Suppression of Short Length-Scale Rotating Stall Inception With Glow Discharge Actuation

Author(s):  
Huu Duc Vo

This paper proposes and investigates the pioneering use of glow discharge (plasma) actuation to suppress short length-scale (spike) rotating stall inception. A single dielectric barrier discharge plasma actuator basically consists of two parallel offset thin electrodes separated by a dielectric material. The application of a high frequency AC voltage across the electrodes results in an induced body force on the flow adjacent to the surface. This simple, robust actuator may provide a practical low-power mean to positively alter the tip clearance flow dynamics responsible for spike stall inception. A computational study is carried out on a low-speed compressor rotor with the implementation of a published plasma actuation model in an established turbomachinery CFD code. The objective is to provide a preliminary assessment of the effectiveness of a casing circumferential plasma actuator, with varying actuator location, input voltage and frequency, in suppressing the two flow criteria associated with the formation of spike disturbances leading to stall. Results show that plasma actuation most effectively suppresses both of these flow criteria when placed near the rotor leading edge and delays the predicted stall point to a lower flow coefficient with minimal power input. The simulations also indicate that the effectiveness of the actuation decreases non-linearly with input voltage and frequency. In addition, results indicate that this technology could perhaps be used for suppression of both short and long-length scale stall inception in axial compressors.

Author(s):  
Huu Duc Vo ◽  
Joshua D. Cameron ◽  
Scott C. Morris

This paper presents a computational assessment of the use of Single Dielectric Barrier Discharge (SDBD), or plasma, actuators for the suppression of short-length scale (spike) stall inception in a transonic axial compressor. Casing plasma actuation has the potential to provide a robust and effective stall suppression device without compromising compressor performance. The objective of this work is to determine the optimum actuator location and actuation strength needed to suppress spike stall inception at transonic speeds without imposing a penalty on compressor performance. This is done through the implementation of an actuator model in a turbomachinery CFD code for simulations of a transonic research compressor rotor passage to measure the effectiveness of casing plasma actuation in delaying the tip clearance flow criteria that are believed to lead to the formation of spike disturbances. Results show that the casing plasma actuator should be positioned near the rotor leading edge so as to optimize the impact on the interface between the incoming and tip clearance flows as well as for practical consideration. Simulations also indicate that the required actuator strength is higher than that of typical SDBD actuators while still remaining within practical achievable limits. These results will form the basis for experimental validation of the concept in the corresponding research compressor rig in the near future.


Author(s):  
M. Inoue ◽  
M. Kuroumaru ◽  
S. Yoshida ◽  
M. Furukawa

The transient processes of rotating stall evolution have been investigated experimentally in a low-speed axial compressor stage with three stator-rotor gaps. The pressure traces at 8 circumferential locations on the casing wall near the rotor leading edge have been analyzed by the wavelet transforms. With the appropriate mother wavelets, the evolution of short and long length-scale disturbances leading to the stall can be captured clearly. Behavior of these disturbances is different depending on the stator-rotor gap. For the large and middle gap, the stall inception is detected by a spiky short length-scale disturbance, and the number of spiky waves increases to generate the high frequency waves. They becomes the short length-scale part-span stall cells at the mild stall for the large gap, while they turn into a big stall cell with growth of a long length-scale disturbance for the middle gap. In the latter case, therefore, the stalling process was identified with ‘high frequency stall inception’. For the small stator-rotor gap, the stalling process is identified with ‘long wave-length stall inception’, and supported the recent computational model for the short wave-length stall inception by showing that closing the rotor-stator gaps suppressed the growth of short length-scale disturbances. From the measurement of the pressure field traces on the casing wall, a hypothesis has been built up that the short length-scale disturbance should result from a separation vortex from a blade surface to reduce circulation. The processes of the stall evolution are discussed on this hypothesis.


2008 ◽  
Vol 130 (1) ◽  
Author(s):  
Huu Duc Vo ◽  
Choon S. Tan ◽  
Edward M. Greitzer

A computational study to define the phenomena that lead to the onset of short length-scale (spike) rotating stall disturbances has been carried out. Based on unsteady simulations, we hypothesize there are two conditions necessary for the formation of spike disturbances, both of which are linked to the tip clearance flow. One is that the interface between the tip clearance and oncoming flows becomes parallel to the leading-edge plane. The second is the initiation of backflow, stemming from the fluid in adjacent passages, at the trailing-edge plane. The two criteria also imply a circumferential length scale for spike disturbances. The hypothesis and scenario developed are consistent with numerical simulations and experimental observations of axial compressor stall inception. A comparison of calculations for multiple blades with those for single passages also allows statements to be made about the utility of single passage computations as a descriptor of compressor stall.


2002 ◽  
Vol 124 (3) ◽  
pp. 376-384 ◽  
Author(s):  
M. Inoue ◽  
M. Kuroumaru ◽  
S. Yoshida ◽  
M. Furukawa

The transient processes of rotating stall evolution have been investigated experimentally in a low-speed axial compressor stage with three stator-rotor gaps. The pressure traces at eight circumferential locations on the casing wall near the rotor leading edge have been analyzed by the wavelet transforms. With the appropriate mother wavelets, the evolution of short and long length-scale disturbances leading to the stall can be captured clearly. Behavior of these disturbances is different depending on the stator-rotor gap. For the large and middle gap, the stall inception is detected by a spiky short length-scale disturbance, and the number of spiky waves increases to generate the high frequency waves. They become the short length-scale part-span stall cells at the mild stall for the large gap, while they turn into a big stall cell with growth of a long length-scale disturbance for the middle gap. In the latter case, therefore, the stalling process was identified with “high-frequency stall inception.” For the small stator-rotor gap, the stalling process is identified with “long wavelength stall inception” and supported the recent computational model for the short wavelength stall inception by showing that closing the rotor-stator gaps suppressed the growth of short length-scale disturbances. From the measurement of the pressure field traces on the casing wall, a hypothesis has been developed that the short length-scale disturbance should result from a separation vortex from a blade surface to reduce circulation. The processes of the stall evolution are discussed on this hypothesis.


