The Model Steam Turbine: More Details About the Heat Recovery Steam Generator Evaluating Method in a Combined Cycle Plant

Author(s):  
Dietmar Schmidt ◽  
Michail Arnold

Turnkey and thermal island supply scopes present turbine suppliers with a perfect way to sell their rotating products. The popularity of these plant configurations, along with the recent availability of more holistic test codes, has led to the need for an accurate and reasonable method of determining the thermal performance of the externally-purchased HRSG component. To assess a multiple pressure HRSG, it is advantageous and convenient to have one single criterion for the evaluation of performance, especially when this criterion provides for the compensation of the different outlet energy streams. The so-called Model Steam Turbine method of HRSG evaluation was developed for these reasons. The result of the calculation, a lone performance criterion, is the shaft power of the fictitious Model Steam Turbine.

Author(s):  
Dietmar Schmidt ◽  
Terrence Sullivan

Turnkey and thermal island supply scopes present turbine manufacturers with a perfect way to sell their rotating products. The popularity of these plant configurations, along with the recent availability of more holistic test codes, has led to the need for an accurate and reasonable method of determining the thermal performance of the externally-purchased HRSG component. To assess a multiple pressure HRSG, it is advantageous and convenient to have one single criterion for the evaluation of performance, especially when this criterion provides for the compensation of the different outlet energy streams. The so-called Model Steam Turbine method of HRSG evaluation was developed for these reasons. The result of the calculation, a lone performance criterion, is the shaft power of the fictitious Model Steam Turbine. In this paper we will detail the components of the Model Steam Turbine calculation and explore the merits of this method. Some thoughts on performance corrections are also presented.


1997 ◽  
Vol 119 (4) ◽  
pp. 250-256 ◽  
Author(s):  
H. Jin ◽  
M. Ishida ◽  
M. Kobayashi ◽  
M. Nunokawa

Two operating advanced power plants, a supercritical steam plant and a gas-steam turbine combined cycle, have been analyzed using a methodology of graphical exergy analysis (EUDs). The comparison of two plants, which may provide the detailed information on internal phenomena, points out several inefficient segments in the combined cycle plant: higher exergy loss caused by mixing in the combustor, higher exergy waste from the heat recovery steam generator, and higher exergy loss by inefficiency in the power section, especially in the steam turbine. On the basis of these fundamental features of each plant, we recommend several schemes for improving the thermal efficiency of current advanced power plants.


Author(s):  
Donald A. Kolp ◽  
Charles E. Levey

Zorlu Enerji needed 35 MW of reliable power at a stable frequency to maintain constant speed on the spindles producing thread at its parent company’s textile plant in Bursa, Turkey. In December of 1996, Zorlu selected an LM2500+ combined cycle plant to fill its power-generating requirements. The LM2500+ has output of 26,810 KW at a heat rate of 9,735 Kj/Kwh. The combined cycle plant has an output of 35,165 KW and a heat rate of 7,428 Kj/Kwh. The plant operates in the simple cycle mode utilizing the LM2500+ and a bypass stack and in combined cycle mode using the 2-pressure heat recovery steam generator and single admission, 9.5 MW condensing steam turbine. The generator is driven through a clutch by the steam turbine from the exciter end and by the gas turbine from the opposing end. The primary fuel for the plant is natural gas; the backup fuel is naphtha. Utilizing a load bank, the plant is capable of accepting a 12 MW load loss when the utility breaker trips open; it can sustain this loss while maintaining frequency within 1% on the mill load. The frequency stabilizing capability prevents overspeeding of the spindles, breakage of thousands of strands of thread and a costly shutdown of the mill. A description of the equipment, operation and performance illustrates the unique features of this versatile, compact and efficient generating unit.


Author(s):  
Mohammad R. Shahnazari ◽  
Abbas Abbassi

A common repowering option is converting a fossil-fired steam unit to a gas-fired combined-cycle plant by addition of a combustion turbine and a Heat Recovery Steam Generator. In this approach the existing steam turbine and related auxiliaries are typically retained and some plant modification is applied. This paper intends to study this option for two old power plants. In this study the HRSGs are modeled, designed and their costs are estimated. Total generating cost for both plants are calculated in order to show whether or not the final cost is competitive with the cost of a new combined cycle unit.


2020 ◽  
Vol 8 (9) ◽  
pp. 726
Author(s):  
Wahyu Nirbito ◽  
Muhammad Arif Budiyanto ◽  
Robby Muliadi

This study explains the performance analysis of a propulsion system engine of an LNG tanker using a combined cycle whose components are gas turbine, steam turbine, and heat recovery steam generator. The researches are to determine the total resistance of an LNG tanker with a capacity of 125,000 m3 by using the Maxsurf Resistance 20 software, as well as to design the propulsion system to meet the required power from the resistance by using the Cycle-Tempo 5.0 software. The simulation results indicate a maximum power of the system of about 28,122.23 kW with a fuel consumption of about 1.173 kg/s and a system efficiency of about 48.49% in fully loaded conditions. The ship speed can reach up to 20.67 knots.


