Determination of Dimensionality of Pool Boiling on a Thin Horizontal Disk Under Subcooled Conditions Using Thin-Film Thermocouples

2008 ◽  
Author(s):  
Vijaykumar Sathyamurthi ◽  
Debjyoti Banerjee

Subcooled pool boiling experiments are conducted at subcooling levels of 10 °C on a thin silicon disk (∼ 400μm thickn, 3 – inch diameter) with in situ micro-machined K-type thin film thermocouples (TFT) using a perfluorocarbon liquid refrigerant (PF-5060) with a boiling point of 56 °C. The experimental apparatus is of constant heat flux type. Surface temperature (from TFT) and heat flux data is obtained at each steady state condition to generate the pool boiling curve. The time – delay embedding technique is used to re-construct higher dimensional vectors with the optimal delay being estimated from the first minimum of mutual information. The correlation dimension measure is then estimated from the delay re – constructed phase space vectors. In this preliminary study correlation dimension measures are seen to vary from ∼ 12 in nucleate boiling, to ∼ 7 – 9 near Critical Heat Flux (CHF) condition, and ∼ 7 – 8 in film boiling. The results suggest that the attractors underlying thermal transport mechanisms in nucleate boiling are affected by a greater number of parameters than that at CHF. The dimension of the attractor is reduced further in the film boiling regime.

2009 ◽  
Vol 131 (7) ◽  
Author(s):  
V. Sathyamurthi ◽  
H-S. Ahn ◽  
D. Banerjee ◽  
S. C. Lau

Pool boiling experiments were conducted with three horizontal, flat, silicon surfaces, two of which were coated with vertically aligned multiwalled carbon nanotubes (MWCNTs). The two wafers were coated with MWCNT of two different thicknesses: 9 μm (Type-A) and 25 μm (Type-B). Experiments were conducted for the nucleate boiling and film boiling regimes for saturated and subcooled conditions with liquid subcooling of 0–30°C using a dielectric fluorocarbon liquid (PF-5060) as test fluid. The pool boiling heat flux data obtained from the bare silicon test surface were used as a base line for all heat transfer comparisons. Type-B MWCNT coatings enhanced the critical heat flux (CHF) in saturated nucleate boiling by 58%. The heat flux at the Leidenfrost point was enhanced by a maximum of ∼150% (i.e., 2.5 times) at 10°C subcooling. Type-A MWCNT enhanced the CHF in nucleate boiling by as much as 62%. Both Type-A MWCNT and bare silicon test surfaces showed similar heat transfer rates (within the bounds of experimental uncertainty) in film boiling. The Leidenfrost points on the boiling curve for Type-A MWCNT occurred at higher wall superheats. The percentage enhancements in the value of heat flux at the CHF condition decreased with an increase in liquid subcooling. However the enhancement in heat flux at the Leidenfrost points for the nanotube coated surfaces increased with liquid subcooling. Significantly higher bubble nucleation rates were observed for both nanotube coated surfaces.


Author(s):  
Vijaykumar Sathyamurthi ◽  
Debjyoti Banerjee

Saturated pool boiling experiments are conducted over silicon substrates with and without Multi-walled Carbon Nanotubes (MWCNT) with PF-5060 as the test fluid. Micro-fabricated thin film thermocouples located on the substrate acquire surface temperature fluctuation data at 1 kHz frequency. The high frequency surface temperature data is analyzed for the presence of chaotic dynamics. The shareware code, TISEAN© is used in analysis of the temperature time-series. Results show the presence of low-dimensional deterministic chaos, near Critical Heat Flux (CHF) and in some parts of the Fully Developed Nucleate Boiling (FDNB) regime. Some evidence of chaotic dynamics is also obtained for the film boiling regimes. Singular value decomposition is employed to generate pseudo-phase plots of the attractor. In contrast to previous studies involving multiple nucleation sites, the pseudo-phase plots show the presence of multi-fractal structure at high heat fluxes and in the film boiling regime. An estimate of invariant quantities such as correlation dimensions and Lyapunov exponents reveals the change in attractor geometry with heat flux levels. No significant impact of surface texturing is visible in terms of the invariant quantities.


1999 ◽  
Vol 123 (2) ◽  
pp. 399-400 ◽  
Author(s):  
Z. W. Liu ◽  
W. W. Lin ◽  
D. J. Lee ◽  
X. F. Peng

This work reported the boiling characteristics of FC-72 and HFE-7100 at atmospheric pressure and at a liquid subcooling of 0–20 K. The FC-72 exhibits a more efficient nucleate boiling mode and a higher critical heat flux (CHF) than the HFE-7100. For film boiling mode, HFE-7100 becomes more efficient.


Author(s):  
Lin Chen ◽  
Fengchu Jin ◽  
Jiahua Li ◽  
Yanchao Lv ◽  
Qingyang Wang ◽  
...  

Author(s):  
Muhamad Zuhairi Sulaiman ◽  
Masahiro Takamura ◽  
Kazuki Nakahashi ◽  
Tomio Okawa

Boiling heat transfer (BHT) and critical heat flux (CHF) performance were experimentally studied for saturated pool boiling of water-based nanofluids. In present experimental works, copper heaters of 20 mm diameter with titanium-oxide (TiO2) nanocoated surface were produced in pool boiling of nanofluid. Experiments were performed in both upward and downward facing nanofluid coated heater surface. TiO2 nanoparticle was used with concentration ranging from 0.004 until 0.4 kg/m3 and boiling time of tb = 1, 3, 10, 20, 40, and 60 mins. Distilled water was used to observed BHT and CHF performance of different nanofluids boiling time and concentration configurations. Nucleate boiling heat transfer observed to deteriorate in upward facing heater, however; in contrast effect of enhancement for downward. Maximum enhancements of CHF for upward- and downward-facing heater are 2.1 and 1.9 times, respectively. Reduction of mean contact angle demonstrate enhancement on the critical heat flux for both upward-facing and downward-facing heater configuration. However, nucleate boiling heat transfer shows inconsistency in similar concentration with sequence of boiling time. For both downward- and upward-facing nanocoated heater's BHT and CHF, the optimum configuration denotes by C = 400 kg/m3 with tb = 1 min which shows the best increment of boiling curve trend with lowest wall superheat ΔT = 25 K and critical heat flux enhancement of 2.02 times.


Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


Author(s):  
Bao H. Truong

Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed a CHF enhancement up to 68% and there seems to be a monotonic relationship between the nanoparticle concentration and the magnitude of enhancement. Alumina nanofluids had a CHF enhancement up to 56% but the peak occurred at the intermediate concentration. The boiling curves in nanofluid were found to shift to the left of that of water and correspond to higher nucleate boiling heat transfer coefficients in the two-phase flow regime. Scanning Electron Microscopy (SEM) images show a porous coating layer of nanoparticles on wires subjected to nanofluid CHF tests. These coating layers change the morphology of the heater’s surface, and are responsible for the CHF enhancement. The thickness of the coating was estimated using SEM and was found ranging from 3.0 to 6.0 micrometers for Alumina, and 3.0 to 15.0 micrometers for Silica.


Sign in / Sign up

Export Citation Format

Share Document