Mist/Steam Heat Transfer With Jet Impingement Onto a Concave Surface

Author(s):  
Xianchang Li ◽  
J. Leo Gaddis ◽  
Ting Wang

Internal mist/steam blade cooling technology has been considered for the future generation of Advanced Turbine Systems (ATS). Fine water droplets about 5 μm were carried by steam through a single slot jet onto a concave heated target surface in a confined channel to simulate inner surface cooling at the leading edge of a turbine blade. Experiments covered Reynolds numbers from 7,500 to 22,000 and heat fluxes from 3 to 21 kW/m2. The general level of heat transfer coefficient is, within experimental uncertainty, the same as the flat surface at comparable conditions. The experimental results indicate that the cooling is enhanced significantly near the stagnation point by the mist, decreasing downstream. Unlike impingement onto a flat plate the enhancement continues at all points downstream. Similar to the results of the flat surface, the heat transfer enhancement declines at higher heat fluxes. Up to 200% heat transfer enhancement at the stagnation point was achieved by injecting approximately 0.5% of mist.

2003 ◽  
Vol 125 (3) ◽  
pp. 438-446 ◽  
Author(s):  
Xianchang Li ◽  
J. Leo Gaddis ◽  
Ting Wang

Internal mist/steam blade cooling technology is proposed for the future generation of Advanced Turbine Systems (ATS). Fine water droplets about 5 μm were carried by steam through a slot jet onto a concave heated surface in a confined channel to simulate inner surface cooling at the leading edge of a turbine blade. Experiments covered Reynolds numbers from 7500 to 22,000 and heat fluxes from 3 to 21 kW/m2. Results indicate that the cooling is enhanced significantly near the stagnation point by the mist, decreasing downstream. Unlike impingement onto a flat target where the enhancement vanished at six jet diameters downstream, the cooling enhancement over a concave surface prevails at all points downstream. Similar to the results of the flat surface, the cooling enhancement declines at higher heat fluxes. Up to 200 % cooling enhancement at the stagnation point was achieved by injecting approximately 0.5 % of mist.


Author(s):  
J.-J. Hwang ◽  
C.-S. Cheng ◽  
Y.-P. Tsia

An experimental study has been performed to measure local heat transfer coefficients and static well pressure drops in leading-edge triangular ducts cooled by wall/impinged jets. Coolant provided by an array of equally spaced wall jets is aimed at the leading-edge apex and exits from the radial outlet. Detailed heat transfer coefficients are measured for the two walls forming the apex using transient liquid crystal technique. Secondary-flow structures are visualized to realize the mechanism of heat transfer enhancement by wall/impinged jets. Three right-triangular ducts of the same altitude and different apex angles of β = 30 deg (Duct A), 45 deg (Duct B) and 60 deg (Duct C) are tested for various jet Reynolds numbers (3000≦Rej≦12600) and jet spacings (s/d = 3.0 and 6.0). Results show that an increase in Rej increases the heat transfer on both walls. Local heat transfer on both walls gradually decreases downstream due to the crossflow effect. At the same Rej, the Duct C has the highest wall-averaged heat transfer because of the highest jet center velocity as well as the smallest jet inclined angle. Moreover, the distribution of static pressure drop based on the local through flow rate in the present triangular duct is similar to that that of developing straight pipe flows. Average jet Nusselt numbers on the both walls have been correlated with jet Reynolds number for three different duct shapes.


2017 ◽  
Vol 21 (1 Part A) ◽  
pp. 279-288 ◽  
Author(s):  
Shuxia Qiu ◽  
Peng Xu ◽  
Liping Geng ◽  
Arun Mujumdar ◽  
Zhouting Jiang ◽  
...  

Air jet impingement is one of the effective cooling techniques employed in micro-electronic industry. To enhance the heat transfer performance, a cooling system with air jet impingement on a finned heat sink is evaluated via the computational fluid dynamics method. A two-dimensional confined slot air impinging on a finned flat plate is modeled. The numerical model is validated by comparison of the computed Nusselt number distribution on the impingement target with published experimental results. The flow characteristics and heat transfer performance of jet impingement on both of smooth and finned heat sinks are compared. It is observed that jet impingement over finned target plate improves the cooling performance significantly. A dimensionless heat transfer enhancement factor is introduced to quantify the effect of jet flow Reynolds number on the finned surface. The effect of rectangular fin dimensions on impingement heat transfer rate is discussed in order to optimize the cooling system. Also, the computed flow and thermal fields of the air impingement system are examined to explore the physical mechanisms for heat transfer enhancement.


Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 813 ◽  
Author(s):  
Parkpoom Sriromreun ◽  
Paranee Sriromreun

This research was aimed at studying the numerical and experimental characteristics of the air flow impinging on a dimpled surface. Heat transfer enhancement between a hot surface and the air is supposed to be obtained from a dimple effect. In the experiment, 15 types of test plate were investigated at different distances between the jet and test plate (B), dimple diameter (d) and dimple distance (Er and Eθ). The testing fluid was air presented in an impinging jet flowing at Re = 1500 to 14,600. A comparison of the heat transfer coefficient was performed between the jet impingement on the dimpled surface and the flat plate. The velocity vector and the temperature contour showed the different air flow characteristics from different test plates. The highest thermal enhancement factor (TEF) was observed under the conditions of B = 2 d, d = 1 cm, Er= 2 d, Eθ = 1.5 d and Re = 1500. This TEF was obtained from the dimpled surface and was 5.5 times higher than that observed in the flat plate.