1999 ◽  
Vol 121 (4) ◽  
pp. 735-742 ◽  
Author(s):  
D. A. Hoying ◽  
C. S. Tan ◽  
Huu Duc Vo ◽  
E. M. Greitzer

The influence of three-dimensional flow structures within a compressor blade passage has been examined computationally to determine their role in rotating stall inception. The computations displayed a short length-scale (or spike) type of stall inception similar to that seen in experiments; to the authors’ knowledge this is the first time such a feature has been simulated. A central feature observed during the rotating stall inception was the tip clearance vortex moving forward of the blade row leading edge. Vortex kinematic arguments are used to provide a physical explanation of this motion as well as to motivate the conditions for its occurrence. The resulting criterion for this type of stall inception (the movement of the tip clearance vortex forward of the leading edge) depends upon local flow phenomena related to the tip clearance with the implication that for this and possibly other stall mechanisms the flow structure within the blade passages must be addressed to explain the stability of an axial compression system that exhibits such short length-scale disturbances.


Author(s):  
Scott C. Morris ◽  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
G. Scott McNulty ◽  
Aspi Wadia

The performance, efficiency, and stall inception of an axial compressor was investigated experimentally with small levels of rotor centerline offset. The measurements were acquired using a high-speed, single-stage compressor. The rotor was levitated magnetically during operation which allowed precise positioning of the rotor centerline within the circular casing. The offset magnitude used in this study was 0.23% of the rotor tip chord, equivalent to approximately 24% of the nominal gap value. The resulting asymmetry in the tip gap resulted in circumferential and radial variations in the measured stagnation pressure and stagnation temperature downstream of the stage. However, the spatially averaged performance of the compressor was not measurably different from that obtained with a concentric rotor. An array of unsteady (Kulite) pressure transducers was used to investigate the flow field during stall inception. These measurements were recorded during transient throttle movements which quickly decreased the mass flow in the compressor until the onset of rotating stall. A second set of measurements was acquired during quasi-transient throttling starting from a mass flow about 1% larger than the stalling mass flow. In both the symmetric and offset cases the flow breakdown was consistent with spike type inception. The measurements with offset indicated that the asymmetries in the local compressor flow field produced significant changes in the number of short-length scale rotating disturbances observed during throttling to stall. These disturbances appeared in the region of the annulus where the local flow coefficient was lowest and usually decayed upon rotating to the higher flow region. In this way, the addition of very small amounts of rotor offset tended to fix the disturbance generation location in the stationary reference frame. This was in contrast to the symmetric tip clearance case where the location of spike generation appeared stochastic.


Author(s):  
Takahiro Nishioka ◽  
Shuuji Kuroda ◽  
Tadashi Kozu

Inception patterns of rotating stall in a low-speed axial flow fan have been investigated experimentally. Experiments have been carried out at two different stagger angle settings for rotor blades. Pressure and velocity fluctuations were measured to elucidate the features of the stall cells and the stall inception patterns. At the design stagger angle setting for the rotor blades, a short length-scale stall cell known as a “spike” and multiple short length-scale stall cells appear when the slope of pressure-rise characteristic is almost zero. These stall cells grow into a long length-scale stall cell as flow rate decreases. The spike and the multiple short length-scale stall cells do not make the slope of the characteristic positive. However, the long length-scale stall cell induces a full-span stall, and makes the slope of the characteristic positive. At the small stagger angle, a long length-scale disturbance known as a “modal oscillation” is observed first, when the slope of the characteristic is positive. Then the spikes appear together with the modal oscillation as flow rate decreases. The long length-scale stall cell is generated by the spikes without change in the size of the modal oscillation. Suction-tip corner stall occurs in the stator passage near the peak of the characteristic at both the design and the small stagger angle settings. At the design stagger angle, however, the corner stall does not induce the modal oscillation and does not make the characteristic positive. In contrast, the corner stall at the small stagger angle induces the modal oscillation and makes the characteristic positive because it is larger than that at the design stagger angle. It is concluded from these results that the rotating stall inception patterns depend on the rotor stagger angle, which influences blade loading and rotor-stator matching.


Author(s):  
Donald A. Hoying ◽  
Choon S. Tan ◽  
Huu Duc Vo ◽  
Edward M. Greitzer

The influence of three-dimensional flow structures within a compressor blade passage has been examined computationally to determine their role in rotating stall inception. The computations displayed a short length-scale (or spike) type of stall inception similar to that seen in experiments; to the authors’ knowledge this is the first time such a feature has been simulated. A central feature observed during the rotating stall inception was the tip clearance vortex moving forward of the blade row leading edge. Vortex kinematic arguments are used to provide a physical explanation of this motion as well as to motivate the conditions for its occurrence. The resulting criterion for this type of stall inception (which appears generic for axial compressors with tip-critical flow fields) depends upon local flow phenomena related to the tip clearance and it is thus concluded that the flow structure within the blade passages must be addressed to explain the stability of an axial compression system which exhibits such short length-scale disturbances.


AIAA Journal ◽  
2007 ◽  
Vol 45 (7) ◽  
pp. 1596-1605 ◽  
Author(s):  
Jichul Shin ◽  
V. Narayanaswamy ◽  
Laxminarayan L. Raja ◽  
Noel T. Clemens

Sign in / Sign up

Export Citation Format

Share Document