Modeling Air Jet Penetration Into Gas-Particle Suspension Cross Flow

Author(s):  
Ville Tossavainen ◽  
Reijo Karvinen ◽  
Matti Ylitalo

In the paper, numerical modeling of air jet mixing in gas–particle suspension is discussed. The theory on which the modeling is based on is presented and to get a reliable opinion of its capability as a boiler design tool, the results are compared with those obtained experimentally in a cold pilot boiler. Based on the research on the pilot unit, the modeling seems to give reliable results. The modeling has also been applied to a full-scale boiler.

1992 ◽  
Vol 26 (9-11) ◽  
pp. 2109-2112
Author(s):  
J. G. Cleary ◽  
T. J. Boehm ◽  
R. J. Geary

Schoeller Technical Papers, Inc. (Schoeller), which manufactures photographic and other specialty papers, is located in Pulaski, New York. The wastewater treatment system consists of a primary clarifier and two settling lagoons. Secondary treatment using a biotower was proposed to meet the new New York State Pollutant Discharge Elimination System (SPDES) discharge limits for BOD and TSS. The effluent from each basin is discharged directly to the Salmon River, at an approximate average flow of 1.6 million gallons/day (mgd). A biotower pilot study was performed to evaluate the suitability of a biotower treatment process for treating the total effluent from Schoeller's facility. The pilot study was used to select the media for the full-scale biotower and to confirm the design loading for the full-scale biotower, which proceeded in parallel with the pilot study due to the schedule constraints. Two pilot systems were operated to compare a conventional cross-flow and vertical media. Test data were collected to evaluate the performance of each pilot treatment system at a range of loading conditions and to develop the design loading information for the full-scale plant. The pilot units were operated for a period of 10 months. BOD concentrations to the pilot units averaged 58 mg/l with a peak of 210 mg/l. Approximately 80% of the BOD was soluble. BOD loadings averaged 21 lb BOD/day/1,000 cubic feet with a peak of 77 lb BOD/day/1,000 cubic feet. Both pilot units achieved excellent BOD removals exceeding 75%, with average effluent soluble BOD concentration less than 10 mg/l and average effluent TSS concentrations of 12 mg/l. The two media achieved comparable performance throughout most of the pilot study.


Author(s):  
Dhyanjyoti Deka ◽  
Paul R. Hays ◽  
Kamaldev Raghavan ◽  
Mike Campbell

VIVA is a vortex induced vibration (VIV) analysis software that to date has not been widely used as a design tool in the offshore oil and gas industry. VIVA employs a hydrodynamic database that has been benchmarked and calibrated against test data [1]. It offers relatively few input variables reducing the risk of user induced variability of results [2]. In addition to cross flow current induced standing wave vibration, VIVA has the capability of predicting traveling waves on a subsea riser, or a combination of standing and traveling waves. Riser boundary conditions including fixed, pinned, flex joint or SCR seabed interaction can be modeled using springs and dashpots. VIVA calculates riser natural frequencies and mode shapes and also has the flexibility to import external modal solutions. In this paper, the applicability of VIVA for the design of straked steel catenary risers (SCR) and top tensioned risers (TTR) is explored. The use of linear and rotational springs provided by VIVA to model SCR soil interaction and flex joint articulation is evaluated. Comparisons of the VIV fatigue damage output with internal and external modal solution is presented in this paper. This paper includes validation of the VIVA generated modal solution by comparing the modal frequencies and curvatures against a finite element (FE) model of the risers. Fatigue life is calculated using long term Gulf of Mexico (GoM) currents and is compared against the industry standard software SHEAR7. Three different lift curve selections in SHEAR7 are used for this comparison. The differences in riser response prediction by the two software tools are discussed in detail. The sensitivity of the VIVA predicted riser response to the absence of VIV suppression devices is presented in this paper. The riser VIV response with and without external FE generated modal input is compared and the relative merits of the two modeling approaches are discussed. Finally, the recommended approach for VIVA usage for SCR and TTR design is given.


1986 ◽  
Vol 2 (4) ◽  
pp. 354-360 ◽  
Author(s):  
A. R. Karagozian ◽  
T. T. Nguyen ◽  
C. N. Kim
Keyword(s):  

1992 ◽  
Vol 114 (1) ◽  
pp. 46-54 ◽  
Author(s):  
P. J. Vermeulen ◽  
P. Grabinski ◽  
V. Ramesh

The mixing of an acoustically pulsed air jet with a confined hot crossflow has been assessed by temperature profile measurements. These novel experiments were designed to examine the effects of acoustic driver power and Strouhal number on jet structure, penetration, and mixing. The results showed that excitation produced strong changes in the measured temperature profiles. This resulted in significant increases in mixing zone size, penetration (at least 100 percent increase), and mixing, and the length to achieve a given mixed state was shortened by at least 70 percent. There was strong modification to the jet-wake region. The increase in jet penetration and mixing was saturating near 90 W, the largest driving power tested. The jet response as determined by penetration and mixing was optimum at a Strouhal number of 0.27. Overall, pulsating the jet flow significantly improved the jet mixing processes in a controllable manner.


