Conjugate Heat Transfer Analysis for Laminated Cooling Effectiveness: Part B — Effects of Film Hole Incline Angle

Author(s):  
Qinghua Deng ◽  
Weilun Zhou ◽  
Zhenping Feng

The laminated cooling or multi-layered impingement-effusion cooling, which originates from combustion liner cooling, is believed to be an advanced and promising gas turbine blade cooling technique. Previous authors’ works have found that surface curvatures have different influences on overall cooling effectiveness of laminated cooling. To determine the optimal configuration of laminated cooling for various surface curvatures respectively, the conjugate heat transfer approach that has been validated by the experimental data was employed to study numerically the effects of streamwise incline angles (including 15, which was 20 degree for flat plate and concave surface, 30, 60 and 90 degree) on overall cooling effectiveness with different surface curvatures. The results show that the shallower film holes restrain the liftoff of the coolant ejection, and lead to a higher overall cooling effectiveness. However, shallower injection angle causes higher pressure loss. The relationship between injection angle and overall cooling effectiveness for different curvature is illustrated in the paper. The results indicate that shallower injection angle provides more than 10% improvement of cooling effectiveness compared to that of 90° injection angle for flat plate, concave surface and convex surface with smaller curvature at high blowing ratio. But for convex surface with large curvature, blowing ratio of 0.7 to 0.9 is better for overall cooling effectiveness, and shallower injection angle has little effect on cooling effectiveness. Moreover, additional pressure loss occurs to shallower injection angle because of the serious flow separation.

Author(s):  
Weilun Zhou ◽  
Qinghua Deng ◽  
Zhenping Feng

The laminated cooling or multi-layered impingement-effusion cooling, which originates from combustor liner cooling, combines impingement jet, rib-roughed and film cooling and results in a high overall cooling effectiveness. It’s believed to be a promising gas turbine blade cooling technique. In this paper, conjugate heat transfer analysis that has been validated by the experimental results was carried out for five laminated cooling models with different surface curvatures at a certain range of blowing ratio. The numerical results show that the curvature and blowing ratio have crucial effects on laminated cooling effectiveness. High blowing ratio results in a better overall cooling effectiveness for flat plate and concave surface, while the moderate blowing ratio performances better on convex surface. Film cooling has an interaction with the internal convective and impingement cooling, thus the optimal cooling effectiveness of laminated cooling is achieved at the condition that the improvement of internal cooling counteracts the deterioration of film cooling, instead of the condition that film cooling or internal cooling reaches the maximum respectively. Moreover, concave surfaces have the higher pressure loss in the whole range of blowing ratio, while convex surfaces have lower pressure loss than flat plate due to the turbulence intensity of external flow.


2021 ◽  
Vol 2116 (1) ◽  
pp. 012051
Author(s):  
A K Jaiswal ◽  
P S Mahapatra ◽  
B V S S S Prasad

Abstract A computation fluid dynamics analysis is presented to investigate the effect of placing a microchannel inside a flat plate. A microchannel embedded flat plate with 250 angled 175 film holes in staggered form is considered in the present work. A Conjugate heat transfer analysis is done to determine the efficiency of cooling. Simulations were carried out, and subsequently, a parametric study was conducted to observe the effect of variation of blowing ratios. The temperature distribution is observed to be more uniform due to the presence of the microchannel, resulting in a lesser thermal gradient in the solid plate. It is also noted that overall effectiveness increases with the blowing ratio. The maximum increase in overall effectiveness due to the microchannel is about 30% for the blowing ratio of unity.


Author(s):  
Devaraj K

Abstract: The present computational study involves a flat plate subjected to combined effect of jet impingement and film cooling. A conjugate heat transfer model in conjunction with k-ω SST turbulence model is employed to study the turbulence effects. The effect of Reynolds number varying from 389 to 2140 on static temperature, Nusselt number and film cooling effectiveness has be discussed for the blowing ratios of 0.6, 0.8, 1.0. The variation in the size of vortices formed on the impinging surface with Reynolds number is studied. It has been observed that the local Nusselt number shows a rising trend with the increase in Reynolds number, while the static temperatures follow the downfall in its values. As a result, an enhancement in the effectiveness is observed, which is credited to the capabilities of combined impingement and film cooling. At Reynolds number of 972, the coolant jet is found to be attached to the surface, for this condition the heat transfer phenomena for blowing ratios of 0.6, 0.8, 1.0, 1.2, 1.6, 2.0, 2.4, 2.6 are studied to understand the flow distribution on the plate surface. Keywords: Jet impingement, film cooling, effectiveness, conjugate heat transfer


2021 ◽  
Vol 143 (2) ◽  
Author(s):  
Fu-qiang Wang ◽  
Jian Pu ◽  
Jian-hua Wang ◽  
Wei-dong Xia

