Experimental Investigation of the Effect of Synthetic Jets on Local Heat Transfer Coefficients in Minichannels During Laminar and Turbulent Flow Conditions

Author(s):  
David M. Sykes ◽  
Andrew L. Carpenter ◽  
Gregory S. Cole

Microchannels and minichannels have been shown to have many potential applications for cooling high-heat-flux electronics over the past 3 decades. Synthetic jets can enhance minichannel performance by adding net momentum flux into a stream without adding mass flux. These jets are produced because of different flow patterns that emerge during the induction and expulsion stroke of a diaphragm, and when incorporated into minichannels can disrupt boundary layers and impinge on the far wall, leading to high heat transfer coefficients. Many researchers have examined the effects of synthetic jets in microchannels and minichannels with single-phase flows. The use of synthetic jets has been shown to augment local heat transfer coefficients by 2–3 times the value of steady flow conditions. In this investigation, local heat transfer coefficients and pressure loss in various operating regimes were experimentally measured. Experiments were conducted with a minichannel array containing embedded thermocouples to directly measure local wall temperatures. Flow regimes ranged from laminar to turbulent. Local wall temperature measurements taken directly beneath the synthetic jet in a laminar flow regime indicated that when a synthetic jet was used, the heat transfer coefficient was increased as much as 2.8 times the value as when synthetic jets were not used. Significant heat transfer coefficient augmentation also propagated to the upstream location, where heat transfer was increased to 2.2 times the value as when the synthetic jets were not used. Additional measurements show that synthetic jets significantly altered the pressure loss coefficient of the minichannels and that this effect was more pronounced in laminar flow than in turbulent flow. The effect of operating frequency on heat transfer and pressure loss is also presented. It was shown that the optimal operating point for the synthetic jet within a minichannel was in transitional to weakly turbulent flow (2600<Re<4500) to maximize the increase in heat transfer coefficient and minimize the increase in pressure loss.

Author(s):  
David M. Sykes ◽  
Andrew L. Carpenter ◽  
Gregory S. Cole

Microchannels and minichannels have been shown to have many potential applications for cooling high-heat-flux electronics over the past 3 decades. Synthetic jets can enhance minichannel performance by adding net momentum flux into a stream without adding mass flux. These jets are produced because of different flow patterns that emerge during the induction and expulsion stroke of a diaphragm, and when incorporated into minichannels can disrupt boundary layers and impinge on the far wall, leading to high heat transfer coefficients. Many researchers have examined the effects of synthetic jets in microchannels and minichannels with single-phase flows. The use of synthetic jets has been shown to augment local heat transfer coefficients by 2–3 times the value of steady flow conditions. In this investigation, local heat transfer coefficients and pressure loss in various operating regimes were experimentally measured. Experiments were conducted with a minichannel array containing embedded thermocouples to directly measure local wall temperatures. The experimental range extends from transitional to turbulent flows. Local wall temperature measurements indicate that increases of heat transfer coefficient of over 20% can occur directly below the synthetic jet with low exit qualities. In this study, the heat transfer augmentation by using synthetic jets was dictated by the momentum ratio of the synthetic jet to the bulk fluid flow. As local quality was increased, the heat transfer augmentation dropped from 23% to 10%. Surface tension variations had a large effect on the Nusselt number, while variations in inertial forces had a small effect on Nusselt number in this operating region.


2000 ◽  
Author(s):  
M. Kumagai ◽  
R. S. Amano ◽  
M. K. Jensen

Abstract A numerical and experimental investigation on cooling of a solid surface was performed by studying the behavior of an impinging jet onto a fixed flat target. The local heat transfer coefficient distributions on a plate with a constant heat flux were computationally investigated with a normally impinging axisymmetric jet for nozzle diameter of 4.6mm at H/d = 4 and 10, with the Reynolds numbers of 10,000 and 40,000. The two-dimensional cylindrical Navier-Stokes equations were solved using a two-equation k-ε turbulence model. The finite-volume differencing scheme was used to solve the thermal and flow fields. The predicted heat transfer coefficients were compared with experimental measurements. A universal function based on the wave equation was developed and applied to the heat transfer model to improve calculated local heat transfer coefficients for short nozzle-to-plate distance (H/d = 4). The differences between H/d = 4 and 10 due to the correlation among heat transfer coefficient, kinetic energy and pressure were investigated for the impingement region. Predictions by the present model show good agreement with the experimental data.


