Flow and Heat Transfer in a Triple-Impingement Configuration for Trailing-Edge Cooling

Author(s):  
J. Liu ◽  
A. Weaver ◽  
T. I-P. Shih ◽  
J. Klinger ◽  
B. Heneveld ◽  
...  

The trailing-edge region of turbine airfoils is difficult to cool. In this study, CFD conjugate analysis based on the shear-stress transport (SST) turbulence model is used to study the flow and heat transfer in a triple-impingement cooling configuration. Parameters studied include the pressure drop across the configuration (1, 2, 3, 4, and 5 bars), and the heat transfer coefficient on the hot-gas side (2,000, 4,000, and 6,000 W/m2-K). In all cases with conjugate analysis, the temperature of the coolant at the inlet of the cooling passage is 673 K, the external hot-gas temperature is 1,755 K, and the static pressure at the exit of cooling passage is 25 bars. Simulations were also performed in which the temperature of the cooling-passage wall is kept constant at 1,173 K. Results are generated to show the nature of the flow induced by the triple impingement and how that flow affects heat transfer to the turbine material.

2005 ◽  
Vol 128 (1) ◽  
pp. 196-205 ◽  
Author(s):  
P. Martini ◽  
A. Schulz ◽  
H.-J. Bauer

The present study deals with trailing edge film cooling on the pressure side cutback of gas turbine airfoils. Before being ejected tangentially onto the inclined cut-back surface the coolant air passes a partly converging passage that is equipped with turbulators such as pin fins and ribs. The experiments are conducted in a generic setup and cover a broad variety of internal cooling designs. A subsonic atmospheric open-loop wind tunnel is utilized for the tests. The test conditions are characterized by a constant Reynolds number of Rehg=250000, a turbulence intensity of Tuhg=7%, and a hot gas temperature of Thg=500K. Due to the ambient temperature of the coolant, engine realistic density ratios between coolant and hot gas can be realized. Blowing ratios cover a range of 0.20<M<1.25. The experimental data to be presented include discharge coefficients, adiabatic film cooling effectiveness, and heat transfer coefficients in the near slot region (x∕H<15). The results clearly demonstrate the strong influence of the internal cooling design and the relatively thick pressure side lip (t∕H=1) on film cooling performance downstream of the ejection slot.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4327
Author(s):  
Min-Seob Shin ◽  
Santhosh Senguttuvan ◽  
Sung-Min Kim

The present study experimentally and numerically investigates the effect of channel height on the flow and heat transfer characteristics of a channel impingement cooling configuration for various jet Reynolds numbers in the range of 2000–8600. A single array consisting of eleven jets with 0.8 mm diameter injects water into the channel with 2 mm width at four different channel heights (3, 4, 5, and 6 mm). The average heat transfer coefficients at the target surface are measured by maintaining a temperature difference between the jet exit and the target surface in the range of 15–17 °C for each channel height. The experimental results show the average heat transfer coefficient at the target surface increases with the jet Reynolds number and decreases with the channel height. An average Nusselt number correlation is developed based on 85 experimentally measured data points with a mean absolute error of less than 4.31%. The numerical simulation accurately predicts the overall heat transfer rate within 10% error. The numerical results are analyzed to investigate the flow structure and its effect on the local heat transfer characteristics. The present study advances the primary understanding of the flow and heat transfer characteristics of the channel impingement cooling configuration with liquid jets.


Author(s):  
Dieter E. Bohn ◽  
Volker J. Becker

This paper presents the numerical investigations of the flow and heat transfer of two configurations of a transonic turbine guide vane. The basic configuration is a vane with convection cooling. The second configuration is additionally coated with a thermal barrier consisting of ZrO2. The results are obtained with a conjugate heat transfer and flow computer code that has been developed at the Institute of Steam and Gas Turbines. Measurement data is available for the basic configuration and the computational results are compared to the experimental results. The results show very good agreement between calculated and measured vane surface temperatures. The trailing edge turns out to be subjected to high thermal loads as it is too thin to be cooled effectively. Secondary flow phenomena like the passage vortex and the corner vortex and their impact on the temperature distribution are discussed. The ZrO2 coating is calculated for a thickness of 300μm. The substrate material temperatures are lowered by about 20 K–29 K in the stagnation point area and by about 27 K–43 K in the shock area on the suction side. At the trailing edge, the coating on the suction side and on the pressure side hardly influences the metal temperature.


