A Near-Wall Interfacial Area Concentration Model to Predict Departure From Nucleate Boiling Critical Heat Flux Based on High Speed Video From Boiling Water Flows

Author(s):  
Evan T. Hurlburt ◽  
Helene A. Krenitsky ◽  
Richard C. Bauer

In nucleate boiling as the heat flux from the wall to the fluid is increased the heat transfer coefficient initially increases. At a sufficiently high heat flux called the critical heat flux (CHF) the heat transfer mechanism suddenly becomes less effective resulting in a rapid jump in wall temperature. In bubbly subcooled (or near-subcooled) conditions the CHF mechanism is referred to as departure from nucleate boiling. Departure from nucleate boiling (DNB) refers to the transition from nucleate boiling where liquid contacts the wall to film boiling in which a vapor layer contacts the wall. Various hypotheses have been used in modeling and predicting CHF. High speed video images of boiling water flows taken at Bettis Laboratory at the critical heat flux visually captured sufficient evidence of the DNB mechanism that improved insight into DNB modeling may be possible. This paper summarizes high speed video image analysis and the development of a new DNB critical heat flux model based on the image analysis findings. Using short window averages of image data, a significant increase in transmitted light intensity is seen near the wall just prior to CHF. The increase suggests that at CHF there is a transient reduction in the interfacial area concentration, ai, or bubble number density near the wall. This is believed to be the result of a sudden increase in bubble coalescence rates near the wall. The increase in coalescence rates results in a reduction in the interfacial area concentration causing it to reach a maximum at CHF. This near-wall maximum in ai at CHF under flow boiling conditions is consistent with recent pool boiling data in the literature. The image based observations motivated development of an interfacial area based CHF model to predict the maximum in the interfacial area concentration at CHF. The model predicts that a critical nucleation site density or a near-wall critical void fraction can be used as a DNB CHF criterion. This is a valuable simplification that can be directly implemented in three-dimensional thermal hydraulic codes. The critical nucleation site density result was used as an input to a simple wall heat transfer partition model to predict the critical heat flux. The model relies on correlation based estimates for the superheat temperature, bubble departure diameter, and bubble departure frequency. Model predictions are compared to CHF values taken from Groeneveld’s 2006 CHF look-up table.

1998 ◽  
Vol 120 (3) ◽  
pp. 641-653 ◽  
Author(s):  
G. F. Naterer ◽  
W. Hendradjit ◽  
K. J. Ahn ◽  
J. E. S. Venart

Boiling heat transfer from inclined surfaces is examined and an analytical model of bubble growth and nucleate boiling is presented. The model predicts the average heat flux during nucleate boiling by considering alternating near-wall liquid and vapor periods. It expresses the heat flux in terms of the bubble departure diameter, frequency and duration of contact with the heating surface. Experiments were conducted over a wide range of upward and downward-facing surface orientations and the results were compared to model predictions. More active microlayer agitation and mixing along the surface as well as more frequent bubble sweeps along the heating surface provide the key reasons for more effective heat transfer with downward facing surfaces as compared to upward facing cases. Additional aspects of the role of surface inclination on boiling dynamics are quantified and discussed.


Author(s):  
Muhamad Zuhairi Sulaiman ◽  
Masahiro Takamura ◽  
Kazuki Nakahashi ◽  
Tomio Okawa

Boiling heat transfer (BHT) and critical heat flux (CHF) performance were experimentally studied for saturated pool boiling of water-based nanofluids. In present experimental works, copper heaters of 20 mm diameter with titanium-oxide (TiO2) nanocoated surface were produced in pool boiling of nanofluid. Experiments were performed in both upward and downward facing nanofluid coated heater surface. TiO2 nanoparticle was used with concentration ranging from 0.004 until 0.4 kg/m3 and boiling time of tb = 1, 3, 10, 20, 40, and 60 mins. Distilled water was used to observed BHT and CHF performance of different nanofluids boiling time and concentration configurations. Nucleate boiling heat transfer observed to deteriorate in upward facing heater, however; in contrast effect of enhancement for downward. Maximum enhancements of CHF for upward- and downward-facing heater are 2.1 and 1.9 times, respectively. Reduction of mean contact angle demonstrate enhancement on the critical heat flux for both upward-facing and downward-facing heater configuration. However, nucleate boiling heat transfer shows inconsistency in similar concentration with sequence of boiling time. For both downward- and upward-facing nanocoated heater's BHT and CHF, the optimum configuration denotes by C = 400 kg/m3 with tb = 1 min which shows the best increment of boiling curve trend with lowest wall superheat ΔT = 25 K and critical heat flux enhancement of 2.02 times.


