the results available by the experimental work, which was undertaken for the same set of inlet pressure conditions, liquid flow rates, and inlet temperatures of liquid for both hot and cold liquids. The experimental output results were also used to validate the results given by the CFD software. The results from the CFD analysis were further used to conclude the effect of baffle inclination on heat duty. The process thus followed also helped realize the effects of baffle inclination on convective heat transfer coefficient of the liquid flow through the shell in an inclined baffle shell and tube heat exchanger. The temperature plots for both cold and hot liquid were also generated for understanding the compartmental temperature distributions inclusive of the inlet and outlet compartments. The heat duty for a heat exchanger has been found to increase with the increase in baffle inclinations from zero degree to 20 degrees. Likewise, the convective heat transfer coefficients have also been found to increase with the increase in baffle inclinations.


1999 ◽  
Vol 121 (4) ◽  
pp. 241-246 ◽  
Author(s):  
F. E. M. Saboya ◽  
C. E. S. M. da Costa

From the second law of thermodynamics, the concepts of irreversibility, entropy generation, and availability are applied to counterflow, parallel-flow, and cross-flow heat exchangers. In the case of the Cross-flow configuration, there are four types of heat exchangers: I) both fluids unmixed, 2) both fluids mixed, 3) fluid of maximum heat capacity rate mixed and the other unmixed, 4) fluid of minimum heat capacity rate mixed and the other unmixed. In the analysis, the heat exchangers are assumed to have a negligible pressure drop irreversibility. The Counterflow heat exchanger is compared with the other five heat exchanger types and the comparison will indicate which one has the minimum irreversibility rate. In this comparison, only the exit temperatures and the heat transfer rates of the heat exchangers are different. The other conditions (inlet temperatures, mass flow rates, number of transfer units) and the working fluids are the same in the heat exchangers.


2012 ◽  
Vol 2012 (1) ◽  
pp. 000857-000865
Author(s):  
Aparna Aravelli ◽  
Singiresu S. Rao ◽  
Hari K. Adluru

Increase in the density of electronic packaging leads to the investigation of highly efficient thermal management systems. The challenge in these micro-systems is to maximize heat transfer per unit volume. In the author's previous work, experimental and computational analysis has been performed on LTCC substrates using embedded silver vias. This novel technique of embedding silver vias along with forced convection resulted in higher heat transfer rates. The present work further investigates into the optimization of this model. A Multi-objective optimization problem has been formulated for the heat transfer in the LTCC model. The Log Mean Temperature Difference (LMTD) method of heat exchangers has been used in the formulation. Optimization is done based on maximization of the total heat transferred and minimization of the coolant pumping power. Structural and thermal design variables are considered to meet the manufacturability and energy requirements. Demanded pressure loss and volume of the silver metal are used as constraints. The classical optimization technique Sequential Quadratic Programming (SQP) is used to solve the micro-heat exchanger problem. The optimal design is presented and sensitivity analysis results are discussed.


Author(s):  
J. Thavamani

Heat exchanger is the most important function in industrial sector for transferring heat energy to useful work. Heat transfer occurs between the cold fluid and hot fluid or from hot fluid to cold fluid in conduction and convection mode of through a heat exchanger wall. If heat transfer medium has very low thermal conductivity, it would have limited the efficiency of heat exchanger. Whenever the system is subjected to increased heat load, cooling is the main technical challenge for industries. The main objective of this work is to evaluate the effectiveness of shell and tube heat exchanger experimentally and analyse the flow behaviours of different nanofluids. In our experimental analysis, various nanofluids which consist of water and one percentage volume concentration of Al2O3, CuO and SiO2 passing through tube side in the shell and tube heat exchanger. The nano particle diameter is 70nm. The three dissimilar mass flow rates are considered for the experiments and their results are continuously monitored. The enhancement of heat transfer performance of CuO, Al2O3, SiO2 is compared with the base fluid water. Reynolds number values are calculated with three different mass flow rates and compared with heat transfer characteristics (LMTD, Nusselt number and overall heat transfer coefficient). SEM analysis, energy dispersive spectroscopy, X-ray diffraction of CuO, Al2O3 and SiO2.are conducted. The heat transfer effectiveness is increased by 22.12%, 19.46% and 1.47% respectively for CuO, Al2O3 and SiO2 when compared to base fluid.