Author(s):  
E. E. Donahoo ◽  
C. Camci ◽  
A. K. Kulkarni ◽  
A. D. Belegundu

There are many heat transfer augmentation methods that are employed in turbine blade design, such as impingement cooling, film cooling, serpentine passages, trip strips, vortex chambers, and pin fins. The use of crosspins in the trailing edge section of turbine blades is commonly a viable option due to their ability to promote turbulence as well as supply structural integrity and stiffness to the blade itself. Numerous crosspin shapes and arrangements are possible, but only certain configurations offer high heat transfer capability while maintaining taw total pressure loss. This study preseots results from 3-D numerical simulations of airflow through a turbine blade internal cooling passage. The simulations model viscous flow and heat transfer over full crosspins of circular cross-section with fixed height-to-diameter ratio of 0.5, fixed transverse-to-diameter spacing ratio of 1.5, and varying streamwise spacing. Preliminary analysis indicates that endwall effects dominate the flow and heat transfer at lower Reynolds numbers. The flow dynamics involved with the relative dose proximity of the endwalls for such short crosspins have a definite influeoce on crosspin efficiency for downstream rows.


Author(s):  
Shuping P. Chen ◽  
Peiwen W. Li ◽  
Minking K. Chyu ◽  
Frank J. Cunha ◽  
William Abdel-Messeh

Described in this paper is an experimental study of heat transfer over a trailing edge configuration preceded with an internal cooling channel of pedestal array. The pedestal array consists of both circular pedestals and oblong shaped blocks. Downstream to the pedestal array, the trailing edge features pressure side cutback partitioned by the oblong shaped blocks. The local heat transfer coefficient over the entire wetted surface in the internal cooling chamber has been determined by using a “hybrid” measurement technique based on transient liquid crystal imaging. The hybrid technique employs the transient conduction model in a semi-infinite solid for resolving the heat transfer coefficient on the endwall surface uncovered by the pedestals. The heat transfer coefficient over a pedestal can be resolved by the lumped capacitance method with an assumption of low Biot number. The overall heat transfer for both the pedestals and endwalls combined shows a significant enhancement compared to the case with thermally developed smooth channel. Near the downstream most section of the suction side, the land, due to pressure side cutback, is exposed to the stream mixed with hot gas and discharged coolant. Both the adiabatic effectiveness and heat transfer coefficient on the land section are characterized by using the transient liquid crystal technique.


2018 ◽  
Vol 140 (10) ◽  
Author(s):  
Andrew F. Chen ◽  
Hao-Wei Wu ◽  
Nian Wang ◽  
Je-Chin Han

Experimental investigation on rotation and turning vane effects on heat transfer was performed in a two-pass rectangular internal cooling channel. The channel has an aspect ratio of AR = 2:1 and a 180 deg tip-turn, which is a scaled up model of a typical internal cooling passage of gas turbine airfoils. The leading surface (LS) and trailing surface (TS) are roughened with 45 deg angled parallel ribs (staggered P/e = 8, e/Dh = 0.1). Tests were performed in a pressurized vessel (570 kPa) where higher rotation numbers (Ro) can be achieved with a maximum Ro = 0.42. Five Reynolds numbers (Re) were examined (Re = 10,000–40,000). At each Reynolds number, five rotational speeds (Ω = 0–400 rpm) were considered. Results showed that rotation effects are stronger in the tip regions as compared to other surfaces. Heat transfer enhancement up to four times was observed on the tip wall at the highest rotation number. However, heat transfer enhancement is reduced to about 1.5 times with the presence of a tip turning vane at the highest rotation number. Generally, the tip turning vane reduces the effects of rotation, especially in the turn portion.


Author(s):  
Thomas E. Dyson ◽  
David G. Bogard ◽  
Sean D. Bradshaw

Computational simulations using RANS and the k-ω SST turbulence model were performed to complement experimental measurements of overall cooling effectiveness and adiabatic film effectiveness for a film cooled turbine vane airfoil. Particular attention was placed on the showerhead. The design made use of five rows of showerhead holes and a single gill row on both pressure and suction sides. The simulated geometry also included the internal impingement cooling configuration. Internal and external boundary conditions were matched to experiments using the same vane model. To correctly simulate conjugate heat transfer effects, the experimental vane model was constructed to match the Biot number for engine conditions. Computational predictions of the overall and adiabatic effectiveness were compared to experimental measurements from both the conducting vane and a model constructed from low conductivity foam. The results show that the k-ω SST RANS model over-predicts both adiabatic and overall effectiveness due in part to limited jet diffusion. The simulations were also used to investigate heat transfer augmentation, which is difficult to measure experimentally in the showerhead region. The results showed substantial augmentation of 1.5 or more over large portions of the leading edge, with many areas exceeding 2.0. However, the simulations also showed a reduction in heat transfer (i.e., hf/h0 < 1) for locations beneath the coolant jets. This result was likely due to Taw being an inappropriate driving temperature for separated jets.


Sign in / Sign up

Export Citation Format

Share Document