Heat Transfer Coefficient and Pressure Drop of R410A During Evaporation Inside Aluminum Multiport Minichannels

Author(s):  
Chien Nguyen ◽  
Vu Pham ◽  
Choi Kwang-Il ◽  
Oh Jong-Taek

Micro and minichannel are progressively used in heat exchangers nowadays. The application of these heat exchanger types in refrigeration and air conditioning fields show various advantages such as high efficiency, low air side pressure, reducing refrigerant charge and the compactness size. The aim of this study is to investigate the two phase flow heat transfer coefficient and pressure drop of R410A during evaporation. The experimental data were observed in aluminum channel with the hydraulic diameters of 1.14 and 1.16 mm, mass fluxes of 50–150 kW/m2s heat fluxes of 3–6 kW/m2, saturation temperature of 6°C and vapor quality from 0.1 to 0.9. The effect of mass flux, heat flux, and hydraulic diameter on heat transfer coefficient and pressure drop were analyzed. The database was compared with numerous well-known heat transfer coefficient and pressure drop correlations. Finally, a modify heat transfer coefficient correlation was developed that showed a good prediction against the database.

2016 ◽  
Vol 819 ◽  
pp. 94-100
Author(s):  
Pham Quang Vu ◽  
Nguyen Ba Chien ◽  
Oh Jong Taek

Condensation heat transfer has been evaluated experimentally on the tube side of three different circular tubes with inner diameter of 6.2, 7.5 and 9.2mm, respectively. Two-phase fluid flow conditions include mass fluxes from 200 to 320kg/m2s, qualities between 0.1 to 0.9, and heat flus range of 5 to 20kW/m2 at a fixed saturation temperature of 48°C. Results showed that the average heat transfer coefficient increased with the increase of vapor quality, mass flux and heat flux, but decreased with inner diameter. The experiment results are compared with the existing heat transfer coefficient correlations, and a new correlation is developed with good prediction.


Author(s):  
Raphael Mandel ◽  
Amir Shooshtari ◽  
Serguei Dessiatoun ◽  
Michael Ohadi

Manifold microchannels utilize a system of manifolds to divide long microchannels into an array of parallel ones, resulting in reduced flow length and more localized liquid feeding. Reducing flow length is desirable because it enables the simultaneous enhancement of heat transfer rate and reduction of pressure drop. Furthermore, localized feeding reduces potential for localized dryout, increasing the operational heat flux. Because of the failure of the available conventional heat transfer correlations to predict the thermal performance of manifold microchannels operating in two phase mode, a “streamline” model was created. The heat transfer surface area was divided into parallel, non-interacting streamlines, and the quality, void fraction, film thickness, heat transfer coefficient, heat flux, and pressure drop was calculated sequentially along the streamline. The mass flow rate through each streamline was adjusted in order to obtain the specified pressure drop, and the value of this pressure drop was adjusted in order to obtain the desired microchannel mass flux. Finally, the average wall heat transfer coefficient was calculated, and temperature profile in the fin was adjusted to correspond with the analytical 1-D temperature distribution of a thin fin with an average wall heat transfer coefficient and specified base superheat. The average wall heat transfer coefficients predicted by the model was then compared to the available experimental data with sufficiently good agreement with a wide variety of geometries and working fluids at low mass fluxes.


2001 ◽  
Author(s):  
S. I. Haider ◽  
Yogendra K. Joshi ◽  
Wataru Nakayama

Abstract The study presents a model for the two-phase flow and heat transfer in the closed loop, two-phase thermosyphon (CLTPT) involving co-current natural circulation. Most available models deal with two-phase thermosyphons with counter-current circulation within a closed, vertical, wickless heat pipe. The present research focuses on CLTPTs for electronics cooling that face more complex two-phase flow patterns than the vertical heat pipes, due to closed loop geometry and smaller tube size. The present model is based on mass, momentum, and energy balances in the evaporator, rising tube, condenser, and the falling tube. The homogeneous two-phase flow model is used to evaluate the friction pressure drop of the two-phase flow imposed by the available gravitational head through the loop. The saturation temperature dictates both the chip temperature and the condenser heat rejection capacity. Thermodynamic constraints are applied to model the saturation temperature, which also depends upon the local heat transfer coefficient and the two-phase flow patterns inside the condenser. The boiling characteristics of the enhanced structure are used to predict the chip temperature. The model is compared with experimental data for dielectric working fluid PF-5060 and is in general agreement with the observed trends. The degradation of condensation heat transfer coefficient due to diminished vapor convective effects, and the presence of subcooled liquid in the condenser are expected to cause higher thermal resistance at low heat fluxes. The local condensation heat transfer coefficient is a major area of uncertainty.