1999 ◽  
Author(s):  
Yasuo Koizumi ◽  
Hiroyasu Ohtake ◽  
Manabu Mochizuki

Abstract The effect of solid particle introduction on subcooled-forced flow boiling heat transfer and a critical heat flux was examined experimentally. In the experiment, glass beads of 0.6 mm diameter were mixed in subcooled water. Experiments were conducted in a range of the subcooling of 40 K, a velocity of 0.17–6.7 m/s, a volumetric particle ratio of 0–17%. When particles were introduced, the growth of a superheated liquid layer near a heat trasnsfer surface seemed to be suppressed and the onset of nucleate boiling was delayed. The particles promoted the condensation of bubbles on the heat transfer surface, which shifted the initiation of a net vapor generation to a high heat flux region. Boiling heat trasnfer was augmented by the particle introduction. The suppression of the growth of the superheated liquid layer and the promotion of bubble condensation and dissipation by the particles seemed to contribute that heat transfer augmentation. The wall superheat at the critical heat flux was elevated by the particle introduction and the critical heat flux itself was also enhanced. However, the degree of the critical heat flux improvement was not drastic.


Author(s):  
Hongsheng Yuan ◽  
Sichao Tan ◽  
Kun Cheng ◽  
Xiaoli Wu ◽  
Chao Guo ◽  
...  

The flow rate can fluctuate in offshore nuclear power systems which are exposed to wind and waves, as well as in loops where flow instabilities occur, resulting in different thermal-hydraulic characteristics compared with that under steady flow. Among the thermal-hydraulic characteristics, onset of nucleate boiling (ONB) model determines whether the fluid is boiling, and boiling heat transfer is crucial to equipment performance and safety, both being key issues in subcooled flow boiling. Therefore, an experimental study was conducted to investigate how an imposed periodic flow oscillation affects the boiling inception and heat transfer of subcooled flow boiling of water in a vertical tube. The experiments were conducted under atmospheric pressure with the average flow rate ranging from 96kg/m2s to 287kg/m2s and heat flux ranging from 10kW/m2 to 197kW/m2. The relative pulsatile amplitude range is 0.1–0.3 and pulsatile period range is 10s-30s. Photographic images and thermal parameters such as temperatures and flow rate were recorded. The lack of nucleation site on the heated surface of the test section results in high wall superheat at ONB. The effects of pulsatile amplitude and period on superheat at boiling onset and average heat transfer were analyzed. The results show that the superheat at boiling inception is decreased when the average heat flux is lower than the heat flux at boiling inception of the corresponding steady flow, and the superheat at boiling onset is increased when the average heat flux is higher than the heat flux at boiling onset of the corresponding steady flow. The above effect of flow rate pulsation on superheat increases with increasing amplitude and decreasing period, and the mechanism can be explained by boiling nucleation theory. The lack of large active nucleation site also affects the boiling heat transfer. By comparing the contribution of nucleate boiling to heat transfer with the widely used Cooper’s pool boiling correlation, the subcooled flow boiling was found suppressed by convection. The average heat transfer of both the intermittent flow boiling and the single phase flow is influenced by flow oscillation.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
S. R. Darr ◽  
J. W. Hartwig ◽  
J. Dong ◽  
H. Wang ◽  
A. K. Majumdar ◽  
...  

Recently, two-phase cryogenic flow boiling data in liquid nitrogen (LN2) and liquid hydrogen (LH2) were compared to the most popular two-phase correlations, as well as correlations used in two of the most widely used commercially available thermal/fluid design codes in Hartwig et al. (2016, “Assessment of Existing Two Phase Heat Transfer Coefficient and Critical Heat Flux on Cryogenic Flow Boiling Quenching Experiments,” Int. J. Heat Mass Transfer, 93, pp. 441–463). Results uncovered that the correlations performed poorly, with predictions significantly higher than the data. Disparity is primarily due to the fact that most two-phase correlations are based on room temperature fluids, and for the heating configuration, not the quenching configuration. The penalty for such poor predictive tools is higher margin, safety factor, and cost. Before control algorithms for cryogenic transfer systems can be implemented, it is first required to develop a set of low-error, fundamental two-phase heat transfer correlations that match available cryogenic data. This paper presents the background for developing a new set of quenching/chilldown correlations for cryogenic pipe flow on thin, shorter lines, including the results of an exhaustive literature review of 61 sources. New correlations are presented which are based on the consolidated database of 79,915 quenching points for a 1.27 cm diameter line, covering a wide range of inlet subcooling, mass flux, pressure, equilibrium quality, flow direction, and even gravity level. Functional forms are presented for LN2 and LH2 chilldown correlations, including film, transition, and nucleate boiling, critical heat flux, and the Leidenfrost point.


