Effects of Film Hole Exit Radiusing on Film Cooling Performance

Author(s):  
Antar M. M. Abdala ◽  
Fifi N. M. Elwekeel ◽  
Qun Zheng

In the present study, theoretical investigation of film cooling effectiveness and heat transfer behavior for radiusing of film hole exit was evaluated. Seven rounding radii of R=0.0D, 0.06D, 0.08D, 0.1D, 0.3D, 0.5D and 0.8D were investigated. The film cooling effectiveness, the heat transfer coefficient, net heat flux ratio and discharge coefficient were investigated. Four mass flow rates in the range of 0.00044: 0.0018[kg/s] were used to investigate the effects of coolant velocity on the film cooling performance. Results show that using the film hole exit radiusing helps in improvement the film cooling effectiveness. The radius of R=0.5D shows higher film cooling effectiveness among the other radii. The spatially average laterally film cooling effectiveness and net heat flux ratio of R=0.5D outperforms the case of R=0.0D at all mass flow rates except at higher rates the values are lower. Discharge coefficient of R=0.5D shows enhancement than R=0.0D with the pressure ratios. Interpretation of the low and high heat transfer coefficient regions for radii of R=0.5D and R= 0.0D depending on the flow structures was explained in detail.

Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo

To investigate the effects of the inclined ribs on internal flow structure in film hole and the film cooling performance on outer surface, experimental and numerical studies are conducted on the effects of rib orientation angle on film cooling of compound cylindrical holes. Three coolant channel cases, including two ribbed cross-flow channels (135° and 45° angled ribs) and the plenum case, are studied under three blowing ratios (0.5, 1.0 and 2.0). 2D contours of film cooling effectiveness as well as heat transfer coefficient were measured by transient liquid crystal measurement technique (TLC). The steady RANS simulations with realizable k-ε turbulence model and enhanced wall treatment were performed. The results show that the spanwise width of film coverage is greatly influenced by the rib orientation angle. The spanwise width of the 45° rib case is obviously larger than that of the 135° rib case under lower blowing ratios. When the blowing ratio is 1.0, the area-averaged cooling effectiveness of the 135° rib case and the 45° rib case are higher than that of the plenum case by 38% and 107%, respectively. With the increase of blowing ratio, the film coverage difference between different rib orientation cases becomes smaller. The 45° rib case also produces higher heat transfer coefficient, which is higher than the 135° rib case by 3.4–8.7% within the studied blowing ratio range. Furthermore, the discharge coefficient of the 45° rib case is the lowest among the three cases. The helical motion of coolant flow is observed in the hole of 45° rib case. The jet divides into two parts after being blown out of the hole due to this motion, which induces strong velocity separation and loss. For the 135° rib case, the vortex in the upper half region of the secondary-flow channel rotates in the same direction with the hole inclination direction, which leads to the straight streamlines and thus results in lower loss and higher discharge coefficient.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo ◽  
Ying-ni Zhai

This paper presents an experimental and numerical investigation on the film cooling with different coolant feeding channel structures. Two ribbed cross-flow channels with rib-orientation of 135° and 45° respectively and the plenum coolant channel have been studied and compared to find out the effect of rib orientation on the film cooling performances of cylindrical holes. The film cooling effectiveness and heat transfer coefficient were measured by the transient heat transfer measurement technique with narrow-band thermochromic liquid crystal. Numerical simulations with realizable k-ε turbulence model were also performed to analyze the flow mechanism. The results show that the coolant channel structure has a notable effect on the flow structure of film jet which is the most significant mechanism affecting the film cooling performance. Generally, film cooling cases fed with ribbed cross-flow channels have asymmetric counter-rotating vortex structures and related asymmetric temperature distributions, which make the film cooling effectiveness and the heat transfer coefficient distributions asymmetric to the hole centerline. The discharge coefficient of the 45° rib case is the lowest among the three cases under all the blowing ratios. And the plenum case has higher discharge coefficient than the 135° rib case under low blowing ratio. With the increase of blowing ratio, the discharge coefficient of the 135° rib case gets larger than the plenum case gradually, because the vortex in the upper half region of the coolant channel rotates in the same direction with the film hole inclination direction and makes the jet easy to flow into the film hole in the 135° rib case.