Author(s):  
V.B. Sapozhnikov ◽  
V.Yu. Mityakov ◽  
A.V. Mityakov ◽  
A.V. Vintsarevich ◽  
D.V. Gerasimov

We used gradient thermometry to determine local heat transfer coefficients on the fire deck surface. We studied two modes of engine operation, that is, motored and fired. We show that the heat transfer coefficient distribution over the fire deck surface is inhomogeneous. Our investigation results may be used to validate existing models of heat transfer in a combustion chamber.


2008 ◽  
Vol 62 (1) ◽  
Author(s):  
Magdalena Cudak ◽  
Joanna Karcz

AbstractExperimentally found local heat transfer coefficients are analyzed as a function of the measuring point on the heat transfer surface area of the agitated vessel wall and of the impeller eccentricity. Eccentric Rushton turbine and A 315 impeller are considered. Local heat transfer coefficients were measured by means of the computer-aided electrochemical method. The measurements were performed in an agitated vessel with inner diameter 0.3 m, filled with liquid up to the height equal to the vessel diameter. The experiments were carried out within the turbulent regime of the Newtonian liquid flow in the agitated vessel. The results were compared with the data obtained for the agitated vessel equipped with an eccentrically located axial flow propeller or an HE 3 impeller. Experimental studies show that the distributions of the heat transfer coefficient values depend on the impeller eccentricity, impeller type and the direction of the liquid circulation in the agitated vessel.


Author(s):  
A. M. Ai Dabagh ◽  
G. E. Andrews

The differences in the heat transfer coefficient between the pin and the wall in pin-fin heat transfer was determined for three pin length to diameter ratios. A staggered pin-fin array was used with a 50% duct flow blockage by the pins. The axial pitch-to-pin diameter ratio, X/D, was 1.5 and the transverse pitch-to-diameter ratio, S/D, was 2.0. Three pin length-to-diameter ratios, T/D, of 0.7. 1.0 and 2.2 were investigated. The mean heat transfer coefficient results were very similar to previous work for similar geometries. The axial variation of heat transfer coefficient showed this to be fairly uniform with a small peak at the fourth row. Around each pin four measurements of the heat transfer coefficients were made with four on the fin surface at each end. Thus 12 local heat transfer coefficients were made per pin-fin. These showed that for all three geometries the wall or fin heat transfer was always greater by 15–35% than the pin for the same velocity and Re.


Author(s):  
Saeid Vafaei ◽  
Dongsheng Wen

This work reports an experimental study of convective heat transfer of aqueous alumina nanofluids in a horizontal microchannel under laminar flow condition. The variation of local heat transfer coefficients, in both entrance and developed flow regime, is obtained as a function of axial distance. The heat transfer coefficient of nanofluids is found to be dependent upon not only nanoparticle concentration but also mass flow rate. Different to the behavior in conventional-sized channels, the major heat transfer coefficient enhancement is observed in fully developed region in microchannels. Discussions of the results suggest that the heterogeneous nature of nanoparticle flow should be considered.


