Numerical Investigation of the Effect of Jet-Flaps in a Transonic Turbine Cascade With Subsonic Operating Conditions

Author(s):  
Ping-Ping Chen ◽  
Wei-Yang Qiao ◽  
Pu-Wei Wang

The objective of this article is to analyze numerically the effect of jet-flap on transonic high-pressure turbine cascades, which is one of usable flow control methods for a variable-geometry turbine (VGT). This paper is mainly on the discussion of the effect of different jet-flap design parameters with subsonic operating conditions: jet mass flow rate, jet slot location, jet blowing direction and jet slot width. With two-dimensional steady simulations, the jet-flap changes the cascade turning, the passage throat velocity distribution and throat area effectively, which will then contribute to a different turbine performance. Using a Cm = 2% pressure side (PS) jet-flap with 1.025mm slot width and counter-axial (-x) jet blowing direction, the incoming mass flow rate is diminished by 16.7%, the turning angle augmented by 3.7 degrees, but with an extended total-pressure loss coefficient from 0.05 (no jets) to 0.09.

2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Abdulghani Ramadan ◽  
Khairi Muftah ◽  
Abdulfattah Al-Kelani ◽  
Ali Abdulmalek ◽  
Akram Essnid ◽  
...  

A solar powered desalination unit which working on a humidification –dehumidification technique (HDH) is one of the most important techniques used in brackish and seawater desalination especially in remote and rural areas. In the present study, a test-rig was designed and constructed for conducting a set of experiments on a solar assisted desalination unit working on a HDH principle under the prevailing conditions of Tajoura-Libya. Experiments were carried out on specified days in March, 2019 at the laboratories of Center for Solar Energy Research and Studies (CSERS) at Tajoura. The effect of different design parameters and operating conditions on the performance of the unit and its productivity is closely investigated and interpreted. Results show that the productivity of the HDH unit decreases by increasing the process air mass flow rate. A significant improvement in the productivity of the unit is noticed when the feed water mass flow rate to the humidifier is increased. Furthermore, initial water temperature inside the tank has a remarked effect on the productivity of the unit. In order to obtain a reasonable amount of fresh water, the temperature of the water inside the tank should be increased. Increasing the cooling water mass flow rate to the dehumidifier leads to a corresponding decrease in the surface temperature of the cooling coil and hence the productivity of the unit is improved. The Productivity of the unit is varying from its lower value of (0.903 kg/m2.day) to a higher value of (6.47 kg/m2.day). These values are obtained for one meter square of solar air heater area. Gained Output Ratio (GOR) values range from a minimum of (0.082) to a maximum of (0.572). It is reasonable when compared to ones in literature for the water-heated HDH units.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


Author(s):  
Kang Song ◽  
Devesh Upadhyay ◽  
Hui Xie

Control-oriented models of turbocharger processes such as the compressor mass flow rate, the compressor power, and the variable geometry turbine power are presented. In a departure from approaches that rely on ad hoc empirical relationships and/or supplier provided performance maps, models based on turbomachinery physics and known geometries are attempted. The compressor power model is developed using Euler’s equations of turbomachinery, where the gas velocity exiting the rotor is estimated from an empirically identified correlation for the ratio between the radial and tangential components of the gas velocity. The compressor mass flow rate is modeled based on mass conservation, by approximating the compressor as an adiabatic converging-diverging nozzle with compressible fluid driven by external work input from the compressor wheel. The variable geometry turbine power is developed with Euler’s equations, where the turbine exit swirl and the gas acceleration in the vaneless space are neglected. The gas flow direction into the turbine rotor is assumed to align with the orientation of the variable geometry turbine vane. The gas exit velocity is calculated, similar to the compressor, based on an empirical model for the ratio between the turbine rotor inlet and exit velocities. A power loss model is also proposed that allows proper accounting of power transfer between the turbine and compressor. Model validation against experimental data is presented.