Author(s):  
H. I. Oguntade ◽  
G. E. Andrews ◽  
A. D. Burns ◽  
D. B. Ingham ◽  
M. Pourkashanian

Conjugate heat transfer CFD was undertaken on the influence of hole size on effusion cooling. The coupled thermal mixing between the hot-gas and coolant jets and the heat transfer within the effusion walls were modelled using the ANSYS FLUENT software. The heat and mass transfer analogy was employed to predict the adiabatic film cooling effectiveness separately from the overall cooling effectiveness by adding a tracer gas to the coolant air and predicting its concentration at the inner wall surface. The geometries predicted were those investigated experimentally by Andrews and his co-workers using a 152mm length of effusion cooling with 10 rows of square array holes in a flat metal wall. Effusion of X/D of 4.6 and 1.85 were investigated at constant X, the large hole diameter at the lower X/D drastically reduces the hole blowing rate and this improves the film cooling and deteriorates the internal wall cooling. The CFD predictions enable these qualitative effects to be investigated in more detail. The agreement of predictions and experiment was very good at low coolant mass flow rates, but under-predicted the measurements at higher flow rates by about 5–12%. The experimental results showed that the smaller X/D gave a better overall cooling performance and the predictions also showed this, but demonstrated that it was not just to due improved effusion film cooling as there was not the expected large reduction in internal wall cooling.


Author(s):  
Alok Dhungel ◽  
Yiping Lu ◽  
Wynn Phillips ◽  
Srinath V. Ekkad ◽  
James Heidmann

The primary focus of this paper is to study the film cooling performance for a row of cylindrical holes each supplemented with two symmetrical anti vortex holes which branch out from the main holes. The anti-vortex design was originally developed at NASA-Glenn Research Center by Dr. James Heidmann, co-author of this paper. This “anti-vortex” design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film cooling holes. The geometry and orientation of the anti vortex holes greatly affect the cooling performance downstream, which is thoroughly investigated. By performing experiments at a single mainstream Reynolds number of 9683 based on the free stream velocity and film hole diameter at four different coolant-to-mainstream blowing ratio of 0.5, 1, 1.5, 2 and using the transient IR thermography technique, detailed film cooling effectiveness and heat transfer coefficients are obtained simultaneously from a single test. When the anti vortex holes are nearer to the primary film cooling holes and are developing from the base of the primary holes, better film cooling is accomplished as compared to other anti vortex hole orientations. When the anti vortex holes are laid back in the upstream region, film cooling diminishes considerably. Although an enhancement in heat transfer coefficient is seen in cases with high film cooling effectiveness, the overall heat flux ratio as compared to standard cylindrical holes is much lower. Thus cases with anti vortex holes placed near the main holes certainly show promising results.


Author(s):  
D. H. Zhang ◽  
L. Sun ◽  
Q. Y. Chen ◽  
M. Lin ◽  
M. Zeng ◽  
...  

Embedding a row of typical cylindrical holes in a transverse slot can improve the cooling performance. Rectangular slots can increase the cooling effectiveness but is at the cost of decreasing of discharge coefficients. An experiment is conducted to examine the effects of an overlying transverse inclined trench on the film cooling performance of axial holes. Four different trench configurations are tested including the baseline inclined cylindrical holes. The influence of the geometry of the upstream lip of the exit trench and the geometry of the inlet trench on cooling performance is examined. Detailed film cooling effectiveness and heat transfer coefficients are obtained separately using the steady state IR thermography technique. The discharge coefficients are also acquired to evaluate the aerodynamic performance of different hole configurations. The results show that the film cooling holes with both ends embedded in slots can provide higher film cooling effectiveness and lower heat transfer coefficients; it also can provide higher discharge coefficients whilst retaining the mechanical strength of a row of discrete holes. The cooling performance and the aerodynamic performance of the holes with both ends embedded in inclined slots are superior to the holes with only exit trenched. To a certain extent, the configuration of the upstream lip of the exit trench affects the cooling performance of the downstream of the trench. The filleting for the film hole inlet avail the improvement of the cooling effect, but not for the film hole outlet. Comparing film cooling with embedded holes to unembedded holes, the overall heat flux ratio shows that the film holes with both ends embedded in slots and filleting for the film hole inlet can produce the highest heat flux reduction.


