A Numerical Investigation of the Influence of Casing Treatments on the Tip Leakage Flow in a HPC Front Stage

Author(s):  
I. Wilke ◽  
H.-P. Kau

This paper describes the influence of casing treatments on the tip leakage flow and its resulting vortex. The presented results and conclusions are based on steady state numerical simulations of a high pressure compressor stage. Without casing treatments a significant change of behavior of the tip leakage flow can be observed near surge. This change is termed as vortex breakdown and occurs after passing the shock in the blade passage. The simulations indicate the losses in total pressure inside the vortex core as the main reason for the vortex breakdown. These losses mainly depend on the blade loading. Running the compressor stage at high pressure ratios these losses can reach such a high level that the total pressure inside the vortex measured in the rotating system of the rotor falls below the static pressure after the shock. This pressure difference works as a physical barrier for the low energy vortex core and prevents it from reaching the high pressure rotor outlet. Consequently, this blockage must lead to the onset of recirculation zones — the so called vortex breakdown. Different casing treatments have been tested on their ability to delay vortex breakdown and to move the surge line to lower mass flows. Numerical simulations show that configurations with axial slots as well as circumferential grooves weaken or even destroy the characteristic tip leakage vortex and reduce its resulting losses in total pressure. This reduction in losses delays or prevents the onset of vortex breakdown compared to the untreated case explaining the effectiveness of casing treatments. Observations indicate that casing treatments do not interfere with the vortex directly. The key mechanism seems to lay mainly in the interaction with the tip leakage alone. Taking advantage of existing pressure differences in the rotor blade row casing treatments remove tip leakage flow in zones of high pressure and interrupt temporarily the feeding of the vortex. The separated tip leakage reenters the main flow in zones of low pressure again. The way how this tip leakage bypass is realized defines the influence of casing treatments on efficiency and surge line.

Author(s):  
Brian M. T. Tang ◽  
Marko Bacic ◽  
Peter T. Ireland

This paper presents a computational investigation into the impact of cooling air injected through the stationary over-tip turbine casing on overall turbine efficiency. The high work axial flow turbine is representative of the high pressure turbine of a civil aviation turbofan engine. The effect of active modulation of the cooling air is assessed, as well as that of the injection locations. The influence of the through-casing coolant injection on the turbine blade over-tip leakage flow and the associated secondary flow features are examined. Transient (unsteady) sliding mesh simulations of a one turbine stage rotor-stator domain are performed using periodic boundary conditions. Cooling air configurations with a constant total pressure air supply, constant mass flow rate and actively controlled total pressure supply are assessed for a single geometric arrangement of cooling holes. The effects of both the mass flow rate of cooling air and the location of its injection relative to the turbine rotor blade are examined. The results show that all of the assessed cooling configurations provided a benefit to turbine row efficiency of between 0.2 and 0.4 percentage points. The passive and constant mass flow rate configurations reduced the over-tip leakage flow, but did so in an inefficient manner, with decreasing efficiency observed with increasing injection mass flow rate beyond 0.6% of the mainstream flow, despite the over-tip leakage mass flow rate continuing to reduce. By contrast, the active total pressure controlled injection provided a more efficient manner of controlling this leakage flow, as it permitted a redistribution of cooling air, allowing it to be applied in the regions close to the suction side of the blade tip which more directly reduced over-tip leakage flow rates and hence improved efficiency. Cooling air injected close to the pressure side of the rotor blade was less effective at controlling the leakage flow, and was associated with increased aerodynamic loss in the passage vortex.


Author(s):  
Cengiz Camci ◽  
Debashis Dey ◽  
Levent Kavurmacioglu

This paper deals with an experimental investigation of aerodynamic characteristics of full and partial-length squealer rims in a turbine stage. Full and partial-length squealer rims are investigated separately on the pressure side and on the suction side in the “Axial Flow Turbine Research Facility” (AFTRF) of the Pennsylvania State University. The streamwise length of these “partial squealer tips” and their chordwise position are varied to find an optimal aerodynamic tip configuration. The optimal configuration in this cold turbine study is defined as the one that is minimizing the stage exit total pressure defect in the tip vortex dominated zone. A new “channel arrangement” diverting some of the leakage flow into the trailing edge zone is also studied. Current results indicate that the use of “partial squealer rims” in axial flow turbines can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction side partial squealers are aerodynamically superior to the pressure side squealers and the channel arrangement. The suction side partial squealers are capable of reducing the stage exit total pressure defect associated with the tip leakage flow to a significant degree.