2021 ◽  
Author(s):  
Jingrui Yang ◽  
Qian Ma ◽  
Lingtong Han ◽  
Peiwei Sun

Abstract NuScale is a small nuclear reactor that relies on natural circulation. Its modular production and inherent safety can not only be used to generate electricity in some remote areas, but also provide energy for water desalination and regional heating. However, the dynamic characteristics of the NuScale are different from those of the traditional PWRs because of its passive characteristic. Therefore, it is necessary to study and analyze the system dynamic characteristics of NuScale. The NuScale PWR model is established based on MATLAB&Simulink. It includes point-reactor kinetics model with six groups delayed neutrons, coolant system and steam generator system. The model is established based on the conservation equations of mass, energy and momentum. And the correctness of the model is verified by the comparison between the steady-state calculation results and the design parameters. Transient calculation results are verified by mechanism analysis. To evaluate the dynamic characteristics of NuScale, the sine function changes with different frequencies in reactor reactivity and feedwater mass flow rate are introduced. The amplitude and phase responses of reactor power, secondary loop steam pressure, secondary loop mass flow rate, secondary loop steam temperature, and coolant average temperature are recorded. Then the Bode plot can be drawn with amplitude and phase responses in different frequencies. To evaluate the NuScale dynamic characteristics, frequency domain analysis is performed.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


2018 ◽  
Vol 204 ◽  
pp. 06007
Author(s):  
Mohammad Mahardika

Every year, Indonesia's population increase so as energy demand. To fulfill Indonesia's energy needs, the capacity of energy production should be increased. Indonesia government has made a solution by propose 35.000 MW program to increase energy production and electrification ratio in Indonesia. An insulated area where electricity did not reach, has many problem to get electricity such as limited infrastructure, low fuel energy content, and expensive turbine. To solve these problem, multi-vane expander (MVE) can be used to extract the low energy and is cheap. MVE have many advantages such as cheap, easy to manufacture, able to operate with 2 phase, and able to low speed operation. But, the disadvantage of this type of expander is leakage. In this paper, experimental and CFD analysis of MVE are conducted. The experiment generated power of 25.7 watt with isentropic and volumetric efficiency of 11.6% and 11.7% by using operating condition of 1.5 bar, 115.6 °C, 626 rpm, and mass flow rate of 80 kg/h. The CFD model of the expander is created with the same dimension and operating conditions as experimental. The result for isentropic efficiency is inversely proportional with mass flow rate and for volumetric efficiency, power, and expander rotation are directly proportional with mass flow rate.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


Author(s):  
Mirko Baratta ◽  
Andrea E. Catania ◽  
Nicola Rapetto ◽  
Alois Fuerhapter ◽  
Matthias Gerlich ◽  
...  

In the last few years, a significant research effort has been made for developing and enhancing Direct Injection (DI) for compressed natural gas (CNG) engines. Several research projects have been promoted by the European Community (EC) in this field with the objective of finding new solutions for the automotive market and also of encouraging a fruitful knowledge exchange among car manufacturers, suppliers and technical universities. This paper concerns part of the research activity that has been carried out by the Politecnico di Torino, AVL List GmbH and Siemens AG within the EC VII Framework Program (FP) InGAS Collaborative Project (CP), aimed at optimizing the control phase of a new injector for CNG direct injection, paying specific attention to its behavior at small injected-fuel amounts, i.e., small energizing times. The CNG injector which was developed within the research project proved to be suitable to be used in a DI SI engine, featuring a pent-roof combustion chamber head and a bowl in piston, with reference to both homogeneous and stratified charge formation. Fuel flow measurements made by AVL on the four-cylinder engine revealed a good linearity between injection duration and fuel mass-flow rate for injection durations above a reference value. In order to improve the injector characterization at short injection durations, an experimental and numerical activity was designed. More specifically, a multidimensional CFD model of the actual injector geometry was built by Politecnico di Torino, and purposely-designed simulation cases were carried out, in which the needle-lift time-history was defined on the basis of experimental measurements made by Siemens. The numerical model was validated on the basis of experimental data concerning the total injected-fuel amount under different conditions. Then, the model was applied in order to evaluate the dynamic flow characteristic by taking also the inner geometry of the injector valve group into account, so as to establish a correlation to the needle lift measurements done by Siemens for injector characterization. In the paper this dynamic behavior of the injector is analyzed, under actual operating conditions, and its impact on the nozzle injection capability is discussed. The simulation results did not show significant oscillations of the stagnation pressure upstream of the nozzle throat section, and thus the resultant mass-flow rate profile is almost proportional to the needle-lift one. As a consequence, in order to characterize the injector flow behavior in the nonlinear region (short injection duration), the measurement of needle lift is sufficient.


Sign in / Sign up

Export Citation Format

Share Document