Author(s):  
Scott Lewis ◽  
Brett Barker ◽  
Jeffrey P. Bons ◽  
Weiguo Ai ◽  
Thomas H. Fletcher

Experiments were conducted to determine the impact of synfuel deposits on film cooling effectiveness and heat transfer. Scaled up models were made of synfuel deposits formed on film-cooled turbine blade coupons exposed to accelerated deposition. Three distinct deposition patterns were modeled: a large deposition pattern (max deposit peak ≅ 2 hole diameters) located exclusively upstream of the holes, a large deposition pattern (max deposit peak ≅ 1.25 hole diameters) extending downstream between the cooling holes, and a small deposition pattern (max deposit peak ≅ 0.75 hole diameter) also extending downstream between the cooling holes. The models featured cylindrical holes inclined at 30 degrees to the surface and aligned with the primary flow direction. The spacing of the holes were 3, 3.35, and 4.5 hole diameters respectively. Flat models with the same film cooling hole geometry and spacing were used for comparison. The models were tested using blowing ratios of 0.5–2 with a turbulent approach boundary layer and 0.5% freestream turbulence. The density ratio was approximately 1.1 and the primary flow Reynolds number at the film cooling row location was 300,000. An infrared camera was used to obtain the film cooling effectiveness from steady state tests and surface convective heat transfer coefficients using transient tests. The model with upstream deposition caused the primary flow to lift off the surface over the roughness peaks and allowed the coolant to stay attached to the model. Increasing the blowing ratio from 0.5 to 2 only expanded the region that the coolant could reach and improved the cooling effectiveness. Though the heat transfer coefficient also increased at high blowing ratios, the net heat flux ratio was still less than unity, indicating film cooling benefit. For the two models with deposition between the cooling holes, the free stream air was forced into the valleys in line with the coolant holes and degraded area-averaged coolant performance at lower blowing ratios. It is concluded that the film cooling effectiveness is highest when deposition is limited to upstream of the cooling holes. When accounting for the insulating effect of the deposits between the film holes, even the panels with deposits downstream of the film holes can yield a net decrease in heat flux for some cases.


2020 ◽  
Vol 142 (12) ◽  
Author(s):  
Guohua Zhang ◽  
Jian Liu ◽  
Bengt Sundén ◽  
Gongnan Xie

Abstract Existing researches on two-row film cooling mainly focused on double-jet film cooling. However, researches on the effects by combining different kinds of hole shapes on film cooling performance are quite limited. In order to improve the film cooling effectiveness, the three-dimensional numerical method is utilized to investigate the effects of a novel structure composed of two-row holes with different shapes and arrangements on the adiabatic film cooling effectiveness with the blowing ratio of M = 1.5. To achieve this purpose, 30 different cases with two-row holes are designed and their film cooling effectiveness are compared with those of other seven cases with a single hole. Cases with two-row holes are designed by setting cylindrical, elliptical, or super-elliptical holes as the first-row, and arranging cylindrical holes with 30 deg, 45 deg, 60 deg, and 90 deg compound angles as the second row. The realizable k–ɛ turbulence model with enhanced wall function is utilized for all cases under identical boundary conditions. Similar film cooling performances are observed for cases with elliptical and super-elliptical holes being the first row, since the maximum deviation of film cooling effectiveness is less than 10%. It is found that the case integrates both a cylindrical hole and a cylindrical hole with 90 deg compound angle can greatly improve the film cooling performance with a higher discharge coefficient. However, the staggered case with an elliptical hole as both first- and second row gives the best film cooling effectiveness and the worst discharge coefficient due to the biggest resistance for the coolant flowing into the film hole.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Qi-jiao He ◽  
Gang Xie