Author(s):  
Andrew J. Neely ◽  
Peter T. Ireland ◽  
Les R. Harper

An experimental investigation of the performance of extended fin surfaces for the forced convective cooling of a range of engine component geometries in crossflow is reported. The experiments were undertaken to measure the surface heat transfer coefficient distributions of external finning around non-cylindrical geometries for use in aviation gas turbines in which the cooling performance/mass ratio must be maximised. The geometries examined were a box (square with rounded corners), a flute (rectangle with circular ends) and a 30° wedge. These models were sized to have equivalent cross sectional area to allow a direct comparison of performance. Perspex models coated with thermochromic liquid crystal were tested at a range of Reynolds numbers in a heat transfer wind tunnel in which a step change in flow temperature was used to measure the transient thermal behaviour of the fins. This technique enables the full surface mapping of local heat transfer coefficients on the surface of the fins. These measurements are compared with those for the equivalent smooth geometries and also with empirical calculations from the literature where available. A comparison with previous cylindrical measurements is also made. Knowledge of the distributions of local heat transfer coefficients enables the optimisation of the geometry through strategies such as baffling of the fins. Some examples of these strategies have been implemented and the results are reported. The finned geometries are seen to outperform the unfinned geometries (by factors greater than 3) though by factors less than simply the increase in area. The enhancement in h results because the increased surface area of the fins more than outweighs the decrease in local h on the fin surface as compared to the smooth geometries.


1999 ◽  
Author(s):  
Patrick H. Oosthuizen ◽  
David Naylor

Abstract A transient method, based on an inverse heat conduction solution, for experimentally determining the distribution of local heat transfer rates on the surface of a body has been numerically evaluated. The particular interest is in situations in which the heat transfer coefficients are relatively low and in which there are relatively large changes in the heat transfer coefficient over the surface of the body being considered. In the method, a solid body of the shape being investigated, constructed from a low conductivity material, is heated to a uniform temperature and then exposed to a test flow. Using a layer of temperature sensitive crystal placed over the surface of this model or by other means, the time taken for the temperature at a relatively small number of selected points on the surface to reach a selected value is determined. The surface heat flux rate distribution is then found from these measured times using a simple inverse heat conduction method. The feasibility of this method has been evaluated by considering relatively low Reynolds number flow over a square cylinder and natural convective flow over a circular cylinder. Known local heat transfer coefficient distributions for these situation have been applied as boundary conditions in the numerical solution of the transient cooling of a the “experimental” models. These solutions are used to generate “measured” data i.e. to generate simulated experimental data. The inverse heat transfer method has then been used to predict the local heat transfer coefficient distribution over the surface and the predicted and input distributions have been compared. The effect of uncertainties in the experimental measurements on this comparison has then been evaluated using various assumed uncertainty values. The results of the study indicate that the proposed method of measuring local heat transfer coefficients is capable of giving results of good accuracy.


Author(s):  
Joshua L. Nickerson ◽  
Martin Cerza ◽  
Sonia M. F. Garcia

The solution of the heat conduction equation in the liquid layer beneath a moving bubble’s base and the resulting local heat transfer coefficient are presented. An analytical model was constructed using separation of variables to solve the heat conduction equation for the thermal profile in the liquid film beneath the base of a bubble moving through a microchannel at a given velocity. Differentiating the resulting liquid thermal profile and applying the standard definition for the local heat transfer coefficient resulted in a solution for local heat transfer coefficient as a function of bubble length. Analysis included varying pertinent parameters such as film thickness beneath the bubble base, wall heat flux, and superheated temperature in the microchannel. Water and FC-72 were analyzed as prospective coolant fluids. Analytical data revealed that as the superheated temperature in the microchannel increases, local heat transfer coefficients increase and arrive at a higher steady-state value. Increasing wall heat flux achieved the same result, while increasing film thickness resulted in lower heat transfer coefficients. The model indicated that water had superior performance as a coolant, provided the dielectric fluid (FC-72) is not mandated.


Author(s):  
Thierry Some ◽  
Eckhard Lehmann ◽  
Hitoshi Sakamoto ◽  
Jungho Kim ◽  
Jin Taek Chung ◽  
...  

An important goal of spray cooling research is the ability to predict local heat transfer coefficient from the spray hydrodynamics. It is postulated in this work that the local pressure is the controlling parameter for local heat transfer coefficient. To test this hypothesis, local pressure and heat transfer data were obtained for a 1×1, 1×2, and 2×2 arrays of hollow cone sprays at two pressures and three standoff distances. A correlation between the pressure and heat transfer coefficient was determined, then used to “predict” the heat transfer coefficient from the pressure data. The local variations in heat transfer coefficient were captured well using this technique, and the area-averaged heat transfer coefficient could be predicted within 12.6%. The technique needs to be verified with different nozzles and fluids over a wider range of conditions.