Author(s):  
Ali Akturk ◽  
Cengiz Camci

Ducted fans that are popular choices in vertical take-off and landing (VTOL) unmanned aerial vehicles (UAV) offer a higher static thrust/power ratio for a given diameter than open propellers. Although ducted fans provide high performance in many VTOL applications, there are still unresolved problems associated with these systems. Fan rotor tip leakage flow is a significant source of aerodynamic loss for ducted fan VTOL UAVs and adversely affects the general aerodynamic performance of these vehicles. The present study utilized experimental and computational techniques in a 22″ diameter ducted fan test system that has been custom designed and manufactured. Experimental investigation consisted of total pressure measurements using Kiel total pressure probes and real time six-component force and torque measurements. The computational technique used in this study included a 3D Reynolds-Averaged Navier Stokes (RANS) based CFD model of the ducted fan test system. RANS simulations of the flow around rotor blades and duct geometry in the rotating frame of reference provided a comprehensive description of the tip leakage and passage flow. The experimental and computational analysis performed for various tip clearances were utilized in understanding the effect of the tip leakage flow on aerodynamic performance of ducted fans used in VTOL UAVs. The aerodynamic measurements and results of the RANS simulations showed good agreement especially near the tip region.


2021 ◽  
Author(s):  
Subbaramu Shivaramaiah ◽  
Mahesh K. Varpe

Abstract In the present research work, effect of airfoil vortex generator on performance and stability of transonic compressor stage is investigated through CFD simulations. In turbomachines vortex generators are used to energize boundary and generated vortex is made to interact with tip leakage flow and secondary flow vortices formed in rotor and stator blade passage. In the present numerical investigation symmetrical airfoil vortex generator is placed on rotor casing surface close to leading edge, anticipating that vortex generated will be able to disturb tip leakage flow and its interaction with rotor passage core flow. Six different vortex generator configuration are investigated by varying distance between vortex generator trailing edge and rotor leading edge. Particular vortex generator configuration shows maximum improvement of stall margin and operating range by 5.5% and 76.75% respectively. Presence of vortex generator alters flow blockage by modifying flow field in rotor tip region and hence contributes to enhancement of stall margin. As a negative effect, interaction of vortex generator vortices and casing causes surface friction and high entropy generation. As a result compressor stage pressure ratio and efficiency decreases.


Author(s):  
Nikhil M. Rao ◽  
Cengiz Camci

In Part 1 of this paper it was shown that discrete jets issuing from a tip platform trench were successful in reducing the total pressure deficit due to tip leakage flow. The specific tip cooling system used in Part 1 had all four injection locations active. This paper examines the effect of the individual location of the injection hole on the tip leakage flow. The investigation was carried out in a large-scale rotating rig. Total pressure downstream of the rotor exit was measured using a Kulite sensor. The measurements were phase-locked and ensemble averaged over 200 rotor revolutions. The injection holes are located at 61%, 71%, 81%, and 91% blade axial chord, in the tip trench of a single blade with a clearance of 1.40% blade height. Individual injection at 61% and 71% chord reduced the leakage vortex size. Coolant injection at 81% chord was the most successful in reducing the total pressure deficit in the leakage vortex. Injection from 91% chord had no effect on the leakage vortex. Injection from combinations of holes had greater effect in reducing the leakage vortex size and the total pressure deficit associated with the vortex. It can be concluded that the individual jets most likely turn the leakage flow towards the trailing edge. Most of the leakage flow that is responsible for the greatest total pressure deficit occurs around 80% chord.


Author(s):  
Yanhui Wu ◽  
Wuli Chu ◽  
Xingen Lu ◽  
Junqiang Zhu

The current paper reports on investigations with an aim to advance the understanding of the flow field near the casing of a small-scale high-speed axial flow compressor rotor. Steady three dimensional viscous flow calculations are applied to obtain flow fields at various operating conditions. To demonstrate the validity of the computation, the numerical results are first compared with available measured data. Then, the numerically obtained flow fields are analyzed to identify the behavior of tip leakage flow, and the mechanism of blockage generation arising from flow interactions between the tip clearance flow, the blade/casing wall boundary layers, and non-uniform main flow. The current investigation indicates that the “breakdown” of the tip leakage vortex occurs inside the rotor passage at the near stall condition. The vortex “breakdown” results in the low-energy fluid accumulating on the casing wall spreads out remarkably, which causes a sudden growth of the casing wall boundary layer having a large blockage effect. A low-velocity region develops along the tip clearance vortex at the near stall condition due to the vortex “breakdown”. As the mass flow rate is further decreased, this area builds up rapidly and moves upstream. This area prevents incoming flow from passing through the pressure side of the passage and forces the tip leakage flow to spill into the adjacent blade passage from the pressure side at the leading edge. It is found that the tip leakage flow exerts little influence on the development of the blade suction surface boundary layer even at the near stall condition.