The trailing edge of the high-pressure turbine blade presents significant challenges to cooling structure design. To achieve better cooling performance at turbine blade trailing edge, a novel ribbed cutback structure is proposed for trailing edge cooling, which has rib structures on the cutback surface for heat transfer enhancement. In this study, numerical simulations have been performed on the effects of V-shaped rib angle on the film cooling characteristics and flow physics. Three V-shaped rib angles of 30°, 45° and 60° are studied. The distributions of adiabatic cooling effectiveness and heat transfer coefficient are obtained under blowing ratios with the value of 0.5, 1.0 and 1.5 respectively. Due to the relatively small rib height, the effect of V-shaped ribs on the film cooling effectiveness is not notable. The disadvantage of V-shaped ribs mainly exhibits at the downstream area of cutback surface. With the increase of V-shaped rib angle, the film cooling effectiveness becomes lower, but the values are still above 0.9. The V-shaped ribs obviously enhance the heat transfer on trailing edge cutback surface. The area-averaged heat transfer coefficient of the V-rib case is higher than that of the smooth case by 26.3–41.2%. The 45° V-rib case has higher heat transfer intensity than the other two V-shaped rib cases under all the three blowing ratios. However, the heat transfer coefficient distribution of the 60° V-rib case is more uniform. The heat transfer intensity of the 30° V-rib case is higher in the downstream region than the other two cases, but lower in the upstream region in which the difference becomes smaller with the increase of blowing ratio. The 45° V-rib case and the 60° V-rib case both reach the maximum value of area-averaged heat transfer intensity under blowing ratio is 1.0. Under higher blowing ratio, the 30° V-rib case and the 45° V-rib case outperform 2.1% and 6.7% higher value relative to the 60° V-rib case respectively due to the smaller velocity gradient in the 60° V-rib case in the downstream.


1999 ◽  
Vol 121 (2) ◽  
pp. 225-232 ◽  
Author(s):  
R. J. Goldstein ◽  
P. Jin ◽  
R. L. Olson

A special naphthalene sublimation technique is used to study the film cooling performance downstream of one row of holes of 35 deg inclination angle with 3d hole spacing and relatively small hole length to diameter ratio (L/d = 6.3). Both film cooling effectiveness and mass/heat transfer coefficient are determined for blowing rates from 0.5 to 2.0 with density ratio of 1.0. The mass transfer coefficient is measured using pure air film injection, while the film cooling effectiveness is derived from comparison of mass transfer coefficients obtained following injection of naphthalene-vapor-saturated air with those from pure air injection. This technique enables one to obtain detailed local information on film cooling performance. The laterally averaged and local film cooling effectiveness agree with previous experiments. The difference between mass/heat transfer coefficients and previous heat transfer results indicates that conduction error may play an important role in the earlier heat transfer measurements.


1985 ◽  
Vol 107 (2) ◽  
pp. 313-320 ◽  
Author(s):  
P. M. Ligrani ◽  
C. Camci

A variable property correction is given for turbulent boundary layers that are film-cooled using staggered rows of injection holes inclined at 35 deg. With the correction, a relation is provided between the adiabatic film cooling effectiveness for constant property flow and heat transfer coefficients for variable property flow, which are based on the difference between the freestream recovery temperature and wall temperature. The variable property correction was determined from heat transfer measurements for a range of injection parameters at different values of the nondimensional coolant temperature and from results in the literature. Because the flow is compressible, the importance of the injection mass flux ratio, momentum flux ratio, and velocity ratio are considered in the determination of effectiveness.


Sign in / Sign up

Export Citation Format

Share Document