Author(s):  
Ayman Megahed ◽  
Ibrahim Hassan ◽  
Tariq Ahmad

The present study focuses on the experimental investigation of boiling heat transfer characteristics and pressure drop in a silicon microchannel heat sink. The microchannel heat sink consists of a rectangular silicon chip in which 45 rectangular microchannels were chemically etched with a depth of 295 μm, width of 254 μm, and a length of 16 mm. Un-encapsulated Thermochromic liquid Crystals (TLC) are used in the present work to enable nonintrusive and high spatial resolution temperature measurements. This measuring technique is used to provide accurate full and local surface-temperature and heat transfer coefficient measurements. Experiments are carried out for mass velocities ranging between 290 to 457 kg/m2.s and heat fluxes from 6.04 to 13.06 W/cm2 using FC-72 as the working fluid. Experimental results show that the pressure drop increases as the exit quality and the flow rate increase. High values of heat transfer coefficient can be obtained at low exit quality (xe < 0.2). However, the heat transfer coefficient decreases sharply and remains almost constant as the quality increases for an exit quality higher than 0.2.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Santosh Krishnamurthy ◽  
Yoav Peles

Flow boiling of 1-methoxyheptafluoropropane (HFE 7000) in 222 μm hydraulic diameter channels containing a single row of 24 inline 100 μm pin fins was studied for mass fluxes from 350 kg/m2 s to 827 kg/m2 s and wall heat fluxes from 10 W/cm2 to 110 W/cm2. Flow visualization revealed the existence of isolated bubbles, bubbles interacting, multiple flow, and annular flow. The observed flow patterns were mapped as a function of the boiling number and the normalized axial distance. The local heat transfer coefficient during subcooled boiling was measured and found to be considerably higher than the corresponding single-phase flow. Furthermore, a thermal performance evaluation comparison with a plain microchannel revealed that the presence of pin fins considerably enhanced the heat transfer coefficient.


Author(s):  
S. V. Sridhar ◽  
R. Karuppasamy ◽  
G. D. Sivakumar

Abstract In this investigation, the performance of the shell and tube heat exchanger operated with tin nanoparticles-water (SnO2-W) and silver nanoparticles-water (Ag-W) nanofluids was experimentally analyzed. SnO2-W and Ag-W nanofluids were prepared without any surface medication of nanoparticles. The effects of volume concentrations of nanoparticles on thermal conductivity, viscosity, heat transfer coefficient, fiction factor, Nusselt number, and pressure drop were analyzed. The results showed that thermal conductivity of nanofluids increased by 29% and 39% while adding 0.1 wt% of SnO2 and Ag nanoparticles, respectively, due to the unique intrinsic property of the nanoparticles. Further, the convective heat transfer coefficient was enhanced because of improvement of thermal conductivity of the two phase mixture and friction factor increased due to the increases of viscosity and density of nanofluids. Moreover, Ag nanofluid showed superior pressure drop compared to SnO2 nanofluid owing to the improvement of thermophysical properties of nanofluid.


Author(s):  
Pega Hrnjak ◽  
Seongho Kim

Flow boiling heat transfer characteristics of CO2 with and without oil were investigated experimentally in horizontal smooth and enhanced tubes with an inner diameter of 11.2 mm. The visualization of flow pattern provides a detailed attributes of the nucleate and the convective boiling heat transfer. In order to investigate the effect of the miscible oil on the heat transfer of CO2, POE (polyolester) RENSIO C85E oil is added to give an oil circulation rate (OCR) between 0.5% and 2%. Results are compared with those of pure CO2. The experimental conditions include evaporation temperatures of −15 °C, mass fluxes from 40 to 200 kg/m2 s, heat fluxes from 0.5 to 10 kW/m2, and vapor qualities from 0.1 to 0.8. Oil generally deteriorates the heat transfer coefficient of pure CO2. The reduction in heat transfer coefficient is most apparent at low vapor qualities, 0.1 to 0.4, and at low mass fluxes, 100 and 200 kg/m2. It is caused by the suppression of nucleate boiling due to increased surface tension. At conditions where the convective boiling contribution is dominant, vapor qualities above 0.5, oil increases heat transfer coefficients. Through visualization, it is shown that the wetted area on the perimeter of inner tube is enhanced due to formation of foaming in the smooth tube. However, such enhancement of heat transfer due to forming is negligible in the enhanced tube, because the enhanced factor due to micro-finned structures is dominant.