Author(s):  
W. Sanz ◽  
M. Kelterer ◽  
R. Pecnik ◽  
A. Marn ◽  
E. Go¨ttlich

The demand of a further increased bypass ratio of aero engines will lead to low pressure turbines with larger diameters which rotate at lower speed. Therefore, it is necessary to guide the flow leaving the high pressure turbine to the low pressure turbine at a larger diameter without any loss generating separation or flow disturbances. Due to costs and weight this intermediate turbine duct has to be as short as possible. This leads to an aggressive (high diffusion) S-shaped duct geometry. In order to investigate the influence of the blade tip gap height of a preceding rotor on such a high-diffusion duct flow a detailed measurement campaign in the Transonic Test Turbine Facility at Graz University of Technology has been performed. A high diffusion intermediate duct is arranged downstream a high-pressure turbine stage providing an exit Mach number of about 0.6 and a swirl angle of −15 degrees (counter swirl). A low-pressure vane row is located at the end of the duct and represents the counter rotating low pressure turbine at larger diameter. At the ASME 2007, results of these investigations were presented for two different tip gap heights of 1.5% span (0.8 mm) and 2.4% span (1.3 mm). In order to better understand the flow phenomena observed in the intermediate duct a detailed numerical study is conducted. The unsteady flow through the whole configuration is simulated for both gap heights as well as for a rotor with zero gap height. The unsteady data are compared at the stage exit and inside the duct to study the flow physics. The calculation of the zero gap height configuration allows to determine the influence of the tip leakage flow of the preceding rotor on the intermediate turbine duct. It turns out that for this aggressive duct the tip leakage flow has a very positive effect on the pressure recovery.


2009 ◽  
Vol 131 (2) ◽  
Author(s):  
Nicolas Gourdain ◽  
Francis Leboeuf

This paper deals with the numerical simulation of technologies to increase the compressor performances. The objective is to extend the stable operating range of an axial compressor stage using passive control devices located in the tip region. First, the behavior of the tip leakage flow is investigated in the compressor without control. The simulation shows an increase in the interaction between the tip leakage flow and the main flow when the mass flow is reduced, a phenomenon responsible for the development of a large flow blockage region at the rotor leading edge. A separation of the rotor suction side boundary layer is also observed at near stall conditions. Then, two approaches are tested in order to control these flows in the tip region. The first one is a casing treatment with nonaxisymmetric slots. The method showed a good ability to control the tip leakage flow but failed to reduce the boundary layer separation on the suction side. However, an increase in the operability was observed but with a penalty for the efficiency. The second approach is a blade treatment that consists of a longitudinal groove built in the tip of each rotor blade. The simulation pointed out that the device is able to control partially all the critical flows with no penalty for the efficiency. Finally, some recommendations for the design of passive treatments are presented.


Author(s):  
R. J. Miller ◽  
R. W. Moss ◽  
R. W. Ainsworth ◽  
N. W. Harvey

This paper describes both the migration and dissipation of flow phenomena downstream of a transonic high-pressure turbine stage. The geometry of the HP stage exit duct considered is a swan-necked diffuser similar to those likely to be used in future engine designs. The paper contains results both from an experimental programme in a turbine test facility and from numerical predictions. Experimental data was acquired using three fast-response aerodynamic probes capable of measuring Mach number, whirl angle, pitch angle, total pressure and static pressure. The probes were used to make time-resolved area traverses at two axial locations downstream of the rotor trailing edge. A 3D time-unsteady viscous Navier-Stokes solver was used for the numerical predictions. The unsteady exit flow from a turbine stage is formed from rotor-dependent phenomena (such as the rotor wake, the rotor trailing edge recompression shock, the tip-leakage flow and the hub secondary flow) and vane-rotor interaction dependant phenomena. This paper describes the time-resolved behaviour and three-dimensional migration paths of both of these phenomena as they convect downstream. It is shown that the inlet flow to a downstream vane is dominated by two corotating vortices, the first caused by the rotor tip-leakage flow and the second by the rotor hub secondary flow. At the inlet plane of the downstream vane the wake is extremely weak and the radial pressure gradient is shown to have caused the majority of the high loss wake fluid to be located between the mid-height of the passage and the casing wall. The structure of the flow indicates that between a high pressure stage and a downstream vane simple two-dimensional blade row interaction does not occur. The results presented in this paper indicate that the presence of an upstream stage is likely to significantly alter the structure of the secondary flow within a downstream vane. The paper also shows that vane-rotor interaction within the upstream stage causes a 10° circumferential variation in the inlet flow angle of the 2nd stage vane.


Author(s):  
Jin-sol Jung ◽  
Okey Kwon ◽  
Changmin Son

The flow leaking over the tip of a high pressure turbine blade generates significant aerodynamic losses as it mixes with the mainstream flow. This study investigates the effect of blade tip geometries on turbine performance with both steady RANS and unsteady URANS analyses. Five different squealer geometries for a high pressure turbine blade have been examined: squealer on pressure side, squealer on suction side, cavity squealer, cavity squealer with pressure side cutback, and cavity squealer with suction side cutback. With the case of the cavity squealer, three different squealer wall thickness are investigated for the wall thickness (w) of 1x, 2x and 4x of the tip gap (G). The unsteady flow analyses using CFX have been conducted to investigate unsteady characteristics of the tip leakage flow and its influence on turbine performances. Through the comparison between URANS analyses, detailed vortex and wake structures are identified and studied at different fidelities. It is found that the over tip leakage flow loss is affected by the tip suction side geometry rather than that of the pressure side geometry. The unsteady results have contributed to resolve the fundamentals of vortex structures and aerodynamic loss mechanisms in a high pressure turbine stage.