Author(s):  
Robert Stephenson ◽  
Jiajun Xu

In this study, a combination of synchronized high-speed video (HSV) and infrared (IR) thermography was used to characterize the nucleation, growth and detachment of bubbles generated during nucleate boiling inside the nanoemulsion fluid. The Ethanol/Polyalphaolefin nanoemulsion fluid was formed by dispersing ethanol nanodroplets into base fluid Polyalphaolefin, in which these nanodroplets can serve as the pre-seed boiling nuclei. With this unique combination, it allows controlled nucleation, time-resolved temperature distribution data for the boiling surface and direct visualization of the bubble cycle to track bubble nucleation and growth. Data gathered included measurements of bubble growth versus time, as well as 2D temperature history of the heater surface underneath the bubbles. Our findings demonstrate a significant difference of bubble dynamics between the nanoemulsion fluid and pure ethanol, which may also account for the substantial increase in heat transfer coefficient and critical heat flux of nanoemulsion fluid. It is also observed here that the bubbles occurred inside the nanoemulsion fluid appear to be more uniform and two orders-of-magnitude larger in size. While the growth rate of the bubbles inside pure ethanol was found to be heat diffusion controlled at a coefficient around ½, which however, dropped to be around 0.3 for nanoemulsion fluid. Further study on this unique system will help reveal its heat transfer mechanisms.


Micromachines ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 980
Author(s):  
Kairui Tang ◽  
Jingjing Bai ◽  
Siyu Chen ◽  
Shiwei Zhang ◽  
Jie Li ◽  
...  

With the rapid development of electronics, thermal management has become one of the most crucial issues. Intense research has focused on surface modifications used to enhance heat transfer. In this study, multilayer copper micromeshes (MCMs) are developed for commercial compact electronic cooling. Boiling heat transfer performance, including critical heat flux (CHF), heat transfer coefficients (HTCs), and the onset of nucleate boiling (ONB), are investigated. The effect of micromesh layers on the boiling performance is studied, and the bubbling characteristics are analyzed. In the study, MCM-5 shows the highest critical heat flux (CHF) of 207.5 W/cm2 and an HTC of 16.5 W(cm2·K) because of its abundant micropores serving as nucleate sites, and outstanding capillary wicking capability. In addition, MCMs are compared with other surface structures in the literature and perform with high competitiveness and potential in commercial applications for high-power cooling.


2001 ◽  
Vol 1 (1) ◽  
pp. 32
Author(s):  
P. M. Carrica ◽  
V. Masson

We present the results of an experimental study of the effects of externally imposed electric fields on boiling heat transfer and critical heat flux (CHF) in dielectric fluids. The study comprises the analysis of geometries that, under the effects of electric fields, cause the bubbles either to be pushed toward the heater or away from it. A local phase detection probe was used to measure the void fraction and the interfacial impact rate near the heater. It was found that the critical heat flux can be either augmented or reduced with the application of an electric field, depending on the direction of . In addition, the heat transfer can be slightly enhanced or degraded depending on the heat flux. The study of the two-phase flow in nucleate boiling, only for the case of favorable dielectrophoretic forces, reveals that the application of an electric field reduces the bubble detection time and increases the detachment frequency. It also shows that the two-phase flow characteristics of the second film boiling regime resemble more a nucleate boiling regime than a film boiling regime.


1993 ◽  
Vol 115 (1) ◽  
pp. 78-88 ◽  
Author(s):  
C. O. Gersey ◽  
I. Mudawar

The effects of chip protrusion on the forced-convection boiling and critical heat flux (CHF) of a dielectric coolant (FC-72) were investigated. The multi-chip module used in the present study featured a linear array of nine, 10 mm x 10 mm, simulated microelectronic chips which protruded 1 mm into a 20-mm wide side of a rectangular flow channel. Experiments were performed in vertical up flow with 5-mm and 2-mm channel gap thicknesses. For each configuration, the velocity and subcooling of the liquid were varied from 13 to 400 cm/s and 3 to 36° C, respectively. The nucleate boiling regime was not affected by changes in velocity and subcooling, and critical heat flux generally increased with increases in either velocity or subcooling. Higher single-phase heat transfer coefficients and higher CHF values were measured for the protruded chips compared to similar flush-mounted chips. However, adjusting the data for the increased surface area and the increased liquid velocity above the chip caused by the protruding chips yielded a closer agreement between the protruded and flush-mounted results. Even with the velocity and area adjustments, the most upstream protruded chip had higher single-phase heat transfer coefficients and CHF values for high velocity and/or highly-subcooled flow as compared the downstream protruded chips. The results show that, except for the most upstream chip, the performances of protruded chips are very similar to those of flush-mounted chips.


1959 ◽  
Vol 81 (3) ◽  
pp. 230-236 ◽  
Author(s):  
R. Siegel ◽  
C. Usiskin

A photographic study was made to determine the qualitative effect of zero gravity on the mechanism of boiling heat transfer. The experimental equipment included a container for boiling water and a high-speed motion-picture camera. To eliminate the influence of gravity, these were mounted on a platform which was allowed to fall freely approximately 8 ft. During the free fall, photographs were taken of boiling from various surface configurations such as electrically heated horizontal and vertical ribbons. The heat flux was varied to produce conditions from moderate nucleate boiling to burnout. The results indicate that gravity plays a considerable role in the boiling process, especially in connection with the motion of vapor within the liquid.


Sign in / Sign up

Export Citation Format

Share Document