1979 ◽  
Author(s):  
L. F. Fougere ◽  
H. G. Stewart ◽  
J. Bell

Citizens Utilities Company’s Kauai Electric Division is the electric utility on the Island of Kauai, fourth largest and westernmost as well as northernmost of the Hawaiian Islands. As a result of growing load requirements, additional generating capacity was required that would afford a high level of reliability and operating flexibility and good fuel economy at reasonable capital investment. To meet these requirements, a combined cycle arrangement was completed in 1978 utilizing one existing gas turbine-generator and one new gas turbine-generator, both exhausting to a new heat recovery steam generator which supplies steam to an existing steam turbine-generator. Damper controlled ducting directs exhaust gas from either gas turbine, one at a time, through the heat recovery steam generator. The existing oil-fired steam boiler remains available to power the steam turbine-generator independently or in parallel with the heat recovery steam generator. The gas turbines can operate either in simple cycle as peaking units or in combined cycle, one at a time, as base load units. This arrangement provides excellent operating reliability and flexibility, and the most favorable economics of all generating arrangements for the service required.


2013 ◽  
Vol 34 (4) ◽  
pp. 215-233 ◽  
Author(s):  
Janusz Kotowicz ◽  
Marcin Job

Abstract This paper presents a gas turbine combined cycle plant with oxy-combustion and carbon dioxide capture. A gas turbine part of the unit with the operating parameters is presented. The methodology and results of optimization by the means of a genetic algorithm for the steam parts in three variants of the plant are shown. The variants of the plant differ by the heat recovery steam generator (HRSG) construction: the singlepressure HRSG (1P), the double-pressure HRSG with reheating (2PR), and the triple-pressure HRSG with reheating (3PR). For obtained results in all variants an economic evaluation was performed. The break-even prices of electricity were determined and the sensitivity analysis to the most significant economic factors were performed.


2007 ◽  
Vol 11 (4) ◽  
pp. 143-156 ◽  
Author(s):  
Kumar Ravi ◽  
Krishna Rama ◽  
Rama Sita

Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.


Author(s):  
Bruce Kelly ◽  
Ulf Herrmann ◽  
Mary Jane Hale

Abstract The integrated solar plant concept was initially proposed by Luz Solar International [1] as a means of integrating a parabolic trough solar plant with modern combined cycle power plants. An integrated plant consists of a conventional combined cycle plant, a solar collector field, and a solar steam generator. During sunny periods, feedwater is withdrawn from the combined cycle plant heat recovery steam generator, and converted to saturated steam in the solar steam generator. The saturated steam is returned to the heat recovery steam generator, and the combined fossil and solar steam flows are superheated in the heat recovery steam generator. The increased steam flow rate provides an increase in the output of the Rankine cycle. During cloudy periods and at night, the integrated plant operates as a conventional combined cycle facility. Two studies on integrated plant designs using a General Electric Frame 7(FA) gas turbine and a three pressure heat recovery steam generator are currently being conducted by the authors. Preliminary results include the following items: 1) the most efficient use of solar thermal energy is the production of high pressure saturated steam for addition to the heat recovery steam generator; 2) the quantity of high pressure steam generation duty which can be transferred from the heat recovery steam generator to the solar steam generator is limited; thus, the maximum practical solar contribution is also reasonably well defined; 3) small annual solar thermal contributions to an integrated plant can be converted to electric energy at a higher efficiency than a solar-only parabolic trough plant, and can also raise the overall thermal-to-electric conversion efficiency in the Rankine cycle; and 4) annual solar contributions up to 12 percent in an integrated plant should offer economic advantages over a conventional solar-only parabolic trough power plant.


Author(s):  
A. I. Zwebek ◽  
P. Pilidis

This paper investigates the possibility of applying a new technique called Gas/Steam Path Analysis (GSPA), that is based on the principles of Gas Path Analysis (GPA), to gas as well as steam turbine plants (as one unit) that are main parts of a combined cycle power plant by way of simulation. In order to facilitate this investigation two pieces of software were developed at Cranfield University. With this technique, it was possible to monitor the major components of the combined cycle, and hence predict the faults that may occur within the cycle beforehand. Faults looked at were, fouling and erosion of gas and steam turbine units, heat recovery steam generator degradation (scaling and/or ashe deposition), and condenser degradation. The obtained results from GSPA calculations of the cases investigated showed that “GSPA” technique can be equally applied to either gas turbine cycle, steam turbine cycle, or to the combination of the two in a form of combined cycle. The procedure, assumptions made, and the results obtained are presented and discussed herein.