Author(s):  
M. A. Gadalla ◽  
M. A. R. Sharif

Abstract A mathematical/empirical model compatible with the jet mixing theory for predicting the flow field properties, flame envelope, temperature distribution, and flame heights around a free vertical axi-symmetric turbulent diffusion flame has been developed. The model considers the effects of buoyancy force and the relative angle between the reactant jets. The flames are issued from a burner which consists of a central air jet and an annular fuel (commercial butane) jet. The annular jet is issued either vertically or at an angle to the flame axis. Experiments were performed earlier to measure the temperature distribution and concentration of carbon dioxide and oxygen in such flames. Three angular positions of the annular fuel jet and nine burner geometries were investigated. The model predictions in similar configurations are found to be in fair agreement with the experimental data.


Author(s):  
M. A. R. Sharif ◽  
M. A. Gadalla

Abstract Isothermal turbulent mixing of an axisymmetric primary air jet with a low velocity annular secondary air stream inside a constant diameter cylindrical enclosure is predicted. The flow domain from the inlet to the fully developed downstream locations is considered. The predicted flow field properties include the mean velocity and pressure and the Reynolds stresses. Different velocity and diameter ratios between the primary and the secondary jets have been investigated to characterize the flow in terms of these parameters. A bounded stream-wise differencing scheme is used to minimize numerical diffusion and oscillation errors. Predictions are compared with available experimental data to back up numerical findings.


Author(s):  
Halvor Lie ◽  
Henning Braaten ◽  
Jamison Szwalek ◽  
Massimiliano Russo ◽  
Rolf Baarholm

For deep-water riser systems, Vortex Induced Vibrations (VIV) may cause significant fatigue damage. It appears that the knowledge gap of this phenomenon is considerable and this has caused a high level of research activity over the last decades. Small scale model tests are often used to investigate VIV behaviour. However, one substantial uncertainty in applying such results is scaling effects, i.e. differences in VIV response in full scale flow and small scale flow. To (partly) overcome this obstacle, a new innovative VIV test rig was designed and built at MARINTEK to test a rigid full scale riser model. The rigid riser model is mounted vertically and can either be elastically mounted or be given a forced motion. In the present version, the cylinder can only move in the cross-flow (CF) direction and is restricted in the in-line (IL) direction. The paper reports results from a drilling riser VIV experiment where the new rest rig has been used. The overall objective of the work is to study possible VIV suppression to improve operability of retrievable riser systems with auxiliary lines by adding riser fins. These fins are normally used as devices for protection of the auxiliary lines. The test program has recently been completed and analysis is an on-going activity. However, some results can be reported at this stage and more results are planned to be published. A bare riser model was used in a Reynolds number (Rn) scaling effect study. The riser model was elastically mounted and towed over a reduced velocity range around 4 – 10 in two different Rn ranges, 75 000 – 192 000 (subcritical regime) and 347 000 – 553 000 (critical regime). The difference in the displacement amplitude to diameter ratio, A/D, is found to be significant. The elastically mounted riser was also towed with various drilling riser configurations in order to study VIV/galloping responses. One configuration included a slick joint riser model with 6 kill & choke lines; another has added riser fins too. The riser model is based on a specific drilling riser and the kill and choke lines have various diameters and have a non-symmetrical layout. The various riser configurations have also been used in forced motion tests where the towed model has been given a sinusoidal CF motion. Forces have been measured. Determination of the force coefficients is still in progress and is planned to be reported later. Scaling effects appear to be a significant uncertainty and further research on the subject is recommended. The slick joint drilling riser configuration generally increased the displacements compared to displacements of the bare riser model. The drilling riser configuration with protection fins, kill and choke lines generally reduced the displacements compared to displacements of the bare riser model. For both riser systems, tests showed that the response is sensitive to the heading of the current.


Author(s):  
Mikhail Vodiannikov ◽  
Galina Kashevarova ◽  
Danil Starobogatov

This paper presents the results of numerical modeling and full-scale experiments of the failure process of a glued laminated timber beam with rigid joint in the middle. All the connecting parts are made of carbon fiber. The structural analysis is done with the finite element method (ANSYS software). The nonlinear problem was solved. The contact interaction of the structural elements in the process of deformation and fracture, as well as orthotropy of the wood, the transversely isotropic properties of the plates, and the real diagrams of the deformation of carbon fiber dowel pins were taken into account. The influence of the structural parameters of the joint on the position of the most loaded dowel pin in the joint and the bearing capacity of the general structure are investigated. To verify the structural analysis results, field tests were carried out before destruction by a stepwise increasing load on a personally designed stand. The destruction of the structure occurred according to the forecast of the numerical model as a result of the mutual slip of the glued wood layers and the destruction of the polymer matrix of the glued dowel pins with the beginning of the formation of plastic joints and the formation of cracks in the wood at the junction.


2019 ◽  
Vol 213 ◽  
pp. 299-307 ◽  
Author(s):  
Jacek Chróścielewski ◽  
Tomasz Ferenc ◽  
Tomasz Mikulski ◽  
Mikołaj Miśkiewicz ◽  
Łukasz Pyrzowski

Sign in / Sign up

Export Citation Format

Share Document