Abstract Film-hole can be often blocked by thermal-barrier coatings (TBCs) spraying, resulting in the variations of aerodynamic and thermal performances of film cooling. In this study, a numerical study of the blockage effect on the film cooling effectiveness of inclined cylindrical-holes was carried out on a concave surface to simulate the airfoil pressure side. Three typical blowing ratios (BRs) of 0.5, 1.0, and 1.5 were chosen at an engine-similar density ratio (DR) of 2.0. Two common inclination angles of 30 deg and 45 deg were designed. The blockage ratios were adjusted from 0 to 20%. The results indicated the blockage could enhance the penetration of film cooling flow to the mainstream. Thus, the averaged effectiveness and coolant coverage area were reduced. Moreover, the pressure loss inside of the hole was increased. With the increase of BR, the decrement of film cooling effectiveness caused by blockage rapidly increased. At BR = 1.5, the decrement could be acquired up to 70% for a blockage ratio of 20%. The decrement of film cooling effectiveness caused by blockage was nearly nonsensitive to the injection angle; however, the larger angle could generate the higher increment of pressure loss caused by blockage. A new design method for the couple scheme of film cooling and TBC was proposed, i.e., increasing the inlet diameter according to the blockage ratio before TBC spraying. In comparison with the original unblocked-hole, the enlarged blocked-hole not only kept the nearly same area-averaged effectiveness but also reduced slightly the pressure loss inside of the hole. Unfortunately, application of enlarged blocked-hole at large BR could lead to a more obvious reduction of effectiveness near hole-exit, in comparison with the original common-hole.


Author(s):  
Juan He ◽  
Qinghua Deng ◽  
Weilun Zhou ◽  
Wei He ◽  
Tieyu Gao ◽  
...  

Abstract Double wall cooling, consisting of internal impingement cooling and external film cooling, is an advanced cooling method of gas turbines. In this paper, the flow and conjugate heat transfer characteristics of double wall cooling which has a film plate with gradient thickness are analyzed numerically. The detailed overall cooling effectiveness distributions are obtained by solving steady three dimensional Reynolds-averaged Navier-Stokes equations. In the double wall cooling scheme, seven vertical film holes and six impingement holes are staggered with same diameter (D), and the hole pitch of them are both set to 6D in flow direction and lateral direction. The gradient thickness along the flow direction is realized by setting the angle (α) between the lower surface of the film plate and the horizontal plane at −1.5 deg and 1.5 deg respectively. By comparing the results of four broadly used turbulence models with experimental data, SST k-ω is selected as the optimal turbulence model for double wall cooling analysis in this paper. In addition, the number of grids are finally determined to be 5.2 million by grid sensitivity calculation. The influence of the thickness gradient on the overall cooling effectiveness is revealed by comparing with the constant thickness film plate (Baseline 1 and 2), and all the cases are performed under four various coolant mass flow rates, which correspond to blowing ratios ranging from 0.25 to 1.5. The calculated results show that the thickening of the film plate downstream is beneficial to improve overall cooling effectiveness at low blowing ratio, which is benefit from two aspects. One is the thicken film plate weakens the flow separation in film hole and velocity of film hole outlet, another is the thicken film plate makes the impingement channels convergence, and impingement cooling is strengthened to some extent. However, with the increase of blowing ratio, the increasing trend gradually weakens due to the jet-off and limited impinge ability. For thickening film plate, the variations of the double wall cooling configurations are considered at initial film plate thickness tf of 2D and 3D, it is found that the ability to improve the overall cooling effectiveness by thickening the film plate downstream decrease as the initial film plate thickness increases, which is due to the increase of heat transfer resistance, and another finding is the cooling effectiveness of downstream thickening film plate with initial thickness of 2D is higher than that of 3D, which will provide a theoretical foundation both for improving cooling performance and reducing turbine blade weight at the same time. The influence of initial impingement gap H is also observed, and the study come to the fact that the best cooling performance occurred in H = 2D.


2013 ◽  
Vol 26 (4) ◽  
pp. 708-714
Author(s):  
Girish Oppattaiyamath ◽  
Nagarjuna Reddy ◽  
Satyapramod Jammy ◽  
Vinayak Kulkarni