2017 ◽  
Vol 25 (03) ◽  
pp. 1750027 ◽  
Author(s):  
M. Mostaqur Rahman ◽  
Keishi Kariya ◽  
Akio Miyara

Experiments on condensation heat transfer and adiabatic pressure drop characteristics of R134a were performed inside smooth and microfin horizontal tubes. The tests were conducted in the mass flux range of 50[Formula: see text]kg/m2s to 200[Formula: see text]kg/m2s, vapor quality range of 0 to 1 and saturation temperature range of 20[Formula: see text]C to 35[Formula: see text]C. The effects of mass velocity, vapor quality, saturation temperature, and microfin on the condensation heat transfer and frictional pressure drop were analyzed. It was discovered that the local heat transfer coefficients and frictional pressure drop increases with increasing mass flux and vapor quality and decreasing with increasing saturation temperature. Higher heat transfer coefficient and frictional pressure drop in microfin tube were observed. The present experimental data were compared with the existing well-known condensation heat transfer and frictional pressure drop models available in the open literature. The condensation heat transfer coefficient and frictional pressure drop of R134a in horizontal microfin tube was predicted within an acceptable range by the existing correlation.


Author(s):  
Wei Li ◽  
Dan Huang ◽  
Zan Wu ◽  
Hong-Xia Li ◽  
Zhao-Yan Zhang ◽  
...  

An experimental investigation was performed for convective condensation of R410A inside four micro-fin tubes with the same outside diameter (OD) 5 mm and helix angle 18°. Data are for mass fluxes ranging from about 180 to 650 kg/m2s. The nominal saturation temperature is 320 K, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that Tube 4 has the best thermal performance for its largest condensation heat transfer coefficient and relatively low pressure drop penalty. Condensation heat transfer coefficient decreases at first and then increases or flattens out gradually as G decreases. This complex mass-flux effect may be explained by the complex interactions between micro-fins and fluid. The heat transfer enhancement mechanism is mainly due to the surface area increase over the plain tube at large mass fluxes, while liquid drainage and interfacial turbulence play important roles in heat transfer enhancement at low mass fluxes. In addition, the experimental data was analyzed using seven existing pressure-drop and four heat-transfer models to verify their respective accuracies.


Author(s):  
Ahmet Selim Dalkilic ◽  
Suriyan Laohalertdecha ◽  
Somchai Wongwises

This paper presents an experimental investigation on the co-current downward condensation of R134a inside a tube-in-tube heat exchanger. The test section is a 0.5 m long double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is constructed from smooth copper tubing of 9.52 mm outer diameter and 8.1 mm inner diameter. The condensing temperatures are between 40 and 50°C, heat fluxes are between 9.78 and 50.69 kW m−2. The temperature difference between the saturation temperature of refrigerant and inlet wall varies between 1.66–8.94°C. Condensation experiments are done at mass fluxes varying between 340 and 456 kg m−2s−1 while the average qualities are between 0.76–0.96. The quality of the refrigerant in the test section is calculated considering the temperature and pressure measured from the test section. The pressure drop across the test section is directly measured by a differential pressure transducer. The average experimental heat transfer coefficient of the refrigerant is calculated by applying an energy balance based on the energy transferred from the test section. Experimental data of annular flow are examined such as the alteration of condensation heat transfer coefficient with the vapor average quality and temperature difference respectively according to different mass fluxes and condensing temperatures. The relation between the heat flux and temperature difference, besides this, the relation between the condensation heat transfer coefficient and condensing pressure are shown comparatively and the effects of mass flux and condensation temperature on the pressure drop are also discussed. The efficiency of the condenser is considered comparing with various experimental data according to tested condensing temperatures and mass fluxes of refrigerant. Some well known correlations and models of heat transfer coefficient were compared to show that annular flow models were independent of tube orientation provided that annular flow regime exists along the tube length and capable of predicting condensation heat transfer coefficient in the test tube.


Sign in / Sign up

Export Citation Format

Share Document