Author(s):  
Young Seok Kang ◽  
Dong-Ho Rhee ◽  
Sanga Lee ◽  
Bong Jun Cha

Abstract Conjugate heat transfer analysis method has been highlighted for predicting heat exchange between fluid domain and solid domain inside high-pressure turbines, which are exposed to very harsh operating conditions. Then it is able to assess the overall cooling effectiveness considering both internal cooling and external film cooling at the cooled turbine design step. In this study, high-pressure turbine nozzles, which have three different film cooling holes arrangements, were numerically simulated with conjugate heat transfer analysis method for predicting overall cooling effectiveness. The film cooling holes distributed over the nozzle pressure surface were optimized by minimizing the peak temperature, temperature deviation. Additional internal cooling components such as pedestals and rectangular rib turbulators were modeled inside the cooling passages for more efficient heat transfer. The real engine conditions were given for boundary conditions to fluid and solid domains for conjugate heat transfer analysis. Hot combustion gas properties such as specific heat at constant pressure and other transport properties were given as functions of temperature. Also, the conductivity of Inconel 718 was also given as a function of temperature to solve the heat equation in the nozzle solid domain. Conjugate heat transfer analysis results showed that optimized designs showed better cooling performance, especially on the pressure surface due to proper staggering and spacing hole-rows compared to the baseline design. The overall cooling performances were offset from the adiabatic film cooling effectiveness. Locally concentrated heat transfer and corresponding high cooling effectiveness region appeared where internal cooling effects were overlapped in the optimized designs. Also, conjugate heat transfer analysis results for the optimized designs showed more uniform contours of the overall cooling effectiveness compared to the baseline design. By varying the coolant mass flow rate, it was observed that pressure surface was more sensitive to the coolant mass flow rate than nozzle leading edge stagnation region and suction surface. The CHT results showed that optimized designs to improve the adiabatic film cooling effectiveness also have better overall cooling effectiveness.


Author(s):  
Cuong Q. Nguyen ◽  
Perry L. Johnson ◽  
Bryan C. Bernier ◽  
Son H. Ho ◽  
Jayanta S. Kapat

Data from conical-shaped film cooling holes is extremely sparse in open literature, especially the cooling uniformity characteristic, an important criterion for evaluating any film cooling design. The authors will compare the performance of conical-shaped holes to cylindrical-shaped holes. Cylindrical-shaped holes are often considered a baseline in terms of film cooling effectiveness and cooling uniformity coefficient. The authors will study two coupons with conical-shaped holes, which have 3° and 6° diffusion angles, named CON3 and CON6 respectively. A conjugate heat transfer computational fluid dynamics model and an experimental wind tunnel will be used to study these coupons. The three configurations: cylindrical baseline, CON3, and CON6, have a single row of holes with an inlet metering diameter of 3mm, length-to-nominal diameter of 4.3, and an injection angle of 30°. In this study, the authors will also take into account the heat transfer into the coolant flow from the coolant channel. In other words, coolant temperature at the exit of the coolant hole will be different than that measured at the inlet, and the conjugate heat transfer model will be used to correct for this difference. For the numerical model, the realizable k-ε turbulent model will be applied with a second order of discretization and enhanced wall treatment to provide the highest accuracy available. Grid independent studies for both cylindrical-shaped film cooling holes and conical-shaped holes will be performed and the results will be compared to data in open literature as well as in-house experimental data. Results show that conical-shaped holes considerably outperform cylindrical-shaped holes in film cooling effectiveness at all blowing ratios. In terms of cooling uniformity, conical-shaped holes perform better than cylindrical-shaped holes for low and mid-range blowing ratios, but not at higher levels.


Author(s):  
Jason E. Albert ◽  
David G. Bogard

Film cooling performance is typically quantified by separating the external convective heat transfer from the other components of the conjugate heat transfer that occurs in turbine airfoils. However, it is also valuable to assess the conjugate heat transfer in terms of the overall cooling effectiveness, which is a parameter of importance to airfoil designers. In the current study, adiabatic film effectiveness and overall cooling effectiveness values were measured for the pressure side of a simplified turbine vane model with three rows of showerhead cooling at the leading edge and one row of body film cooling holes on the pressure side. This was done by utilizing two geometrically identical models made from different materials. Adiabatic film effectiveness was measured using a very low thermal conductivity material, and the overall cooling effectiveness was measured using a material with a higher thermal conductivity selected such that the Biot number of the model matched that of a turbine vane at engine conditions. The theoretical basis for this matched-Biot number modeling technique is discussed in some detail. Additionally, two designs of pressure side body film cooling holes were considered in this study: a standard design of straight, cylindrical holes and an advanced design of “trenched” cooling holes in which the hole exits were situated in a recessed, transverse trench. This study was performed using engine representative flow conditions, including a coolant-to-mainstream density ratio of DR = 1.4 and a mainstream turbulence intensity of Tu = 20%. The results of this study show that adiabatic film and overall cooling effectiveness increase with blowing ratio for the showerhead and pressure side trenched holes. Performance decreases with blowing ratio for the standard holes due to coolant jet separation from the surface. Both body film designs have similar performance at a lower blowing ratio when the standard hole coolant jets remain attached. Far downstream of the cooling holes both designs perform similarly because film effectiveness decays more rapidly for the trenched holes.